6.0 Replacement Part Numbers 

ENMET

 replacement part numbers: 

Description Part 

Number 

For 

EX-5175-EC 

p/n  

Sensor: Oxygen 
 Carbon 

Monoxide 

 Hydrogen 

Sulfide 

 Ammonia 
 

Sulfur Dioxide  

67027-1100 
67027-1200 
67027-0200 
67027-2400 
67027-0500 

Consult 

ENMET

 Distributor or 

ENMET

 Corp for additional sensors 

Regulator Assembly, for 34/58/103

 cylinders 

02506-002 

Magnet 50030-001 

Calibration/Sampling Adapter 

03700-034 

Regulator Assembly, for 17/34

 cylinders 

02506-004 

Calibration Gas, Consult 

ENMET

 Distributor or 

ENMET

 Corp. 

 

 

 

7.0 WARRANTY 

ENMET

 warrants new instruments to be free from defects in workmanship and material under normal use for a period 

of one year from date of shipment from 

ENMET

.  The warranty covers both parts and labor excluding instrument 

calibration and expendable parts such as calibration gas, filters, batteries, etc...  Equipment believed to be defective 
should be returned to 

ENMET

 within the warranty period (transportation prepaid) for inspection.  If the evaluation by 

ENMET

 confirms that the product is defective, it will be repaired or replaced at no charge, within the stated 

limitations, and returned prepaid to any location in the United States by the most economical means, e.g. Surface 
UPS/FedEx Ground.  If an expedient means of transportation is requested during the warranty period, the customer is 
responsible for the difference between the most economical means and the expedient mode. 

ENMET

 shall not be 

liable for any loss or damage caused by the improper use of the product.  The purchaser indemnifies and saves 
harmless the company with respect to any loss or damages that may arise through the use by the purchaser or others of 
this equipment. 

This warranty is expressly given in lieu of all other warranties, either expressed or implied, including that of 
merchantability, and all other obligations or liabilities of 

ENMET

 which may arise in connection with this equipment.  

ENMET

 neither assumes nor authorizes any representative or other person to assume for it any obligation or liability 

other than that which is set forth herein.  

NOTE:  When returning an instrument to the factory for service: 

 

Be sure to include paperwork. 

 

A purchase order, return address and telephone number will assist in the expedient repair and return of your unit. 

 

Include any specific instructions. 

 

For warranty service, include date of purchase 

 

If you require an estimate, please contact 

ENMET 

Corporation. 

There are Return for Repair Instructions and Form on the last pages of this manual.  This Form can be copied or used 
as needed. 

 

Manual Part Number 
80003-099 

January 2008 
MCN-418, 04/16/09 
MCN-447, 05/24/11 
MCN-459, 12/13/11 
MCN-13-008, 11/06/13 

 

Содержание EX-5175-EC

Страница 1: ...ENMET Corporation PO Box 979 Ann Arbor MI 48106 0979 www enmet com Manual Part Number 80003 099 MCN 13 008 11 06 13 EX 5175 EC Sensor Transmitter Manual...

Страница 2: ......

Страница 3: ...acement 11 6 0 REPLACEMENT PART NUMBERS 12 7 0 WARRANTY 12 List of Figures and Tables Figure 1 EX 5175 EC Features 2 Figure 2 EX 5175 EC Mounting Dimensions 3 Figure 3 Terminal Positions EX 5175 EC Se...

Страница 4: ......

Страница 5: ...and the contents After the inspection and after you have received written acknowledgment of the damage from the carrier contact ENMET Customer Service for return authorization and further instruction...

Страница 6: ...ment maintenance functions The switch locations are indicated by MENU and SELECT A magnetic field pulse is applied by momentarily putting the end of the magnet in proximity to the switch and then remo...

Страница 7: ...oosing locations of sensor transmitters Also take into consideration environmental factors when deciding on S T location Avoid locations where the S T may be damaged by liquid immersion excessive heat...

Страница 8: ...ct the wires from the controller power supply to the supplied J4 plug then attach to J4 terminal See Figure 3 for locations J4 PLUG TERMINAL TO CONTROLLER WIRING Position Function 1 24 VDC power 2 GND...

Страница 9: ...hen power is supplied to the EX 5175 EC the S T will display the following sequence of information NOTE Software revision may cause variations of display output Example of Display Function The instrum...

Страница 10: ...on below Display Measurement of the target gas Tap the magnet over the MENU button Display indicates Alarm 1 Set point Tap the magnet over the MENU button Display indicates Alarm 2 Set point Tap the m...

Страница 11: ...of target gas Hold the magnet over MENU switch for 2 5 seconds to enter the Maintenance Menu The Power Fault LED will flash Green Red to indicate the EX 5175 EC is in Maintenance Mode To exit the main...

Страница 12: ...C transmitters Calibration equipment is available from ENMET Corporation to calibrate the EX 5175 EC sensor transmitters A calibration adapter will have a fitting for the gas cylinder on one side and...

Страница 13: ...Figure 4 3 Open the valve to apply the calibration gas to the sensor wait approximately 120 seconds 2 minutes 4 Tap the SELECT switch to perform a Span procedure The display will alternate between th...

Страница 14: ...anges digit indicated by underscore cursor The SELECT switch locks underscored digit and moves to next digit See Section 5 2 2 SELECT mA Span MENU SELECT 100 To change mA Span set point Tap the MENU s...

Страница 15: ...d Assembly into the sensor housing cover Reassemble the sensor housing Turn On the sensor transmitter After the new sensor has been installed it is suggested to allow the sensor to stabilize for 24 ho...

Страница 16: ...edEx Ground If an expedient means of transportation is requested during the warranty period the customer is responsible for the difference between the most economical means and the expedient mode ENME...

Страница 17: ...processing delays ENMET charges a one hour minimum billing for all approved repairs with additional time billed to the closest tenth of an hour All instruments sent to ENMET are subject to a minimum...

Страница 18: ......

Страница 19: ..._____________ Payment Terms COD Check one VISA MasterCard______________________ ________ ________ Card number Expiration Card Code American Express______________________ ________ ________ Card number...

Страница 20: ......

Отзывы: