Status information
iPAK2 reports a number of conditions to assist with diagnostics, quality control and maintenance. Each condition
corresponds to a code which is accessible via MODBUS.
Co
de
Condition
Action
0
Normal
1
Stop
Check the Stop input
2
Sync. error
Check 27 V ac sync signal and/or the Frequency parameter in Configuration
3
Retract not ready
Operate the Retract input
4
Inverter hot
Check inverter cooling
5
Transformer hot
Check weld transformer cooling
6
Pilot fault
Safety relay fault. Do not use the iPAK2 and return it for service.
7
Restart required
Restart the iPAK2
8
Headlocked
The welding head is locked because of a fault condition
9
Toroid short circuit Connection to Toroid (secondary feedback coil) is short-circuit
10
Toroid open circuit Connection to Toroid (secondary feedback coil) is open-circuit
11
Reserved
12
Reserved
13
Reserved
14
Reserved
15
Reserved
16
Test mode
For service use only
17
Start on
The Start input is on following a weld sequence or stop/power-up condition
18
Weld off
Check the Weld On input
19
Program inhibited
The selected weld program is inhibited
20
Output fault
One or more outputs have failed
21
Reserved
22
Too many links
Too many weld programs are linked together
23
Bad link
A link has been made to a weld program that cannot be used
24
Max. current
Check secondary circuit. Reduce heat/current.
25
Toroid overrange
Reduce current or use an external signal attenuator
26
CT overrange
Check calibration parameters
27
Max. pulse width
Check secondary circuit. Reduce heat/current.
28
Calibration error
Check parameters in calibration program
29
Reserved
30
Reserved
31
Reserved
32
Reserved
33
Low force
Check the analog input and output circuits and/or adjust force parameters
34
High force
Check the analog input and output circuits and/or adjust force parameters
35
Low pre-current
Check toroid feedback and/or adjust Pre-heat parameters
36
High pre-current
Check toroid feedback and/or adjust Pre-heat parameters
37
Low main current
Check toroid feedback and/or adjust Main heat parameters
38
High main current
Check toroid feedback and/or adjust Main heat parameters
39
Low post-current
Check toroid feedback and/or adjust Post-heat parameters
40
High post-current
Check toroid feedback and/or adjust Post-heat parameters
41
No 2
nd
stage
Check the 2
nd
Stage input
Содержание iPAK2
Страница 9: ...Section 1 Introduction 9 Communications Ethernet RS485 RS232...
Страница 11: ...Section 1 Introduction 11 Multi welder Up to 8 transformers and cylinders cascade or independent firing...
Страница 12: ...Section 1 Introduction 12 Seam welder with one transformer Seam welder with a multi tap transformer...
Страница 16: ...Section 2 Getting started 16 User s connections discrete...