background image

ennoLogic Thermal Imaging Camera eT450C - User Manual 

 

11 

 

How to Use Your Thermal Imaging Camera 

Operating Instructions 

Powering the Camera On and Off 

Press  and  hold  the  “   /  MENU”  button 

for  more  than  3 

seconds

 to turn the Thermal Imaging Camera on or off. This 

relatively long press time is designed to prevent accidental 
powering  on  or  off  of  the  camera.  This  is  particularly 
important if the user has chosen to disable auto shutdown, 
in which case an accidental powering on of the camera could 
result in a drained battery. 
 

Please note that there will be no indication on the screen 
during the long-press of the power button. Hold the power 
button  for  at  least  3  seconds  or  until  the  boot  image 
appears  on  the  screen.  Conversely,  when  powering  the 
camera  down,  long-press  the  power  button  for  at  least  3 
seconds  or  until  the  power  off  counter  appears  on  the 
screen. 

LCD Display 

After turning on the power you will see the boot screen and 
progress bar for a few seconds. Then the camera will be live. 
 

Note: 

If the camera has been moved between extreme hot or cold 
environments you  may need to allow the camera to adjust 

Содержание eT450C

Страница 1: ...Thermal Imaging Camera eT450C User Manual...

Страница 2: ...Version 1 1 Revised 3 21 2020 2020 ennoLogic All rights reserved https ennologic com...

Страница 3: ...nstrument Description 7 Main User Elements 7 LCD Display 9 Keypad 10 How to Use Your Thermal Imaging Camera 11 Operating Instructions 11 Menu Description 14 Image Alignment 14 Images 14 Color Palette...

Страница 4: ...ng hottest All objects emit some level of infrared radiation This camera measures temperature by sensing infrared radiation which is outside the visible light spectrum and making it visible as an imag...

Страница 5: ...rcuits and fires Do not attempt to remove the built in Lithium battery Tampering with the battery may result in dangerous leakage or explosion Unplug the power adapter when it s not in use or when the...

Страница 6: ...o avoid the potential risks of short circuit and fire Use only the provided USB power adapter to charge the camera s battery Use of other power supply accessories may cause overheating electric shock...

Страница 7: ...ment and periodically charge the battery This will extend the life of the built in Lithium Ion battery Important Note Limited Liability Cascadia Innovations is the exclusive distributor of all ennoLog...

Страница 8: ...ed performance allows for instant detection and diagnosis of problems in operating machinery with no need to power down or interrupt operation Application examples include Search and resuce such as fi...

Страница 9: ...camera provides an instant thermal snapshot of the entire field of view This saves time by making it easy to identify potential problems at a glance Use the center point cursor to quickly pinpoint any...

Страница 10: ...ther tasks Examples of these features in addition to those listed above include adjustable emissivity for increased measurement accuracy five user selectable color palettes adjustable opacity of visib...

Страница 11: ...ennoLogic Thermal Imaging Camera eT450C User Manual 8 Figure 2...

Страница 12: ...o bottom Center point temperature cursor this white cursor is always located in the center of the screen and its corresponding temperature is displayed in the top left corner Highest temperature curso...

Страница 13: ...ging Camera eT450C User Manual 10 Lowest temperature cursor this green cursor always appears at the coldest spot of the displayed thermal image Its corresponding temperature is displayed at the bottom...

Страница 14: ...tal powering on of the camera could result in a drained battery Please note that there will be no indication on the screen during the long press of the power button Hold the power button for at least...

Страница 15: ...sity on top of the visible image This makes it easier to intrepet the thermal image provides more detailed information and improves analysis of heat distribution To adjust the opacity press the or but...

Страница 16: ...a computer via USB Open the protective cover for the Micro USB port on the top of the camera see Figure 2 Then use the included USB cable to connect the camera to your computer Your computer will init...

Страница 17: ...allows you to compensate for the parallax between the visible and infrared cameras Press the MENU button to enter the main menu and select Image alignment Press the SELECT ENTER button to enter the i...

Страница 18: ...NU button to exit this mode Delete Images While viewing an image press the button The screen will display the prompt Delete photo with the preselected answer Yes If you want to delete the image press...

Страница 19: ...for specific applications and should be chosen as needed Choosing the right color palette will enhance the display of details of the target object Color palettes such as rainbow spectrum iron oxide re...

Страница 20: ...f a material is the ability of its surface to emit thermal radiation More accurately it is the ratio of the energy radiated from a material s surface to that radiated from a perfect emitter black body...

Страница 21: ...ty of the object Emissivity of a material surface is difficult to estimate since it depends on its texture color and temperature A good default setting is 0 95 The emissivity of this camera can be adj...

Страница 22: ...ct the digit to be changed press the buttons to change the value After the desired emissivity value has been entered press SELECT ENTER to confirm Then press the MENU button to apply the new value and...

Страница 23: ...ble white 0 95 Mortar 0 87 Paper white 0 68 Plastic 0 84 0 95 Quartz Glass 0 93 Rubber black 0 95 Sand 0 90 Skin human 0 98 Snow 0 80 Soil 0 92 0 95 Steel oxidized 0 75 Steel polished 0 07 Tape electr...

Страница 24: ...low gives an overview of the available settings and their possible values Settings Auto shutdown Intensity Language Unit Set time Spot WiFi Auto shutdown 5min 20min none Intensity Low Medium High Lang...

Страница 25: ...press the button to enter the intensity setting list The intensity display brightness can be set to Low Medium or High Language After selecting Language press the button to enter the languages list Av...

Страница 26: ...uttons to select Year Month Day Hour Minute or Second Press SELECT ENTER to enter the edit mode Press the buttons to select the digit to be changed press the buttons to change the value After the desi...

Страница 27: ...t Temperature Cursor After selecting Spot press the button to make your selection to enable or disable the Highest Lowest Temperature cursors Press to select Off or On Press SELECT ENTER to confirm th...

Страница 28: ...al xxxx xxxx are the last four digits of the MAC Connect to the camera with your computer or mobile device Then open a web browser and access the camera through the IP address 192 168 230 1 type http...

Страница 29: ...ennoLogic Thermal Imaging Camera eT450C User Manual 26...

Страница 30: ...Stream to return to the live stream of the camera Please note that any operation in your web browser will not reset the auto shutdown clock of the camera only a button press on the camera will do tha...

Страница 31: ...included USB power adapter and cable through the Micro USB port in the top of the camera After the battery has been fully recharged disconnect the USB cable from the charger and unplug the USB charge...

Страница 32: ...reen use only professional optical cleaning cloths Lens Maintenance To prevent damage to the infrared lens The infrared lens has a sensitive anti reflective coating Clean with caution and very little...

Страница 33: ...0 07 Frame rate of thermal images 9 frames per second Focus mode Fixed Wavelength coverage 8 14 m Emissivity Adjustable 0 01 to 1 00 Color palette Rainbow iron oxide red cool color white heat black he...

Страница 34: ...age temp unit time format date time high low temperature cursors Wifi Language English Chinese Italian German Auto Shutdown Selectable 5 minutes 20 minutes No auto shutdown disabled Operating temperat...

Страница 35: ...ennoLogic Thermal Imaging Camera eT450C User Manual 32...

Страница 36: ...ennoLogic com PO Box 25207 Eugene OR 97402...