15
TIME
The TIME potentiometer enables the length of time the light
remains on after the sensor’s last reaction to movement to be
adjusted. The horizontal arrow points to 3 minutes (time after last
movement). The setting range is 3 min - 30 min.
7. MAINTENANCE AND TROUBLE-SHOOTING
Should problems arise with the light fi tting’s operation, turn off the power for a few moments,
then recheck the operation. Check also that the lamps are fi xed securely in their lamp holders.
If this has no effect, change the lamps. Check also the securing of the wires to the terminal
block.
Always switch off the power before changing lamps! If the lamp has been changed
while the power is on, switch off the power for at least 30 seconds after changing the
lamp.
After an interruption in the power supply there will be a self-test. Detecting the
fault, the PIR sensor’s red LED will fl ash alternately bright and dim.
If the PIR sencor fails
to work though the power supply is on, switch off the power supply before removing the
PIR sensor from the light fi tting and sending it for replacement.
8. CLEANING
The lens should be cleaned when necessary using a damp cloth. Do not use cleaning agents
or solvents as these may damage the lens surface!
9. TECHNICAL SPECIFICATIONS
· Minimum mounting height: 1.7 m.
· Features a Passive Infra Red sensor unit (PIR).
· Power supply: 220 - 240 V, 50 / 60 Hz
· Detection area:
horizontally 180°
vertically 45° (from horizontally down 5°...50°)
· Detection area: forwards 11 m, both sides 12 m.
· Adjusting detection area: vertically 45°, from horizontally down
· Sensitivity (within detection range) SENS, illumination level LUX (1 lx - infi nity) and
TIME setting
· Switch off 3 - 30 min after movement ceases (TIME setting).
·
AVR72...4E:
electronic ballast , starting time 1 - 2 sec.
· Max. external load: 400VA fl uorescent lamps or 400W incandescent lamps.
· Operating temperature:
incandescent lamp models -30 °C ...+ 30 °C
E models - 15 °C ... + 25 °C
· Operating modes: automatic operation in dusk, test mode and lux setting mode
· Enclosure class: IP 44
· Insulating class: II
PXA 54
LUX
LUX: 1lx - , TIME: 3-30 min
220-240VAC 50/60Hz
IP44
CCA
06
TIME