8. ROUTINE MAINTENANCE

 

 
Periodically check to ensure that the "B-Vent" venting 
system is clear and that a negative draft is present when 
the unit is operating. 
 
Periodically check the pilot and burner flames  
 

CLEANING OF GLASS 
 

Do not clean glass when hot

 

 
It will be necessary to clean the ceramic glass 
periodically.  During a cold start up condensation will 
sometimes form on the glass, this is a normal condition 
with all gas fireplaces and stoves. However, sometimes 
this condensation can allow dust and lint to cling to the 
glass surface. Also, sometimes the initial paint curing of 
the appliance can leave behind a slight film on the glass.  
This is a temporary problem. It is therefore 
recommended that the glass be cleaned initially after 
about the first two weeks of use. 
 
After that, depending upon the amount of use, cleaning 
should be required no more than two or three times per 
season. 
To clean the door, use a mild glass cleaner and a soft 
cloth.  Abrasive cleaners will damage the glass surface. 

 
OPENING THE GLASS DOOR

 

 
Turn unit off and wait until the appliance has cooled 
down. 
 
1.  Open the right hand hinged side flap that will expose 
a door fastener.  Using a 1/2" wrench, loosen off the 
fastener. 
 
2.  Due to the shape of the bay window door. You must 
also open the left-hand side flap before attempting to 
open the Bay window door. 
 
3.  Ensure the door is properly fastened after cleaning 
before attempting to re-light the appliance. 
 
4.  Remove all fingerprints from all gold before lighting 
this appliance. 

TO REPLACE DOOR AND GLASS 
ASSEMBLY 
 

The glass in this appliance is an integral part of the door 
assembly.  If the glass is damaged or broken a 
replacement door assembly including glass must be 
fitted. 

open door fully 

• 

Lift door vertically so that the hinge pins lift out of 
hinge receivers. 

• 

R

eturn assembly to dealer.

 

Your ENVIROGAS Dealer must replace door and glass 
assembly as a complete unit. No substitute materials are 
allowed

 

FOR CLEANING THE INSIDE OF THE 
FIREBOX 

 
Remove the log set carefully from the firebox.  Gently 
remove the embers and place on a piece of paper towel.  
Until ready to replace. 
 
Vacuum the firebox thoroughly.  Carefully clean off any 
dust on the logs and remove any lint from the main 
burner and pilot burner. 
 
After carefully replacing the logs and embers in their 
correct positions, and the door has been resealed, re-
light the pilot, following the instructions on the attached 
label. 

 

CLEARANCES MUST BE SUFFICIENT TO ALLOW 
ACCESS FOR MAINTENANCE AND SERVICE 
 

LUBRICATING THE BLOWERS

 

 

EVERY 6 MONTHS

 

 
1.  Turn the unit off and remove the log set.  
 
2.  Remove the burner tray assembly by removing the 
screw on either side of the tray, between the front and 
rear burners.  Lift tray out. 
 
3.  Remove the 8 screws that hold the blower mounting 
plate to the back firewall. 
 
4.  Carefully pull the blower assembly into the firebox, 
exposing the blower lubricating holes (located on the top 
of the motor housing on either side of the label).  Add 2 
drops of SAE 20 oil. 
 
If removal of the blower is necessary, disconnect the 2 
black blower leads from the terminal block, located on 
the floor of the fan compartment.  Remove the blower. 
 
5.  To re-install, check gasket and reverse steps 1 
through 4. 

 

 

10

Содержание EG-40 FPI BV

Страница 1: ...switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depar...

Страница 2: ...installation must conform with local codes or in the absence of local codes with the current CAN CGA B 149 installation code in Canada or the National Fuel Gas Code ANSI Z223 1 2 in the USA To preven...

Страница 3: ...certified chimney liner kit Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bedsitting room Must be installe...

Страница 4: ...nected to the power supply Push the unit into its final position in the fireplace insuring that it is stable and level Using the leveling legs provided with the surround panel set 5 Reinstall the vent...

Страница 5: ...IONS A Depth of unit into fireplace 17 43 cm B Depth of unit out of fireplace 9 3 4 25 cm C Width of side panel 7 18 cm D Stove top to surround top 6 3 4 17 cm E Minimum firebox size W 36 x H 24 x D24...

Страница 6: ...cm minimum A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings Only permitted if verandah porch deck o...

Страница 7: ...fully follow the chimney manufacturer s instructions that accompany the liner kit Measure the height of the chimney before hand and purchase the appropriate kit Never attempt to over stretch a flexibl...

Страница 8: ...arge build ups Do not pack down leave embers loose Place cast ember pieces between the door facing and the ember tray The curved edge is placed into the firebox Align the mitered corner edges DO NOT P...

Страница 9: ...l electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the floor...

Страница 10: ...iance TO REPLACE DOOR AND GLASS ASSEMBLY The glass in this appliance is an integral part of the door assembly If the glass is damaged or broken a replacement door assembly including glass must be fitt...

Страница 11: ...t dealer Burners will not light when valve and burner switch are both on Defective switch check switch connections jump wires at switch Defective thermopile check connections to valve check voltage ac...

Страница 12: ...ode ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON CANADIAN STANDARDS ASSOCIATION RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap Mi...

Страница 13: ...ION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing WARNING Electrical grounding instruc...

Страница 14: ...12 mos 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burners Lift the tray out Remove the br...

Страница 15: ...line from the pilot assembly and remove the pilot injector Re install the pilot new pilot injector BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE DO NOT reu...

Страница 16: ...s only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under th...

Страница 17: ...me of Installer _________________________________________ __ Address _______________________________________ _________________________________________ __ _________________________________________ __ P...

Отзывы: