Chapter 6
Troubleshooting & Repairs
TABLE 6-1.
FLEX Error Messages
Error# Error Message
Cause
Troubleshooting
9009
Left Bin Door open
Safety breach!
RVM not operational Close
all Doors!
Left Bin Door is open.
Make sure that all doors are closed. If the
doors are closed, check the Diagnostic Pro-
gram (Main / Safety Loop) to see what is
causing this error.
9011
Right Bin Door open
Safety breach!
RVM not operational Close
all Doors!
Right Bin Door is open.
Make sure that all doors are closed. If the
doors are closed, check the Diagnostic Pro-
gram (Main / Safety Loop) to see what is
causing this error.
9014
Emergency cutout!
RVM not operational!
MC
1 triggered an emergency
shutoff.
9015
24
V
Power Fail
There is a problem with the
24
V
150
W
power supply in
the
RVM
Controller Box.
9016
Breaker Compactor1 triggered
RVM not operational Contact
Envipco Support
The Variable Speed Drive
for Compactor 1 went into
over- load and shut down
the
AC
compactor power.
If this error persists, there may be a
problem with the compactor or the
AC
motor.
9017
Breaker Compactor2 triggered
RVM not operational Contact
Envipco Support
The Variable Speed Drive
for Compactor 2 went into
over- load and shut down
the
AC
compactor power.
If this error persists, there may be a
problem with the compactor or the
AC
motor.
9018
Compactor 1 jammed
RVM not operational
Contact Envipco Support
The
RPM
sensor
on
compactor 1 detected that
the compactor stalled. It is
probably a jam.
Clear the compactor jam.
9019
Compactor 2 jammed
RVM not operational
Contact Envipco Support
The
RPM
sensor
on
compactor 2 detected that
the compactor stalled. It is
probably a jam.
Clear the compactor jam.
9022
No Printer Client RVM
not operational
Contact Envipco Support
The Printer Process is not
running on the
PC
board.
Check harnesses and connections. If
that fails, replace the
RVM
controller.
9023
No Display Client
RVM not operational
Contact Envipco Support
The Display Process is not
running on the
PC
board.
Check harnesses and connections. If
that fails, replace the
RVM
controller.
9024
Hardware Init
-> Emergency cutout
RVM not operational
Contact Envipco Support
MC
1 triggered the safety
inter- lock during hardware
initialization.
9025
Initialization failed
Make sure Sorter and Infeed are
free
RVM not operational
Contact Envipco Support
MC
5 initialization could not
complete for some reason.
Either the Sorting Cylinder
or In-Feed is jammed.
Clear any jams in the In-Feed or Sorting
Cylinder.
6-2
Содержание FLEX Dual
Страница 1: ...FLEX Series ServiceManual March 16 2016...
Страница 2: ......
Страница 14: ...1 6 Chapter 1 Introduction Safety FLEX HDS LASER DANGER LABEL...
Страница 19: ...1 11 Safety labels Intake Conveyor Side Glass Diverter FLEX DFF GSD ONLY FLEX DFF FLEX DFF GDS FLEX HDS 1 11...
Страница 21: ...1 13 Safety labels FLEX HDS ONLY RIGHT PANEL KEEP HANDS AWAY WARNING LABEL 1 13...
Страница 24: ...2 2 FIGURE 2 2 FLEXConfiguration Receipt Chute Payment Button Display In Feed Commodity Storage...
Страница 28: ...Chapter 2 Specifications 2 6 Notes...
Страница 38: ...Sensor Load Cell Camera Laser 3 6 FIGURE 3 9 Camera Laser LASER LINE GENERATOR CAMERA RVM CONTROLLER 3 10...
Страница 50: ...RVM Controller Box 3 19 FIGURE 3 18 MC5 BoardLayout FIGURE 3 19 MD5 BoardLayout 3 22...
Страница 57: ...3 26 Chapter 3 Hardware Components Notes...
Страница 58: ......
Страница 84: ...4 26 Chapter 4 RVM Software MC1 Board FLEX DFF FLEX DFF GDS AC MOTOR CONTROL BOX...
Страница 85: ...4 27 Software Theory of Operation Notes...
Страница 86: ...4 28 Chapter 4 RVM Software Notes...
Страница 94: ...5 8 Chapter 5 Maintenance Notes...
Страница 106: ...Chapter 6 Troubleshooting Repairs Notes 6 12...
Страница 107: ...Repairs Notes 6 13...
Страница 108: ...Chapter 6 Troubleshooting Repairs Notes 6 14...
Страница 109: ...Repairs Notes 6 15...
Страница 110: ...Chapter 6 Troubleshooting Repairs Notes 6 16...
Страница 111: ...Repairs Notes 6 17...
Страница 112: ...Chapter 6 Troubleshooting Repairs Notes 6 18...
Страница 113: ...Repairs Notes 6 19...
Страница 114: ...Chapter 6 Troubleshooting Repairs Notes 6 20...