Connecting to the Network
6E128-26, 6E138-25, 6E129-26 and 6E139-25 User’s Guide
3-7
4.
At the other end of the fiber optic cable, attach the fiber pair to the
transmit and receive ports of the device.
.
Figure 3-2
Fiber Optic Connection
5.
Verify that a Link exists by checking that the port RX LED is on
(flashing amber, blinking green, or solid green). If the RX LED is off,
perform the following steps until it is on:
a.
Verify that the device at the other end of the segment is ON and
connected to the segment.
b.
Check the crossover of the cables. Swap the cable connections if
necessary.
c.
Check the cable for continuity.
d.
Check that the fiber optic connection meets the dB loss and cable
specifications outlined in
Chapter 2
.
If a link is not established, contact Cabletron Systems Global Call Center.
Refer to
Section 1.7
, for details.
6.
Repeat steps 1 through 5, above, until all connections have been made.
17
Receive (RX) LED
231103
Содержание 6E128-26
Страница 2: ...9032311 03 ...
Страница 12: ...Contents x 6E128 26 6E138 25 6E129 26 and 6E139 25 User s Guide ...
Страница 38: ...Chapter 3 Installation 3 12 6E128 26 6E138 25 6E129 26 and 6E139 25 User s Guide ...
Страница 46: ...Chapter 4 Troubleshooting 4 8 6E128 26 6E138 25 6E129 26 and 6E139 25 User s Guide ...
Страница 164: ...Appendix A Specifications A 4 6E128 26 6E138 25 6E129 26 and 6E139 25 User s Guide ...
Страница 168: ...Appendix B FE 100TX FE 100FX and FE 100F3 Specifications B 4 6E128 26 6E138 25 6E129 26 and 6E139 25 User s Guide ...