General accessories
Your EM SL can be further improved with the following add-ons (please contact your local Entrematic
Group dealer for detailed description).
Cover
Made in clear anodized aluminium as standard. Paint finished in RAL colours or anodizing optional.
Motion sensor and presence sensors
Add motion and presence sensors to improve comfort and safety.
Programme selectors
Electrical locks
The following locks are available to the operator:
•
Locked with power (LDP), fail safe
•
Locked without power (LD), fail secure
•
Bistable lock (LDB)
Manual unlocking device
For manual unlocking of the electrical lock, locked without power.
Micro switch kit, LSK/LIS
For indication of door and lock position.
Locked door indicator, LDI/LIS
For indication of locked lock and closed door for connection to alarm system.
Electrical emergency unit with batteries
Used if a door is required to be opened or closed by means of a rechargeable battery unit and remain
in this position in the event of power failure. Authorities can demand that the emergency units are
monitored on a regular time basis. Half an hour before this time has elapsed the following opening
impulse generates an emergency opening test. If there is no opening impulse within the next half
hour, the operator control unit generates the opening impulse itself.
If the battery opens the door within the limited time the test is successful and the door resumes the
function set by the programme selector.
Note! The test is never performed in programme selector setting OPEN. In setting OFF it can be se-
lected. The test is always performed after a RESET and after changing program selection, from a pos-
ition where a test is not done to a position where the test is a demand.
Electrical emergency unit with batteries and two motors
Used if a door is required to be opened by means of a rechargeable battery unit and remain in this
position in the event of power failure. Authorities can demand that the emergency unit is monitored
on a regular time basis. Half an hour before this time has elapsed the following opening impulse
generates an emergency opening test. If there is no opening impulse within half an hour, the oper-
ator control unit generates the opening impulse itself.
If the battery opens the door within the limited time the test is successful and the door resumes the
function set by the programme selector.
Note! The test is never performed in programme selector setting OPEN. In setting OFF it can be se-
lected. The test is always performed after a RESET and after changing program selection, from a pos-
ition where a test is not done to a position where the test is a demand.