Enviro Gas EG-40 FPI BV Скачать руководство пользователя страница 7

5. VENTING 

 

WARNING;

 THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR 

AND DILUTION AIR FROM THE ROOM. IT IS ALSO DESIGNED TO DRAW ROOM AIR FOR PROPER HEAT 

CIRCULATION FROM THE SIDES OF THE UNIT.  BLOCKING OR MODIFYING THE LOUVERS IN ANY WAY 

CAN CREATE HAZARDOUS SITUATIONS, EITHER THROUGH POOR VENTING OR BY OVERHEATING. IT 

IS IMPORTANT THAT THIS UNIT HAS SUFFICIENT AIR CIRCULATION FOR PROPER VENTING AND 

COMBUSTION.  PROVISIONS MUST BE MADE FOR THE SUPPLY OF ADEQUATE COMBUSTION AND 

VENTILATION AIR.  THESE OPENINGS MUST NOT BE BLOCKED. 

 

 

 

THE APPLIANCE MUST NOT BE CONNECTED TO A 

CHIMNEY FLUE SERVICING A SEPARATE SOLID FUEL 

BURNING APPLIANCE. 

 
VENTING FIREPLACE INSERTS 

 
The ENVIROGAS insert may be installed and vented into any 
solid fuel fireplace that has been installed in accordance with 
the National, Provincial/State and local building codes and has 
been constructed of non-combustible materials. 
 
An listed 4" chimney liner, seal plate, and rain cap must be 
installed, to ensure a tight seal, top performance, safety and 
efficiency. Carefully follow the chimney manufacturer’s 
instructions that accompany the liner kit. 
 
Measure the height of the chimney before hand and purchase 
the appropriate kit. Never attempt to over stretch a flexible 
liner to accommodate the height of the chimney. 
 
Install a seal plate to prevent leakage of room air through 
chimney. If the chimney is not sealed damage may occur to 
the appliance. 
  
Any flue damper must be removed or blocked permanently in 
the open position. 
 
The chimney must be clean, in good working order and 
constructed out of non-combustible materials. 
 
Make sure that all chimney clean outs are tightly fitting and will 
not permit air to leak into the chimney. 
 
Remove the vent collar plate from the top of the insert and 
connect it securely with at least 3 sheet metal screws and a 4" 

hose clamp. Check for any tears in the liner at this point. (See also Assembly and Installation Instructions section 
3.) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

Figure 7

 

 
IMPORTANT: Replace the screw that holds the vent collar plate in it's approved position. 
 
The draft hood must be in the same pressure zone as the air inlet. 
 
To inspect draft from the front of the unit, open right side hinged flap. Locate 3/8” tube and check for draft using 
smoke or magnehelic gauge. A vacuum will indicate proper drafting.

 

 

7

Содержание EG-40 FPI BV

Страница 1: ...switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depar...

Страница 2: ...installation must conform with local codes or in the absence of local codes with the current CAN CGA B 149 installation code in Canada or the National Fuel Gas Code ANSI Z223 1 2 in the USA To preven...

Страница 3: ...certified chimney liner kit Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bedsitting room Must be installe...

Страница 4: ...nected to the power supply Push the unit into its final position in the fireplace insuring that it is stable and level Using the leveling legs provided with the surround panel set 5 Reinstall the vent...

Страница 5: ...IONS A Depth of unit into fireplace 17 43 cm B Depth of unit out of fireplace 9 3 4 25 cm C Width of side panel 7 18 cm D Stove top to surround top 6 3 4 17 cm E Minimum firebox size W 36 x H 24 x D24...

Страница 6: ...cm minimum A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings Only permitted if verandah porch deck o...

Страница 7: ...fully follow the chimney manufacturer s instructions that accompany the liner kit Measure the height of the chimney before hand and purchase the appropriate kit Never attempt to over stretch a flexibl...

Страница 8: ...arge build ups Do not pack down leave embers loose Place cast ember pieces between the door facing and the ember tray The curved edge is placed into the firebox Align the mitered corner edges DO NOT P...

Страница 9: ...l electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the floor...

Страница 10: ...iance TO REPLACE DOOR AND GLASS ASSEMBLY The glass in this appliance is an integral part of the door assembly If the glass is damaged or broken a replacement door assembly including glass must be fitt...

Страница 11: ...t dealer Burners will not light when valve and burner switch are both on Defective switch check switch connections jump wires at switch Defective thermopile check connections to valve check voltage ac...

Страница 12: ...ode ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON CANADIAN STANDARDS ASSOCIATION RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap Mi...

Страница 13: ...ION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing WARNING Electrical grounding instruc...

Страница 14: ...12 mos 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burners Lift the tray out Remove the br...

Страница 15: ...line from the pilot assembly and remove the pilot injector Re install the pilot new pilot injector BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE DO NOT reu...

Страница 16: ...s only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under th...

Страница 17: ...me of Installer _________________________________________ __ Address _______________________________________ _________________________________________ __ _________________________________________ __ P...

Отзывы: