- 34 -
0DT828 2014-06-13
1 2 3 4 5 6
ON
49E
Trimmer
Description
TC
Setting automatic closing time. From 0 to 30 s.
Note: after the activation of the stop command, once contact 1-9 has closed again, the
automatic closing is only activated after a total, partial or step-by-step opening command.
RP
Motor partial opening adjustment. From 0 to 30 s.
Jumpers
Description
OFF
ON
SO
Reversal safety switch
function.
With the automation blocked, if the
contacts 41-8 are open, it is possible to
activate the opening operation.
With the automation blocked, if
the contacts 41-8 are open, any
operation is impossible.
EO
Electric brake.
Do not use
Normal.
0 s
30 s
0 s
30 s
SIGNALS AND SETTING
Button
LED
Starts the opening operation.
The green LED on indicates the presence of the 24 V=power supply.
Starts the partial opening operation.
Starts and stops the STOP operation. the red LED on indicates that the STOP has been activated.
the flashing red LED indicates that the safety devices have been activated.
Starts the closing operation.
ON
Dip - switch
Description
OFF
ON
DIP 1
Control 1-3 function.
Step-by-Step
Opening
DIP 2
Restore automatic closing
time.
Do not use
100 %
DIP 3
Preflashing set at 3 s.
Disabled during
opening
Enabled for both
opening and closing
DIP 4
Application type.
Do not use
Rapid door
DIP 5
Dynamic brake.
Disabled
Do not use
DIP 6
Double speed
Disabled
Do not use
LED
On
Flashing
POWER
24 V= power supply.
/
SA
Indicates that at least one of the safety
contacts is open. ( 6 - 8 - 9 )
- Indicates the STOP operation activated by pushbutton panel
PT4 (if present).
- If the AUTOTEST device is installed, this indicates a safety
test failure (terminal 41).
- On power on, the LED flashes to indicate the number of
operations performed:
each rapid flash = 10000 operations
each slow flash = 100000 operations
IN
Activated at every command and
adjustment to the dip-switch and jumper.
/
11
Indicates that the 0-11 limit switch
contact is open.
/
12
Indicates that the 0-12 limit switch
contact is open.
/
17
Indicates that the 0-17 limit switch
contact is open.
(not used)
/
Ditec Energy
Dip-switches
setting
Содержание Ditec Energy 0DT828
Страница 22: ... 22 0DT828 2014 06 13 ...
Страница 25: ...MECHANICAL INSTALLATION DRAWINGS 15 3 4 C T C T 200mm 14 6 5 WIND WIND A B 7 365 8 STOP 0 COM C NO DS 10 ...
Страница 27: ......
Страница 48: ...Entrematic Group AB Lodjursgatan 10 SE 261 44 Landskrona Sweden www ditecentrematic com 0DT833 2014 06 13 ...