SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY 
THIS MANUAL IS PRINTED ON RECYCLED PAPER

 

 
                  B y  

S H E R W O O D  

I N D U S T R I E S  

E G - 4 0   F i r e p l a c e   I n s e r t   V e n t e d   R o o m  

H e a t e r

 

O W N E R S   M A N U A L

 

 

Installation And Operating Instructions For Model:-

  

EG-40 FPI. BV.

 

 WHAT TO DO IF YOU SMELL GAS 

 Open windows/Extinguish any open flame 

 Do not try to light any appliance. 

 Do not touch any electrical switch; do not use any  

   phone in your building. 

 Immediately call your gas supplier from a  

   neighbor's phone.  Follow the gas supplier's  
   instructions. 

  If you cannot reach your gas supplier, call the fire  

   department.

 

WARNING

 

If the information in this manual 

is not followed exactly, a fire or 

explosion may result causing 

property damage, personal 

injury or loss of life. A qualified 
installer, service agency or the 

gas supplier must perform 

installation and service. 

PLEASE KEEP THESE OPERATING INSTRUCTIONS FOR FUTURE REFERENCE. 

Do not store or use gasoline or other Flammable vapors and liquids in the vicinity of this 

or any other appliance.

 

Содержание EG-40 FPI BV

Страница 1: ...switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire depar...

Страница 2: ...installation must conform with local codes or in the absence of local codes with the current CAN CGA B 149 installation code in Canada or the National Fuel Gas Code ANSI Z223 1 2 in the USA To preven...

Страница 3: ...certified chimney liner kit Has been certified for use with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bedsitting room Must be installe...

Страница 4: ...nected to the power supply Push the unit into its final position in the fireplace insuring that it is stable and level Using the leveling legs provided with the surround panel set 5 Reinstall the vent...

Страница 5: ...IONS A Depth of unit into fireplace 17 43 cm B Depth of unit out of fireplace 9 3 4 25 cm C Width of side panel 7 18 cm D Stove top to surround top 6 3 4 17 cm E Minimum firebox size W 36 x H 24 x D24...

Страница 6: ...cm minimum A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings Only permitted if verandah porch deck o...

Страница 7: ...fully follow the chimney manufacturer s instructions that accompany the liner kit Measure the height of the chimney before hand and purchase the appropriate kit Never attempt to over stretch a flexibl...

Страница 8: ...arge build ups Do not pack down leave embers loose Place cast ember pieces between the door facing and the ember tray The curved edge is placed into the firebox Align the mitered corner edges DO NOT P...

Страница 9: ...l electrical power to the appliance 3 Turn the gas control knob clockwise to the off position 4 Open door Wait five 5 minutes to clear out any gas Close door If you smell gas including near the floor...

Страница 10: ...iance TO REPLACE DOOR AND GLASS ASSEMBLY The glass in this appliance is an integral part of the door assembly If the glass is damaged or broken a replacement door assembly including glass must be fitt...

Страница 11: ...t dealer Burners will not light when valve and burner switch are both on Defective switch check switch connections jump wires at switch Defective thermopile check connections to valve check voltage ac...

Страница 12: ...ode ANSI Z223 1 UPON CONNECTION MARK APPROPRIATE FUEL TYPE ON CANADIAN STANDARDS ASSOCIATION RATING LABEL LOCATED ON THE INSIDE OF THE RIGHT HAND SIDE PANEL Manifold Pressure Tap Inlet Pressure Tap Mi...

Страница 13: ...ION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing WARNING Electrical grounding instruc...

Страница 14: ...12 mos 1 Turn the unit off and remove the log set 2 Remove the burner tray assembly by removing the screw on either side of the tray between the front and rear burners Lift the tray out Remove the br...

Страница 15: ...line from the pilot assembly and remove the pilot injector Re install the pilot new pilot injector BE CAREFUL WHEN TIGHTENING THE PILOT FITTING YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE DO NOT reu...

Страница 16: ...s only thereafter The paint on the Metal Brick Liner may peel This is due to the extreme conditions applied to the paint and is no way covered under warranty Your dealer shall make all claims under th...

Страница 17: ...me of Installer _________________________________________ __ Address _______________________________________ _________________________________________ __ _________________________________________ __ P...

Отзывы: