the moving components and resonance is reduced to a minimum level. If 

excessive noise or vibration is experienced, reverse the movement action 

(up or down) of the base with the remote control. This should realign 

the base’s activating mechanisms to the proper operational position.  In 

normal base operation, the wheels, which allow the bed to maintain its 

distance from the wall, will make contact with the steel platform supports 

of the base creating a contact noise. When entering, exiting or shifting 

weight on the base, this contact noise may be audible as the wheels make 

contact. This is normal.

MATERIALS

Enso adjustable bases are constructed from various materials including 

woods, metals, plastics and fabrics. Tension, pressure or movement 

applied to the frame, platform or shroud through general use may create 

an audible sound.

 

MASSAGE OPERATION AND LOCATION ENVIRONMENT

The massage feature will emit a tone during operation. This is normal. 

As the massage intensity level is increased, the tone will intensify. The 

volume of this tone is directly related to the location environment. 

For example, when demonstrated in a show room, the surrounding 

environmental noise will cover some of the massage noise. However, 

when installed in a home setting with wooden floors, carpeted or not, 

the massage volume will be more noticeable. To minimize this resonance, 

place a piece of carpet, or rubber caster cups, under each leg or caster of 

the base.  It is possible to experience vibration or noise from the exterior 

bed frame, headboard brackets, headboards or footboards if mounting 

bolts are not firmly tightened.

Levels 1-6 of massage intensity represent the revolutions of the motor 

per minute. Level 6 provides the maximum number of RPMs.  However, 

this does not mean that the feeling of vibration is the strongest.  

Depending on the mattress material, thickness, and positioning of the 

user, the feeling of vibrations will differ. We encourage the user to find 

the massage intensity setting that suits them best. It is important to 

understand the physics of vibrations. Just as an engine may run rough 

during idle, as the RPMs increase, the vibrations change concurrently.  

 

TOLERANCE

All Enso adjustable foundations, depending on make and model, are 

designed and manufactured to perform and function within designated 

quality control parameters. Bases are subject to meticulous and rigorous 

inspections during the quality control process to ensure bases will operate 

within these standards during normal operating use. Normal operating 

use is defined as the following: Adjustable foundation is to be operated 

with a mattress and load. Testing procedures require lifetime cycle tests 

with up to 120kg distributed load. The angle (designated “

α

” in figure 1) 

between the back section and the flat 

section for various configurations of the 

mattress support platform shall be ± 3°, 

which translates to a tolerance of up to 

1 ½”.

The angle (designated “

β

” in figure 1) 

between the flat section and foot section 

for various configurations of the mattress 

support platform shall be ± 3°, which translates to a tolerance of up to ¾”. 

Any adjustable foundation deemed to be within these allocated 

tolerances is considered to have met the manufacturer’s quality control 

standards.

THAT “NEW PRODUCT” SMELL:

Some people notice a slight odor to their new adjustable base—this can 

come from our material manufacturing process. This smell is normal and 

usually disappears before the product reaches you. Sometimes, however, 

this smell may still be noticeable. It usually disappears after a few weeks, 

providing adequate ventilation of the product and the environment.

safety precautions and usage statements

Adjustable

Bed Tolerance

Ergomotion Inc.

 

|

 ph 1-888-550-3746 

|

 fx 805-979-9399 

|

 www.ergomotion.

com

All Ergomotion adjustable foundations, depending on make and model, are designed and manufactured to perform and 

function within designated quality control parameters.   Bases are subject to meticulous and rigorous inspections during 

the quality control process to ensure bases will operate within these standards during normal operating use.

Normal operating use is defined as the following:

-Adjustable foundation is to be operated with a mattress and load.  Testing procedures require lifetime cycle 

 tests with up to 120kg distributed load.

The angle (designated “

α

” in figure 1) between the back section and the flat section for various configurations of the 

mattress support platform shall be ± 3°, which translates to a tolerance of up to 1 ½”.

The angle (designated “

β

” in figure 1) between the flat section and foot section for various configurations of the mattress 

support platform shall be ± 3°, which translates to a tolerance of up to ¾”.

Any adjustable foundation deemed to be within these allocated tolerances is considered to have met the manufacturer’s 

quality control standards.

(α°) 

(β°)

When operating a "paired" split base setup there may be a time latency up to 1.5 seconds between each bases articulation.

Blake Pettit

Quality Assurance Manager

Ph 805-979-3875

Fx 805-979-9399

www.ergomotion.com

Содержание PB275

Страница 1: ...Actual product appearance and functionality may vary from photographs illustrations and descriptions included in this manual OWNER S MANUAL PB275...

Страница 2: ...autions and Usage Statements 1 3 Parts List 4 Base and Remote Overview 5 Quick Reference Guide 6 Installation Guide 7 8 Connecting Strap 9 Syncing Two Bases 10 Headboard Brackets 11 Troubleshooting 12...

Страница 3: ...r under the bed Children should not operate the bed base without adult supervision PACEMAKERS Some products contain Neodymium MAGNETS which may interfere with devices such as pacemakers ICD s and any...

Страница 4: ...ol process to ensure bases will operate within these standards during normal operating use Normal operating use is defined as the following Adjustable foundation is to be operated with a mattress and...

Страница 5: ...visible after cleaning seek professional advice PRODUCT RATINGS The lift motors are not designed to operate continuously for more than 2 minutes in an 18 minute time period or approximately 10 duty c...

Страница 6: ...or Headboard Bracket Components optional I Headboard Bracket 2 J T Bracket 2 K Spacer 2 L Long Bolts 8 M Short Bolts 10 N Nuts 18 These items are attached to the base for shipping purposes Carefully r...

Страница 7: ...view Head Motor Lowers foot portion of the base Lifts head portion of the base Lifts foot portion of the base Lowers head portion of the base Lower head and foot simultaneously Raise head and foot sim...

Страница 8: ...illustration purposes only Read all instructions before beginning installation ELECTRONICS OVERVIEW If installing a split unit see page 10 Power Cord Power Supply Power Connection Cord Head Motor Foot...

Страница 9: ...or 6 inch leg install 3 inch leg 6 inch leg STEP 1 STEP 2 With the help of an able bodied assistant place the carton on the floor with the arrows pointing downwards Remove the binding straps and packi...

Страница 10: ...e to a flat position before placing the mattress on top Setup is now complete Test all functions on remote Slide the left side of the mattress retainer bar into the bracket Pull the retainer bar to th...

Страница 11: ...strap and connect side b to the leg bolt Secure the strap by shifting to the left Re tighten legs Do not over tighten Use the remaining strap and repeat on other end of the base STEP 2 STEP 1 STEP 3 c...

Страница 12: ...y cord into wired remote port that is connected to the head motor Repeat for other end of cord and second base Once the remote has been connected to the wired remote port with the y cord plug bases in...

Страница 13: ...e the headboard secure and tighten the bolts nuts and washers a b a b STEP 2 Attach the plastic spacer and T Bracket a Measure the distance between the mounting holes on the headboard and install the...

Страница 14: ...ower cords are properly connected Unplug the base for 1 hour to reset the electronic components Plug bed base into a different electrical outlet or test current outlet with another working appliance a...

Страница 15: ...mo el movimiento ejercicio Esto es una ocurrencia com n con cualquier producto que crea un movimiento de vibraci n y puede no afectar el marcapasos Por favor consulte a su m dico antes de usar la func...

Страница 16: ...a cama ajustable a trav s de actividades como leer ver la televisi n o jugar con los ni os o nietos El movimiento adicional ayudar a la base ajustable de responder a los cambios de temperatura y peso...

Страница 17: ...vemente Limpie con una tela limpia y mojada con la agua tibia para quitar el residuo Es importante de Secar bajo sombra y lejos del calor Si las marcas spermanecen visibles despu s de la limpieza busc...

Страница 18: ...ti ndala desde la base Verifique que la fuente de energ a y todos los cables relacionados con sta vayan directamente hacia el protector de sobrecargas deseado Pg 8 Gu a de instalaci n PASO 7 Con cuida...

Страница 19: ...deber 2 tornillos largos y 2 tuercas Coloque el espaciador y la placa de fijaci n en la ubicaci n deseada y el deslizamiento de los pernos a trav s de los agujeros con la cabeza del perno hacia afuera...

Страница 20: ...mes de l h pital Ne pas utiliser cette base avec le type de caravane quipement de th rapie d oxyg ne ou proximit de gaz explosifs CARACT RISTIQUES DE S CURIT SUPPL MENTAIRES Roues jambe accessoire en...

Страница 21: ...n nettoyage plus approfondi les d versements de liquides secs avec un chiffon propre et sec Essuyez avec un chif fon propre humidifi avec de l eau ti de Non d tremper Une brosse poils doux peut tre ut...

Страница 22: ...ote Control T l commande filaire 1 B Mattress Retainer bar Barre de soutiens du matelas 1 C Legs Pieds 6 D Power Cord Cordon d alimentation 1 E Power supply Alimentation lectrique 1 F Y Cord Cordon en...

Страница 23: ...le moteur de t te sous la base Brancher fin y cordon dans le port distant c bl qui est connect au moteur de la t te R p tez l op ration pour l autre extr mit du cordon et la deuxi me base TAPE 3 Conn...

Страница 24: ...Nationwide Customer Service Phone 1 844 534 3676 Fax 1 805 979 9399 Email info ergomotion com Web www ergomotion com 2016 Ergomotion Inc V001_07 2016 Serial Number...

Отзывы: