Transportation humidity
5%
93%
Relative. Non-condensing at
30°C
The Solo and Solo XC nToken modules are designed to operate in
moderate climates only. Never operate the modules in dusty, damp, or
excessively hot conditions. Never install, store, or operate the Solo and
Solo XC nToken modules at locations where it may be subject to
dripping or splashing liquids.
2.5. Cooling requirements
Adequate cooling of the module is essential for trouble-free operation and a long
operational life.
During operation you can use the supplied
stattree
utility to check the actual and
maximum temperature of the module. It is advised to do this directly after installing the
module in its normal working environment. Monitor the temperature of the module over
its first few days of operation. If the module exceeds the safe operating temperature, it
stops operating and displays the
SOS-T
error message on the Status LED (see
2.6. Physical location considerations
Entrust nShield HSMs are certified to NIST FIPS 140-2 Level 2 and 3. In addition to the
intrinsic protection provided by an nShield HSM, customers must exercise due diligence
to ensure that the environment within which the nShield HSMs are deployed is
configured properly and is regularly examined as part of a comprehensive risk mitigation
program to assess both logical and physical threats. Applications running in the
environment shall be authenticated to ensure their legitimacy and to thwart possible
proliferation of malware that could infiltrate these as they access the HSMs’
cryptographic services. The deployed environment must adopt 'defense in depth'
measures and carefully consider the physical location to prevent detection of
electromagnetic emanations that might otherwise inadvertently disclose cryptographic
material.