USER MANUAL
V0.904
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax +49.89.67
34
689-50
[email protected]
www.enocean.com
Subject to modifications
STM110C User Manual V0.904
February 18, 2008 2:00 PM
Page 25/40
STM110C
INF_SYS_SW_VERSION
Description:
This telegram contains the SW version of the module.
Command encoding
Bit 7
Bit 0
0xA5
0x5A
0x8B
0x8C
SW Version Byte3
SW Version Byte2
SW Version Byte1
SW Version Byte0
0x00
0x00
0x00
0x00
0x00
ChkSum
SW Version Byte3..0: Software version, MSB first
INF_SYS_AD_THRES
Description:
This telegram contains the current threshold values at the analog inputs which lead to a
radio transmission.
Command encoding
Bit 7
Bit 0
0xA5
0x5A
0x8B
0x01
AD_2_MIN_VARIATION
AD_1_MIN_VARIATION
AD_0_MIN_VARIATION
0x00
0x00
0x00
0x00
0x00
0x00
ChkSum
AD_2_MIN_VARIATION: Treshold at AD_2: 0..0xFF LSB
AD_1_MIN_VARIATION: Treshold at AD_1: 0..0xFF LSB
AD_0_MIN_VARIATION: Treshold at AD_0: 0..0xFF LSB