Using LANVIEW
Matrix DFE-Platinum Series Module Installation Guide 4-3
CPU
None
Power off.
Ensure chassis has adequate power.
Amber
Blinking
. Module in process of
booting.
None.
Solid
. Testing.
If the LED remains amber for several
minutes, contact Enterasys Networks for
technical support.
Green
Blinking
.
Image starts running.
None.
Solid
. Functional.
None.
Red
Solid
. Processor in reset.
None.
Green
and
Amber
Blinking
.
Indicates that the
DFE-Diamond module is in the
process of shutting down.
None. This state is activated when the
OFFLINE/RESET switch is pressed for less
than 1 second to a start the process of an
orderly shutdown.
While in this state, do not remove any
DFE-Diamond module.
Amber
and off
Alternate (67% on, 33% off)
.
Indicates that a shutdown
process has completed. This
indication will remain for 60
seconds before automatically
restarting.
While in this state, you have 60 seconds to
safely remove the DFE-Diamond module
from the chassis.
RX
(Receive)
None
No link
. No activity. Port
enabled or disabled.
None.
Green
Solid
. Link present, port
enabled, no traffic is being
received by the interface.
None.
Amber
Flashing
. Link present, port
enabled, traffic is being received
by the interface.
None.
TX
(Transmit)
None
Port enabled, but no activity.
If it is known that the port should be
transmitting and is not, contact
Enterasys Networks for technical support.
Green
Flashing
. Indicates data
transmission activity. Rate of
flashing indicates the data rate.
None.
Table 4-1 LANVIEW LEDs (Continued)
LED
Color
State
Recommended Action
Содержание Enterasys Diamond Distributed Forwarding Engine 7KR4297-02
Страница 2: ......
Страница 42: ...Completing the Installation 3 20 Installation ...
Страница 50: ...Overview of DFE Diamond Module Shutdown Procedure 4 8 Troubleshooting ...
Страница 62: ...Memory Locations and Replacement Procedures B 8 Mode Switch Bank Settings and Optional Installations ...