AirGuard
TM
13
www.bullard.com
Warning! Maximum Supply inlet pressure cannot exceed 150psi
Review the personal protective equipment instructions to be used with AirGuard. You need to know the pressure
setting required for the correct flow.
Open the enclosure and adjust the delivery pressure by turning the regulator adjustment to the desired pressure
to deliver required SCFM as per the NIOSH approved respirator being used. Clockwise increases the pressure value.
Regulator
Adjustment
Knob