Installing Options into the 6G306-06
Installation
3-5
Figure 3-3
Installing a Side Clip GPIM into the Module
3.2.1.2
Removing the Side Clip GPIM
Remove a GPIM from its slot in a module as follows:
1.
Attach the antistatic wrist strap (refer to the instructions in the antistatic wrist strap package)
before removing the GPIM.
2.
Remove any cables connected to the GPIM.
3.
Locate the locking tabs that are on the side of the GPIM. See
Figure 3-3
.
4.
Squeeze both locking tabs in towards the center of the GPIM. This will unlock the GPIM clips.
5.
Grasp the sides of the GPIM while squeezing the tabs and pull it out of the port.
6.
If storing or shipping the GPIM, insert the dust protector into the GPIM to protect the fiber ports.
CAUTION:
Do NOT remove a GPIM from a slot without unlocking the tabs. This can
damage the GPIM.
The GPIM and the module are sensitive to static discharges. Use an antistatic wrist
strap and observe all static precautions during this procedure. Failure to do so could
result in damage to the GPIM or module. Always leave the GPIM in the antistatic bag or
an equivalent antistatic container when not installed.
Network Port
20-pin Connector
(insertion end)
2549_05
Locking Tab
Locking Tab
(hidden from view)
RX
TX
Top of GPIM
Hinge Side
of Door
1
2