Section 12
Configuration
56
Seam pulsation
Seam pulsation can be used in applications where a continuous weld is not required. The Main heat and the
Cool2 intervals are repeated for the duration of the weld. The following example shows how this type of sequence
may be implemented.
Parameter
Setting
Description
Sequence timing
Presqueeze
ms
The time for the electrodes to close onto the work piece.
Squeeze
ms
The time between the initial application of the electrode force
and the first application of welding current
Main heat
ms
The main welding current is applied
Cool2
ms
The material is allowed to cool with electrode force applied
Hold
ms
Electrode force continues after the welding current has
finished
Current control
Main mode
P/W – CCu – CCC Operating mode of the Main heat interval
Main heat
%
The % heat used during the Main heat interval
Main current
kA
The current used during the Main heat interval
Main monitor
1
yes/no
The current can be tested between limits
Low limit
1
%
Current low limit
High limit
1
%
Current high limit
Options
Pre-heat
no
Disable the Pre-heat parameters
Post-heat
no
Disable the Post-heat parameters
1
optional
Start input
1
EOS output
WAV output
Motor output
2
Force
Current
In
te
rva
l
S
q
ueez
e
Mai
n
heat
Cool
2
Mai
n
heat
Cool
2
Mai
n
heat
Cool
2
Mai
n
heat
Cool
2
Hold
1
The Main heat – Cool2 intervals are repeated until the Start input is removed.
2
The operation of the motor output is determined by the 2
nd
stage test (Section 12
Configuration
).
Содержание iPAK2
Страница 9: ...Section 1 Introduction 9 Communications Ethernet RS485 RS232...
Страница 11: ...Section 1 Introduction 11 Multi welder Up to 8 transformers and cylinders cascade or independent firing...
Страница 12: ...Section 1 Introduction 12 Seam welder with one transformer Seam welder with a multi tap transformer...
Страница 16: ...Section 2 Getting started 16 User s connections discrete...