CAUTION
Lab
el all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
1) Remove the fan assembly from the box and inspect
for any damage to the assembly. Contact your dealer or
courier if there is damage.
2) Remove the knock out at the bottom of the back
panel of the appliance by using a flat head screwdriver
as a lever, hook the tip of the screwdriver under the
panel beside the tabs and push the panel out.
3
) Install two (2) screws into the top two holes. Place
the blower assembly over these two (2) screws and
tighten. Install the two (2) bottom screws and tighten.
4) Plug the fan assembly in and check for proper
operation.
DO NOT
cut or remove the grounding prong from the plug.
DO NOT
route the power cord beneath the heater.
WARNING:
This appliance is equipped with a three-prong (grounding) plug for your protection against
shock hazard and should be plugged into a properly grounded three-prong receptacle.
w
iring
d
iagram
:
This is a basic wiring diagram for the
option fan installation.
1) Plug the fan assembly into a three-
prong (grounded) receptacle.
2) Turn the fan controller to the desired
setting.
3)
Once the unit has reached operating
temperature, the fan temperature sensor
will turn the fan on automatically.
4) When the unit cools down the fan
temperature sensor will shut the fan off
automatically.
Fan
White
Black
Fan
temperature
sensor
White
Black
Fan
controller
Power Supply
Installation
o
ptional
F
an
i
nstallation
:
This appliance when installed, must be electrically connected and grounded in accordance with local
codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part
1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI
/ NFPA 70 in the USA.
16