6.6
Public data
Public data can be read by any NFC-capable device supporting the ISO/IEC 14443 Part 2
and 3 standards. No specific security measures are used to restrict read access to this data.
The following items are located in the public data area:
Product Name
This is always “
PTM 215B
” to designate the PTM 215B module used within the EDRPB
or ESRPB rocker switch
Product ID
This is an 8 byte field which is by default set to
0x0000000000000000
.
Product ID and Manufacturer ID can be configured by the customer as required to
uniquely identify his products, see chapter 6.7.4
Manufacturer ID
This is an 2 byte field used to identify the manufacturer of a BLE product, see chap-
ter 4.6. This field is by default set to
0x03DA (EnOcean GmbH)
.
Product ID and Manufacturer ID can be configured by the customer as required to
identify his products, see chapter 6.7.4
Static Source Address
This is a 4 byte field used to identify the static source address used by ExRPB, see
chapter 4.4.1. Each ExRPB is pre-programmed with an individual static source ad-
dress.
The Static Source Address can be configured by the customer as required to identify
his product, see chapter 6.7.2
Hardware Revision, Software Revision and NFC Revision
These fields identify the device revision
Telegram sequence counter
This is a 4 byte field which is initialized to 0 during manufacturing and incremented
for each transmitted telegram. Receivers shall never accept telegrams containing
sequence counter values equal or less than previously received values to avoid re-
play attacks.
Changing the Static Source Address, Manufacturer ID and Product ID fields is only possible
via protected data access as described below to prevent unauthorized modification.
For security reasons, the telegram sequence counter cannot be written or reset by any
mechanism.