background image

11

Specifications

C

LEARANCES

 T

O

 C

OMBUSTIBLES

 - 1200 KI I

NSERT

:

A Minimum clearance to an unshielded side wall

10” (254 mm)

B Minimum  clearance  to  an  unshielded  8”  (203 

mm) mantel

21” (533 mm)

C Minimum  top  facing  (protruding  ¾”  [19  mm]) 

clearance

17½” (445 mm)

D Minimum side facing (protruding ¾” [19 mm]) 

clearance

1” (25 mm)

E

†  From  front  of  door  opening  to  edge  of  fl oor 
protection

USA 16” (406 mm)

CND 18” (450 mm)

F †  From  side/back  of  unit  to  edge  of  fl oor 

protection

USA 6” (152 mm)

CND 8” (200 mm)

† 

FLOOR PROTECTION: 

If unit is raised 0” - 2” (0mm-51mm); 1” (25mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised 2” - 8” (51mm-203mm); ½” (13mm) non-combustible material with k value = 0.84 or equivalent.
If unit is raised greater than 8” (203 mm) or more; any non-combustible material can be used.

Table 3: Reduction in (B) Minimum  Clearance from 1200 KI to  8” (203 mm) Mantel.

Type of protection

Modifi ed Clearance

A minimum of .013” (0.33mm) sheet metal spaced out 1” (25mm) by non-
combustible spacers. 

10½” (267 mm)

Ceramic  tiles,  or  equivalent  non-combustible  material  on  non-combustible 
supports and spaced out 1” (25mm) by non-combustible spacers. 

14” (357 mm)

Ceramic  tiles,  or  equivalent  non-combustible  material  on  non-combustible 
supports  with  a  minimum  of  .013”    (0.33mm)  sheet  metal  spaced  out  1” 
(25mm) by  non-combustible spacers. 

10½” (267 mm)

NOTES:

(1) Mantel protection must have at least 3” (75mm) edge clearance on all sides, except as provided in Note 4.
(2) If an adhesive is used to support non-combustible material, it shall not lose adhesive qualities at temperatures 
likely to be encountered and shall not contribute a signifi cant combustible load.
(3) Heat shield mounting hardware attached to combustible materials must be placed at the lateral extremities of 
the shield.
(4) Minimum clearance to unprotected walls and ceilings must be maintained.

Table 4: 1200 KI Insert Minimum Fireplace Size.

Masonry

Zero Clearance

Minimum Depth

13½” (343 mm)

14” (279 mm)

Minimum Width at back of fi replace

22⅜” (568 mm)

23” (584 mm)

Minimum Width at front of fi replace

27” (686 mm)

27¼” (692 mm)

Minimum Width at front of fi replace to include shroud

36” (915 mm)

36”  (915 mm)

Minimum Height

19¼” (489 mm)**

or 19¾” (502 mm)

20” (508 mm)

** 

If the masonry lintel height is only 19¼” (489 mm) to 19¾” (502 mm) refer to I

NSTALLATION

 - M

ODIFICATIONS

 F

OR

 

I

NSTALLATION

 

WITH

 19¼” (489 

MM

) H

IGH

 L

INTEL

 - I

NSERT

B

A

D

C

A

djac

en

t  w

all

F

E

Table 2: 1200 KI Insert Clearance to Combustibles.

Содержание 1200 KI FPI

Страница 1: ...HORITY HAVING JURISDICTION ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Tested Listed By Portland Oregon USA OMNI Test Laboratories Inc C O T L US Report 268 S 06b 2 THIS HEATER MEETS THE U S ENVIRONMENTAL PROTECTION AGENCIES EMISSION LIMITS FOR WOOD HEATERS SOLD AFTER JULY 1ST 1990 UNDER SPECIFIC CONDITIONS THIS HEATER HAS BEEN SHOWN TO DELIVER HEAT AT RATES RANGING FR...

Страница 2: ...rt 14 Installation 15 Removal From Pallet 15 Modifications For Installation with 19 483mm High Lintel 15 Masonry Fireplace Installation 16 Installation Using A Block Off Plate For USA Only 19 Model 1200 KI Brick Placement Tube Locations 21 Model 1700 KI Brick Placement Tube Locations 22 C Cast Ceramic Baffle Installation 23 Fan Wiring Diagrams 24 Fan Removal 24 Removal of Top 25 Installation Of The ...

Страница 3: ...e At least 12 square inches 77 4 cm2 of fresh outside air should be admitted into the room or directly to the stove through a 4 inch 10 16 cm diameter pipe Do not burn wet unseasoned wood this can causes excessive creosote accumulation When this is ignited it can cause a chimney fire that may result in a serious house fire Do not use grates andirons or any other methods to support or raise the fire u...

