Specifications 

Technical data 

Height adjustment 

ca. 48 - 101 cm 

Length 

ca. 207 cm 

Width 

ca. 67 cm 

Lifting capacity 

150 kg for the electrical model 
150 kg for the hydraulic model 

Motor speed 

6 mm/sec 

Mains voltage 

230V~ 50/60 Hz 

Current consumption 

1.0 A 

Applied part 

Type B: tabletop 

IP classification 

IPX0 (treatment couch) 

Upholstery 

Type AKV Peri 

Fire safety 

DIN EN 1021 part 1/2 

Free of phthalates 

yes 

Biological 

DIN EN ISO 10993-5 
DIN EN ISO 10993-10 

 
Technical modifications reserved! 

 

Safety and performance standards 

This equipment complies with all requirements of the Medical Device Regulation (EU) 2017/745. 
Medical device classification 

Safety class according to IEC 60601-1 

  II, double insulated 

Type B Applied part 

 

Environmental conditions 

Environmental conditions for transport and storage 

Environmental temperature 

-40° to +70° C 

Relative humidity 

10 to 90% (non-condensing) 

Atmospheric pressure  

500 to 1060 hPa 

 

Environmental conditions normal use 

Environmental temperature 

-10° to 40° C 

Relative humidity 

30 to 70 % (non-condensing) 

Atmospheric pressure 

700 to 1060 hPa 

 
 
 

 

 

Содержание Manumed ST

Страница 1: ...Manumed ST EN109 1560750 44 APRIL 4 2022 Instructions for use...

Страница 2: ...3 2 Symbols 3 3 Package contents 4 4 Installation 5 5 Intended use and intended user 5 6 Precautionary instructions 6 7 Operation 7 8 Safety instructions 9 9 Cleaning maintenance and troubleshooting...

Страница 3: ...o Manumed ST 2 section head section Manumed ST 2 section back section Manumed ST 3 section Manumed ST accessories 2 Symbols Symbol used Description Follow the instructions in the Instructions for Use...

Страница 4: ...d water by mechanical casings and electrical enclosures Double Insulation Type B applied part complying with the specified requirements to provide protection against electric shock particularly regard...

Страница 5: ...d ST should be placed on a flat surface Turn the adjustable foot until it touches the ground and the couch is standing stable For correct assembly and safe use of possible optional accessories one mus...

Страница 6: ...nt to be used by competent personnel in physiotherapy rehabilitation or adjacent areas Avoid any use of the equipment by unauthorized personnel When used by children supervision by a knowledgeable par...

Страница 7: ...upports the full weight of the patient Each section of this Manumed ST is supported by gas springs As well as easing operation they offer full support of the sections However these gas springs are not...

Страница 8: ...ed underneath the framework with your foot the required height of the couch can be set At the head section of the couch the height can be adjusted by turning the handle to the left or to the right Nev...

Страница 9: ...eside the couch is set in flexion position combined with the lowest possible position Underneath the head section between the head section and floor Danger of tilting Do not sit on the head and leg se...

Страница 10: ...clean water Disinfection Clean the couch as described above before proceeding to disinfect the couch Follow the disinfectant s instructions for use Never use a mixture of disinfectants or a disinfecta...

Страница 11: ...service life This device will remain suitable for its intended use as long as it is subjected to yearly maintenance by a qualified service engineer as described in the service manual and the service...

Страница 12: ...EN ISO 10993 5 DIN EN ISO 10993 10 Technical modifications reserved Safety and performance standards This equipment complies with all requirements of the Medical Device Regulation EU 2017 745 Medical...

Страница 13: ...rs be liable for any indirect special incidental or consequential damages arising from the use of or inability to use the product including without limitation damages for loss of goodwill work and pro...

Страница 14: ...EN109 1560750 44 Copyright Enraf Nonius B V Vareseweg 127 3047 AT Rotterdam The Netherlands Tel 31 0 10 20 30 600 info enraf nonius nl...

Отзывы: