7
IP2246EN
1
5
4
6
A
3
2
5
5
4
4.2 Standard installation
4.1 Maintenance
Ref.
Description
Cable
1
Transmitter
/
2
Flashing light
2 x 1mm²
Antenna (integrated in the flashing light)
coaxial 50 Ω
3
Key selector switch
4 x 0.5mm²
Digital combination wireless keypad
/
4
Actuator
2 x 1.5mm²
Actuator with limit switch
3 x 1.5mm²
5
Photocells
4 x 0.5mm²
6
Control panel
3G x 1.5mm²
A
Connect the power supply to a type-approved omnipolar switch, with a contact opening
distance of at least 3mm (not supplied).
Connection to the mains must be via an independent channel, separated from the
connections to the command and safety devices.
The control panel needs no special maintenance.
Make regular checks to ensure the good condition of the box seals and the electrical connections.