Страница 4: ...osition The center position is off When the switch is pushed down it is set to the automatic position 3 In the manual position the Rotary Rheostat knob is used to turn the fan on and off as well as adjust the flow 4 In the automatic position the fan will automatically turn on once the fan temperature sensor reaches the operating temperature When the unit cools down the fan temperature sensor will s...

Страница 5: ...your local fire authority will provide you with instructions to handle the situation 4 Once the fire is out examine the flue pipes chimney attic and roof of the house to see if any part has become damaged by the fire 4 Do not operate the stove again until the chimney and its lining have been cleaned and you are certain they have not been damaged We strongly recommend inspection by a WETT Wood Energy T...

Страница 6: ...add fuel to the stove fully open the damper by pulling it all the way to the right and slowly open the door This allows the chimney to carry away the additional smoke and keep it from entering the house b DO NOT OVERLOAD THE STOVE Normally three or four logs will provide heat for several hours There should never be any part of the stove glowing red hot when operating properly c DO NOT OVERFIRE If ...

Страница 7: ...570 KJ Kg but hardwood is generally more dense will weigh more per cord and burns a little slower and longer Cutting firewood so that it will fit horizontally front to back makes it easier loading and less likely for the fuel to roll on to the glass Except for a cold start there is no need to crisis cross the logs Ideal length for the logs used in the 1200 would be about 16 381 mm but it can burn pi...

Страница 8: ...the house known as negative pressure When a house experiences negative pressure the combustion gases can be drawn from the chimney and into the house This condition is commonly referred to as down drafting Increased amounts of insulation vinyl windows extra caulking in various places and door seals can all keep heat in but may also make a home too airtight An easy way to stop negative pressure in ...

Страница 9: ...ilot injection ports Slider plate used for air flow control Intake air Seasoned Firewood Exhaust Smoke 1 2 Ceramic baffle reflects heat down to burn the particles in the smoke Secondary air tubes creates a second burn on the particles in the smoke for a more efficient cleaner burn Convection Heat Radiant Heat Primary air window air wash cooler air to keep the glass clean Pilot air through Twin pil...

Страница 10: ... 1166 mm x 711 mm Oversized width x height 47 5 x 33 1207 mm x 838 mm Rating Label Location Side of Unit Behind Right Shroud 10 Specifications AIR CONTROL The amount of combustion air going to the air wash and pilot is controlled by the air control rod located on the right side of the unit To increase your air pull the rod out and to decrease push the rod in All Enviro wood stoves have a secondary...

Страница 11: ...on combustible spacers 14 357 mm Ceramic tiles or equivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible spacers 10 267 mm NOTES 1 Mantel protection must have at least 3 75mm edge clearance on all sides except as provided in Note 4 2 If an adhesive is used to support non combustible material it shall not lose ad...

Страница 12: ...on combustible spacers 16 408 mm Ceramic tiles or eqivalent non combustible material on non combustible supports with a minimum of 013 0 33mm sheet metal spaced out 1 25mm by non combustible spacers 12 305 mm NOTES 1 Mantel protection must have at least 3 75mm edge clearance on all sides except as provided in Note 4 2 If an adhesive is used to support non combustible material it shall not lose adh...

Страница 13: ...IMENSIONS 1200 KI INSERT Figure 4 1200 KI Insert Dimensions 28 1 4 715 46 1166 33 1 2 850 20 508 18 1 2 472 22 561 27 687 36 916 13 1 4 336 22 1 2 573 20 1 4 514 19 1 2 493 19 1 2 or 483 19 497 20 3 4 529 5 128 15 3 4 400 ...

Страница 14: ...ions DIMENSIONS 1700 KI INSERT 28 1 4 715 20 508 18 1 2 472 33 1 2 850 46 1166 20 3 4 526 19 1 2 or 483 19 497 24 607 17 3 4 450 27 686 20 1 4 515 5 126 36 916 22 561 27 687 14 Figure 5 1700 KI Insert Dimensions ...

Страница 15: ...ITH 19 484MM HIGH LINTEL Insert Cabinet Top Air Deflector Figure 9 Removing Air Deflector onto Cabinet Top Figure 8 Removing Cabinet Top from Unit The KI has a factory height of 19 496mm and it can be reduced to 19 483mm by modifying the cabinet top and mounting position Insert Unit 1 Remove the thirteen T 20 screws holding the cabinet top in place refer to Figure 8 2 Remove the cabinet top and flip...

Страница 16: ...ess steel liner that goes directly to the top of the chimney and is covered with a rain cap The chimney top is sealed with a flashing or steel plate that supports the weight of the chimney liner The installation must conform to the liner s manufacturer s instructions This fireplace must be installed with a continuous liner of 6 diameter CANADA ONLY extending from the fireplace insert to the top of th...

Страница 17: ...Figure 12 Insert Installation into existing floor level masonry fireplace Installation Floor Protection Combustible Floor Masonry Fireplace 8 203 mm USA 16 406 mm CND 18 450 mm Figure 11 Insert Installation into existing fireplace without hearth f Place the Collar Puller over the two bolts of the Flue Collar and pull it into place see Figure 14 Ensure that the bolts are to the left and right of the h...

Страница 18: ...e Let the silicon or cement dry 2 To make the installation of the surround panel onto the unit easy have the unit 6 150mm out from the fireplace 3 Push the insert into the fireplace allowing the insulation to form a seal between the panels and the fireplace Tuck any exposed insulation behind the face plate Figure 16 Installation with Surround Sealed Masonry Fireplace Mantel Damper Removed or Fastened...

Страница 19: ...e to the front of the fireplace opening Refer to Step 3 NOTE In general masonry fireplaces have square fireboxes while zero clearance metal fireplaces have domed firebox tops Therefore zero clearance block off plates may be more difficult to install Insulation may be used around the edges to simplify sealing the plate 2 Create a cardboard template of the dimensions with 2 51 cm wide flanges on each side ...

Страница 20: ...off plate Damper must be removed Zero clearance metal firebox IMPORTANT DO NOT modify any part of the ZC fireplace 7 After installing the unit into place and the pipe through the block off plate use high temperature fiberglass insulation and furnace cement to seal any gaps between the pipe and block off plate allow the cement to dry for at least 24 hours before burning Before starting this type of ...

Страница 21: ...he left until the right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Partial Brick Full Size Brick Tube A Tube E Tube D Full Size Brick Figure 21 Brick Placement for 1200 KI shown with Secondary Air Channel and Tubes 1 Place the three 3 full size bricks along each side of the fire...

Страница 22: ...il the right end of the tube is freed To installation a secondary air tube reverse the above instructions IMPORTANT All secondary air tubes must be in place for proper operation Full Size Brick Partial Brick Tube A Tube C Tube B Full Size Brick Full Size Brick Figure 22 Brick Placement for 1700 KI shown with Secondary Air Channel and Tubes 1 Place the four 4 full size bricks along each side of the...

Страница 23: ...rom the plug DO NOT route the power cord beneath the heater or away from the heat WARNING This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged into a properly grounded three prong receptacle 2 Hook the outside edge of the baffle over the top of the secondary air chamber This will make room to for the installation of the left C C...

Страница 24: ...2 T 20 screws mounting it to the firebox there are two hole in the cabinet side to access screws 2 Disconnect all electrical connections to the fan 3 Remove the four 8 32 X hex head screws that hold the fan mounting plate to the shroud 4 Remove the fan control knob and nut from the front of the shroud and pull the controls out the back 5 Install the fan kit into the new shroud by following reversin...

Страница 25: ...27 Installation of Surround Panel INSTALLATION OF THE SURROUND PANEL 1 You will need to remove the top as shown above before installing the surround panel 2 Once the top has been removed slide the surround panel over the unit 3 The surround will hook on to the side shrouds 4 Re install the top once the surround is in place ...

Страница 26: ...ON DU POELE DOIT SE FAIRE AVEC LA PORTE FERME N ouvrir la porte que pour alimenter le feu N utilisez que des combustibles solides Ne pas utiliser un autre type de carburant N employez pas de grille de foyer ou ne surélevez pas le Mettez le bois à brûler directement sur l âtre Pour éviter la surchauffeur ne mettez pas trop de bois N obstruez pas les ouv Mettez le bois à brûler directement sur l âtr...

Страница 27: ... Glass Retainer Kit With Screws 50 1122 17 1200 1700 Left Shield Assembly 50 1144 18 1200 1700 Right Shield Assembly 50 1145 19 1200 Ceramic Baffle L R Set 50 1146 20 1700 Ceramic Baffle L R Set 50 1147 21 FPI Flue Collar Assembly 50 1148 22 FPI Angled Flue Collar Assembly 50 1565 23 1200 1700 Ceramic Flue Gasket 50 1413 24 1200 1700 Cast Latch 50 1381 25 1200 1700 Insert Replacement Fan 50 2204 26 ...

Страница 28: ...28 Parts Diagram 20 31 14 15 17 28 21 23 18 30 33 34 26 27 8 10 11 32 6 16 7 1 2 3 29 4 5 25 22 19 12 13 24 9 35 ...

Страница 29: ...g serial number Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over firing due to incorrect setup or tampering Damage caused by incorrect installation To the Dealer Provide name address and telephone number of purchaser and date of purchase Provide date of purc...

Страница 30: ..._________________ _________________________________________ PHONE ___________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE ______________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy INSTALLER S SIGNATURE _________________________________________ NAME OF INSTALLER _________________________________________ ADD...

Отзывы: