background image

S

tandard

 t

ermS

 

and

 C

onditionS

Q

uinCy

 C

ompreSSor

 

and

 o

rtman

 F

luid

 p

ower

 d

iviSionS

TITLE & LIEN RIGHTS: The equipment shall remain personal property, regardless of how affixed to any 

realty or structure.  Until the price (including any notes given therefore) of the equipment has been fully 

paid in cash, Seller shall, in the event of Buyer’s default, have the right to repossess such equipment.
PATENT INFRINGMENT: If properly notified and given an opportunity to do so with friendly assistance, 

Seller will defend Buyer and the ultimate user of the equipment from any actual or alleged infringement of 

any published United States patent by the equipment or any part thereof furnished pursuant hereto (other 

than parts of special design, construction, or manufacture specified by and originating with Buyer), and will 

pay all damages and costs awarded by competent court in any suit thus defended or of which it may have 

had notice and opportunity to defend as aforesaid.
STANDARD WARRANTY: Seller warrants that products of its own manufacture will be free from defects 

in workmanship and materials under normal use and service for the period specified in the product 

instruction manual.  Warranty for service parts will be ninety (90) days from date of factory shipment.  

Electric Motors, gasoline and diesel engines, electrical apparatus and all other accessories, components 

and parts not manufactured by Seller are warranted only to the extent of the original manufacturer’s 

warranty.
Notice of the alleged defect must be given to the Seller, in writing with all identifying details including 

serial number, type of equipment and date of purchase within thirty (30) days of the discovery of the same 

during the warranty period. 
Seller’s sole obligation on this warranty shall be, at its option, to repair or replace or refund the purchase 

price of any product or part thereof which proves to be defective.   If requested by Seller, such product or 

part thereof must be promptly returned to seller, freight prepaid, for inspection.
Seller warrants repaired or replaced parts of its own manufacture against defects in materials and 

workmanship under normal use and service for ninety (90) days or for the remainder of the warranty on the 

product being repaired.
This warranty shall not apply and Seller shall not be responsible or liable for:

(a)  Consequential, collateral or special losses or damages;
(b)  Equipment conditions caused by fair wear and tear, abnormal conditions of use, accident, neglect 

or misuse of equipment, improper storage or damage resulting during shipping;

(c)  Deviation from operating instructions, specifications or other special terms of sale;
(d)  Labor charges, loss or damage resulting from improper operation, maintenance or repairs made by 

person(s) other than Seller or Seller’s authorized service station.

In no event shall Seller be liable for any claims whether arising from breach of contract or warranty or 

claims of negligence or negligent manufacture in excess of the purchase price.
THIS WARRANTY IS THE SOLE WARRANTY OF SELLERS AND ANY OTHER WARRANTIES, 

WHETHER EXPRESS OR IMPLIED IN LAW OR IMPLIED IN FACT, INCLUDING ANY WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR PARTICULAR USE ARE HEREBY SPECIFICALLY EXCLUDED.
LIABILITY LIMITATIONS: Under no circumstances shall the Seller have any liability for liquidated damages 

or for collateral, consequential or special damages or for loss of profits, or for actual losses or for loss of 

production or progress of construction, whether resulting from delays in delivery or performance, breach of 

warranty, negligent manufacture or otherwise.
ENVIROMENTAL AND OSHA REQUIREMENTS: At the time of shipment of the equipment from the factory, 

Quincy Compressor / Ortman Fluid Power will comply with the various Federal, State and local laws and 

regulations concerning occupational health and safety and pollution.  However, in the installation and 

operation of the equipment and other matters over which the seller has no control, the Seller assumes no 

responsibility for compliance with those laws and regulations, whether by the way of indemnity, warranty or 

otherwise.

30 

Quincy Compressor-QPHT

Back to TOC

Содержание Quincy Compressor QPHT 100

Страница 1: ...s important safety information and should be made available to all personnel who operate and or maintain this product Carefully read this manual before attempting to operate or perform maintenance on this equipment Manual No 65505 2A April 2008 Edition ...

Страница 2: ......

Страница 3: ...eshooting 14 QPHT 25 Parts Lists 15 QPHT 50 Parts Lists 16 QPHT 75 Parts Lists 17 QPHT 100 Parts Lists 18 QPHT 125 Parts Lists 19 QPHT 25 Dimensional 20 QPHT 50 Dimensional 21 QPHT 75 100 125 Dimensional 22 QPHT 25 Wiring Diagram 23 QPHT 50 Wiring Diagram 24 QPHT 75 115V Wiring Diagram 25 QPHT 75 230V Wiring Diagram 26 QPHT 100 125 115V Wiring Diagram 27 QPHT 100 125 230V Wiring Diagram 28 Quincy ...

Страница 4: ......

Страница 5: ...n this manual and posted on the unit Keep this manual near the unit and in a safe place Replace this manual if it becomes torn or dirty and cannot be properly used Please read the Operating Instructions section of this manual before attempting to operate the unit Please read the Maintenance Adjustments and Troubleshooting sections of this manual before beginning any maintenance or service work on ...

Страница 6: ...hemical spills oil solvents and wet floors All of these can damage a hose USE SUITABLE PARTS ACCESSORIES Do not use air pressurized accessories or parts in the air system not suitable for the maximum air pressure used Be sure maximum pressure specified by the accessory manufacturer is well above the working pressure of your compressor RELEASE AIR PRESSURE SLOWLY Fast moving air will stir up dust a...

Страница 7: ...he manufacturer of the material being sprayed Spray in an open area away from flames and electrical equipment Fumes are dangerous Spray in a well ventilated area to keep fumes from collecting and causing health and fire hazards Do not spray in vicinity of open flames or other areas where a spark can cause ignition Do not smoke when spraying paint insecticides or other flammable substances Use a re...

Страница 8: ...ad a pipe nipple on the air outlet connection Install the filter to the pipe nipple with arrow on filter pointing away from air dryer unit Use pipe sealer on both ends of the nipple to facilitate sealing without undue torque pressure Notice Optional coalescing oil filter must be installed with direction arrow facing AWAY from the air dryer system unit If the oil filter is installed backwards disch...

Страница 9: ...d national electrical codes The air dryer system has been tested and shipped with a full charge of oil and refrigerant Inspect the suction pressure gauge located on the front of the unit refer to Figures 1 3 While the unit is idle not operating the refrigerant suction pressure should be within the range of 90 to 130 PSIG If the suction pressure gauge reads 0 PSIG or near 0 PSIG contact Quincy or y...

Страница 10: ...ER YEAR HOT GAS BYPASS VALVE DRAIN SOLENOID VALVE REFRIGERANT SUCTION PRESSURE GAUGE ON OFF SWITCH PUSH TO TEST SWITCH CYCLE TIME DRAIN TIME OPTIONAL AMBIENT FILTER AIR INTAKE ELECTRIC POWER CONNECTION AIR INLET AIR OUTLET OPTIONAL OIL FILTER SIGHT GLASS MOISTURE DRAIN TUBE Figure 1 Model QPHT 25 Quincy Compressor QPHT Back to TOC ...

Страница 11: ...MOISTURE SEPARATOR DRAIN SOLENOID VALVE Y STRAINER CLEANOUT PORT TURN VALVE OFF BEFORE REMOVING CLEAN 4 TIMES PER YEAR FAN MOTOR REFRIGERATION COMPRESSOR HOT GAS BYPASS VALVE AIR FLOW ON OFF SWITCH PUSH TO TEST SWITCH CYCLE TIME DRAIN TIME AIR FLOW REFRIGERANT SUCTION PRESSURE GAUGE Figure 2 Model QPHT 50 Quincy Compressor QPHT Back to TOC ...

Страница 12: ...E DRAIN TIME FAN MOTORS REFRIGERATION COMPRESSOR HOT GAS BYPASS VALVE Y STRAINER CLEANOUT PORT TURN VALVE OFF BEFORE REMOVING CLEAN 4 TIMES PER YEAR DRAIN SOLENOID VALVE DRAIN CONNECTION ELECTRIC POWER CONNECTION OPTIONAL OIL FILTER AIR OUTLET AIR INLET MOISTURE SEPARATOR Figure 3 Model QPHT 75 100 125 Quincy Compressor QPHT Back to TOC ...

Страница 13: ...rocedure should be repeated 3 or 4 times in every 8 hour period of operation The moisture drain valve operates automatically and is controlled with the CYCLE TIME and DRAIN TIME knobs Initially both knobs should be turned counterclockwise to the seven o clock position When using the unit after shipment check both knobs and turn to the seven o clock position if they have been moved The controls are...

Страница 14: ...ight High temperature light Refrigerant suction pressure gauge Drain test button Drain timer adjustment controls 2 Model QPHT 50 Unit Dimensions Length 28 Width 18 Height 30 Flow 50 SCFM Inlet Pressure 175 PSIG 200 PSIG Maximum Ambient Temperature Minimum 55 F 13 C Maximum 100 F 38 C Inlet Temperature 180 F 82 C Maximum Dew Pt Temperature 50 F 2 10 C 1 Refrigerant H P 1 3 Heat Exchanger Material C...

Страница 15: ...nts The ON OFF switch holds a HIGH TEMP light which will turn on if the unit s compressor system malfunctions If the red HIGH TEMP light on this switch is illuminated turn off and unplug the unit for 15 minutes and restart If the light remains on after restarting or it continues to turn on afterwards contact Quincy or your distributor Periodic maintenance The following procedures should be perform...

Страница 16: ...air dryer system Warning Depressurize air dryer system before removing coalescing oil filter bowl Failure to do so will cause the filter to blow off its fitting and cause bodily injury and property damage a Remove the filter bowl the bottom half of the assembly by turning the bowl counterclockwise Clean the bowl and the drain stem with water and a mild soap solution Notice When reinstalling the fi...

Страница 17: ...any sediment or foreign material from the lines Reinstall the moisture separator bowl the lower filter bracket the particle strainer assembly and the two drain hoses If the separator still will not drain contact Quincy or your distributor to order a new separator assembly Condenser coil cleaning Remove ambient filter if equipped Remove either the right or left side panel screws and panel Using com...

Страница 18: ... in the air systems Adjust hot gas bypass valve see Page 12 Low on refrigerant Call for service To confirm freeze up shut off the unit for 15 minutes Air pressure should come back to line pressure Continuous air flow through the moisture drain line Foreign materials lodged on the valve seat Press the PUSH TO TEST switch several times Disconnect the drain lines to the solenoid valve and blow compre...

Страница 19: ... Strainer Screen QFT 003845 1 Ambient Filter Optional QRF 000811 2 Coalescing Filter Element Optional CSNE00030 1 230V 1PH 60Hz PART DESCRIPTION PART NO QTY Refrigerant Condensing unit 25 HP R 134A QRF 001226 1 Fan Motor QRF 001277 1 Fan Blade QRF 000538 1 Receiver QRF 003224 1 Capillary Tube Assembly QRF 001182 1 Hot Gas Bypass Valve QVA 000579 1 Power On Off Switch QRF 001983 1 Suction Pressure ...

Страница 20: ...trainer Screen QFT 003845 1 Ambient Filter Optional QRF 002641 2 Coalescing Filter Element Optional CSNE00060 1 230V 1PH 60Hz PART DESCRIPTION PART NO QTY Refrigerant Compressor 0 33 HP R 134a 1624 5007 31 1 Fan Motor QRF 000795 1 Fan Blade QRF 000774 1 Receiver QRF 003224 1 Expansion Valve QVA 001784 1 Hot Gas Bypass Valve QVA 000579 1 Power On Off Switch QRF 001983 1 Suction Pressure Gauge QGM 0...

Страница 21: ...Strainer Screen QFT 003845 1 Ambient Filter Optional QRF 002641 2 Coalescing Filter Element Optional CSNE00060 1 230V 1PH 60Hz PART DESCRIPTION PART NO QTY Refrigerant Compressor 0 5 HP R 134A QRF 003110 1 Fan Motor QRF 000795 1 Fan Blade QRF 000774 1 Receiver QRF 003224 1 Expansion Valve QVA 001783 1 Hot Gas Bypass Valve QVA 000579 1 Fan Cycling Switch QRF 002079 1 Power On Off Switch QRF 001983 ...

Страница 22: ... Strainer Screen QFT 003845 1 Ambient Filter Optional QRF 002641 2 Coalescing Filter Element Optional CSNE00125 1 230V 1PH 60Hz PART DESCRIPTION PART NO QTY Refrigerant Compressor 0 5 HP R 134A QRF 003111 1 Fan Motor QRF 000795 1 Fan Blade QRF 000774 1 Receiver QRF 003224 1 Expansion Valve QVA 001783 1 Hot Gas Bypass Valve QVA 000579 1 Fan Cycling Switch QRF 002079 1 Power On Off Switch QRF 001983...

Страница 23: ... Strainer Screen QFT 003845 1 Ambient Filter Optional QRF 002641 2 Coalescing Filter Element Optional CSNE00125 1 230V 1PH 60Hz PART DESCRIPTION PART NO QTY Refrigerant Compressor 0 5 HP R 134A QRF 003111 1 Fan Motor QRF 000795 1 Fan Blade QRF 000774 1 Receiver QRF 003224 1 Expansion Valve QVA 001783 1 Hot Gas Bypass Valve QVA 000579 1 Fan Cycling Switch QRF 002079 1 Power On Off Switch QRF 001983...

Страница 24: ...High Temperature Refrigerated Air Dryers QPHT 25 Dimensional 20 Quincy Compressor QPHT Back to TOC ...

Страница 25: ...High Temperature Refrigerated Air Dryers QPHT 50 Dimensional Quincy Compressor QPHT 21 Back to TOC ...

Страница 26: ...High Temperature Refrigerated Air Dryers QPHT 75 100 125 Dimensional 22 Quincy Compressor QPHT Back to TOC ...

Страница 27: ...High Temperature Refrigerated Air Dryers QPHT 25 Wiring Diagram Quincy Compressor QPHT 23 Back to TOC ...

Страница 28: ...High Temperature Refrigerated Air Dryers QPHT 50 Wiring Diagram 24 Quincy Compressor QPHT Back to TOC ...

Страница 29: ...High Temperature Refrigerated Air Dryers QPHT 75 115V Wiring Diagram Quincy Compressor QPHT 25 Back to TOC ...

Страница 30: ...High Temperature Refrigerated Air Dryers QPHT 75 230V Wiring Diagram 26 Quincy Compressor QPHT Back to TOC ...

Страница 31: ...High Temperature Refrigerated Air Dryers QPHT 100 125 115V Wiring Diagram Quincy Compressor QPHT 27 Back to TOC ...

Страница 32: ...High Temperature Refrigerated Air Dryers QPHT 100 125 230V Wiring Diagram 28 Quincy Compressor QPHT Back to TOC ...

Страница 33: ... and storage charges may be applied at the discretion of Seller Accounts past due shall bare interest at the highest rate lawful to contract for but if there is no limit set by law such interest shall be eighteen percent 18 Buyer shall pay all cost and expenses including reasonable attorney s fees incurred in collecting the same and no claim except claims within Seller s warranty of material or wo...

Страница 34: ...o seller freight prepaid for inspection Seller warrants repaired or replaced parts of its own manufacture against defects in materials and workmanship under normal use and service for ninety 90 days or for the remainder of the warranty on the product being repaired This warranty shall not apply and Seller shall not be responsible or liable for a Consequential collateral or special losses or damage...

Страница 35: ...________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ___________________________________________________________________...

Страница 36: ...________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ___________________________________________________________________...

Страница 37: ......

Страница 38: ... 2008 Quincy Compressor an EnPro Industries company All Rights Reserved Litho in U S A Quincy Compressor Products 217 222 7700 E mail info quincycompressor com Website www quincycompressor com ...

Отзывы: