General safety precautions

This installation manual is intended for professionally competent personnel 
only. Read the instructions carefully before beginning to install the product. 
Incorrect installation may be a source of danger. Packaging materials (pla-

stic, polystyrene, etc.) must not be allowed to litter the environment and must be 
kept out of the reach of children for whom they may be a source of danger. Before 
beginning  the  installation  check  that  the  product  is  in  perfect  condition.  These 
instruction must be kept and forwarded to all possible future user of the system.

EC declaration of conformity

The  manufacturer  Entrematic  Group  AB,  with  headquarters  in  Lodjursgatan 
10, SE-261 44 Landskrona, Sweden, declares that the safety device: SOF2M15-
SOF2M20-SOF2M25-SOF3M15-SOF3M20-SOF3M25 is compliant to the following 
European  directives  and  regulations:  Machinery  directive  98/37/CE;  EN12978, 
EN12453, EN12445;
EMC directive 2004/108/CE.
Landskrona, 2015-05-05 

 

 

        Marco Zini

 

 

 

 

                    (President & CEO

)

1. Technical data

Contact range 

 

 

0,5 A - 24 V~ / 

Temperature    

-10° C - +50° C

Stroke from contact to intervention 

max 15 mm

Stroke from intervention to mechanical stop 

max 40 mm

Opening time of contacts after intervention 

max 0,1 s

Recovery time from maximum deformation 

max 0,5 s

Maximum applicable force 

 

1 KN

Maximum speed of device  

 

0,25 m/s

Dimensions SOF2M15-SOF3M15   

30x1500x80 mm

Dimensions SOF2M20-SOF3M20   

30x2000x80 mm

Dimensions SOF2M25-SOF3M25   

30x2500x80 mm

Degree of protection

   

 

IP54

2. References (fig. 3)

[A]  Aluminium profile

[B]  Rubber

[C]  Steel wire
[D] Spring
[E]  Adjustment screw
[F]  Edge activation limit switch

[G]  Spring breakage limit switch

[H]  Position limit switch

3. Applications

The safety edge SOF2M-SOF3M is a safety device to be used only in systems with 
automatic doors and gates, to protect people from knocks and/or crushing.
Use  the  safety  edges  SOF2M-SOF3M  in  combination  with  DITEC  products,  and 

respect the instructions enclosed with each product.

4. Installation

(Fig. 4.1) Loosen the screw that fastens the upper lid, and remove the lid from 

the edge.

(Fig. 4.2) Loosen the screws that fasten the lower lid, and remove the lid from 

the edge.

(Fig. 4.3) Mark the position [S] of the upper side of the fastening slot on the 

side of the aluminium profile.

-   Arrange the edge in its final working position, and mark the reference position 

(noted earlier) on the destination surface. During the vertical assembly, keep 
a minimum distance of 30 mm from the ground, directing the device as shown 
in fig. 4.2.

-   (Fig. 4.4) Drill the edge support surface about 7 mm beneath the reference 

point, and fasten the spring with the appropriate elements (screw for metal, 
screw and anchor plug for walls).

-   Position the edge on the spring, 

and pull it downwards to con

-

nect it.

-   Mark the fastening holes on the 

wall, in line with points [C] and 

[D].

-   Remove  the  device  and  drill 

the  fastening  holes  marked 
previously.

-   Reconnect  the  device  to  the 

spring and fasten the screws.

-   Check the screw of the steel 

wire blocking terminal is well 

tightened.

(Only SOF3M) 

Check the rol-

ler on the lever is positioned 
on the central limit switch. If 

this  is  not  the  case,  loosen 
the  blocking  nut  and  adjust 

the position of the castor.

Connect a tester to the two terminals to check there is a continuous power 
supply.

-   Press the rubber edge to check the power supply is interrupted, then disconnect 

the tester.

-   Insert the lower lid in the notch, and fix it with the screws.

Drill the upper lid in the marked part.

-  Insert the electric wires, to be con-

nected to the control panel; fix them to 
the lid using a cable gland to ensure 
the degree of protection indicated 

(IP54). Connect them to the terminals 

then insert the lid and fasten it with 
the screw.

-  Check the intervention of the device 

when functioning with the control 
panel.
Note: the cables connecting the edge 

to the control panel must be positioned in ducts or casings so they are protected 
against mechanical damage. The equipment must be powered with a secure voltage 
(SELV or PELV).
The electric circuit at the source must be limited to a maximum current of 0.5 A.

5. Electrical connections

-    Connect the edges SOF2M to the card SOFA1 or SOFA2, as shown in fig. 1.
-    Connect the edges SOF3M as shown in fig. 2.
    Warning: if the control panel does not contain terminal 41, connect the edge 

to terminals 1-8 or 1-6 or 1-7 of the control panel.

6. Maintenance schedule

The regular maintenance must be carried out every 12 months by personnel with 
installation skills, and the following instructions must be observed.
-     Check the lids (upper and lower) and the aluminium support are not damaged 

or deformed; check the rubber part is not damaged or torn.

-     Disassemble the lid.
-     Check the steel wire is not damaged or frayed; replace the equipment if ne-

cessary.

-     Loosen the wire [C] and check that the spring [D] provokes the activation of the 

limit switch [G] (and the limit switch [H] in the case of SOF3M).

-     Tighten the wire [C] again, using the adjustment screw [E], and position the 

lever exactly in the middle between the limit switches [F] and [G] (check the 
correct activation of the limit switch [H] in the case of SOF3M).

-     Press the rubber [B] to check the correct activation of the limit switch [F] (and 

the limit switch [H] in the case of SOF3M).

-     Check the tightness of the electric connections with the terminals.
-     Connect a tester to the terminals and press the limit switches to check for 

correct functioning.

-     Reassemble the lid.

All the rights concerning this material are the exclusive property of Entrematic 
Group AB. Although the contents of this publication have been drawn up with the 
greatest care, Entrematic Group AB cannot be held responsible in any way for 
any damage caused by mistakes or omissions in this publication.
We reserve the right to make changes without prior notice. Copying, scanning 
and changing in any way are expressly forbidden unless authorised in writing by 
Entrematic Group AB.

ENGLISH

Содержание Ditec SOF2M

Страница 1: ...hldraht SOF2M SOF3M Manual de instalaci n para burlete de hilo de acero SOF2M SOF3M Manual de instala o para borracha com fio de a o SOF2M SOF3M www ditecentrematic com CONTROL PANEL SOF2M15 SOF2M20 S...

Страница 2: ...2 IP2058 2015 05 12 1 4 2 3 Fig 4...

Страница 3: ...a Riagganciare il dispositivo sulla molla e procedere con il fissag gio delle viti Verificare che la vite del mor setto di bloccaggio cavo in acciaio sia serrata con forza Solo SOF3M Controllare che i...

Страница 4: ...d drill the fastening holes marked previously Reconnect the device to the spring and fasten the screws Check the screw of the steel wire blocking terminal is well tightened Only SOF3M Check the rol le...

Страница 5: ...f et effectuer des trous de fixation pr c dem ment marqu s Raccrocher le dispositif sur le ressort et fixer les vis V rifier que la vis du bornier de blocage c ble en acier soir serr fortement Seuleme...

Страница 6: ...r einh ngen und mit der Befestigung der Schrauben fortfahren Sicherstellen dass die Schraube der Befesti gungsklemme des Stahlka bels fest angezogen ist Nur SOF3M Sicherstellen dass die Rolle auf dem...

Страница 7: ...fijaci n marcados precedentemente Vuelva a enganchar el disposi tivo en el resorte y proceda a la fijaci n de los tornillos Compruebe que el tornillo del borne de bloqueo cable de acero est apretado c...

Страница 8: ...ositivo e realizar os orif cios de fixa o marca dos anteriormente Engatar novamente o dispo sitivo na mola e realizar a fixa o dos parafusos Verificar que o parafuso do prensador de bloqueio do cabo e...

Отзывы: