Programme selectors
The door functions are set with different key programme selectors. The key must always be removed
on emergency escape doors after changing settings.
Surface mounted
PS-6
PSMB-5
PS-5M
Flush mounted
Programme selector functions
This function is only used on emergency escape doors after it is certain
that all people have left the building.
The door cannot be opened with inner and outer activation units. The
door is locked if an electromechanical locking device has been fitted. The
door can be opened partially with a key switch (if fitted). With an emer-
gency push-button (if fitted) the door opens fully.
OFF
Passage from inside only. The door is normally locked if an electromech-
anical locking device has been fitted. The door can only be opened with
the inner activation unit or with a key switch/emergency push-button (if
fitted).
EXIT
Two-way traffic, normal operation of the door. The door can be opened
with the inner and outer activation units and with a key switch/emergency
push-button (if fitted).
AUTO
Two-way traffic, AUTO PARTIAL is obtained. The door can be opened
partially with the inner and outer activation units and with a key switch
(if fitted). With an emergency push-button the door opens fully.
AUTO
PARTIAL
The door is permanently open. The door can be moved by hand e.g. for
window cleaning. All activation units except for the emergency push
button (if fitted) are disconnected.
OPEN
Set the programme selector to AUTO. Insert a narrow object in the small
hole on the programme selector and push briefly. The operator makes a
system test of the emergency unit (if selected), electromechanical lock,
watchdog relay and closed door position. The operator is after closing
reset and ready for normal operation.
RESET
Note! The RESET is not available on programme selector PS-5M.
Turn the key clockwise to the position “R” (six o’clock) and insert a narrow
object in the small hole on the programme selector and push briefly. Then
turn the key counter-clockwise back to the requested setting. The oper-
ator makes a system test of the emergency unit (if selected), electromech-
anical lock, watchdog relay and closed door position. The operator is after
closing reset and ready for normal operation.
RESET
Note! The key cannot be removed in the "R" position.
Note! If monitored emergency unit is a demand, a test of the emergency unit is performed when
the programme selector is turned from OFF or OPEN to any other position.
1005274-EMen-9.0
Issue 2019-06-28
8