England's Stove Works 30-NCG Скачать руководство пользователя страница 10

 

10 

8” 

          

Pre-Manufactured Flue System

: In the past few years pre-manufactured flue systems have 

become very popular, because this type system is easily installed and, when done correctly, is very 
safe. There are many pre-manufactured flue systems on the market, and when making your choice it 
should be U.L., (U.L.C. if Canada), B.O.C.A. or I.C.B.O. approved. Any of these systems are 
constructed of the proper materials and meet the proper safety standards. Your local dealer normally 
handles an approved brand of flue pipe. There are two very popular methods for installation of this 
type system. 
 

     The 

first

, most popular and least expensive is through the ceiling and out the roof. This is the 

most direct route and creates a good draw because it requires less pipe. It is less expensive because 
insulated pipe is needed only from the ceiling to the roof and above -- single wall 24 gauge or thicker 
pipe is used from the unit to the ceiling if you maintain eighteen inches (18.0”) of clearance from all 
combustible material.  

 
     The 

second

 method for installing a pre-manufactured system is to exit through the wall and run 

the system vertically up the outside of the structure. This method is more expensive because more 
insulated pipe is required -- you must use insulated pipe through the wall and up the outside of the 
structure. In either installation, proper clearances to combustibles should be maintained. Your flue 
pipe manufacturer furnishes a wall thimble or ceiling support box and, when installed properly, the 
correct clearances are achieved. If you are unable to install this type system your local dealer may be 
able to recommend a qualified contractor for this installation. It is the customer’s responsibility to 
ensure that his system is installed properly and is in good operating condition.  

The manufacturer will not be responsible for an accident caused by a unit connected to a faulty 

flue system.  

 

 

FLOOR AND WALL PROTECTION 

 

1.  Floor  Protection 

     You will not need any floor protection if your 
floor is constructed of a non-combustible material 
such as brick or concrete. If your floor is 
constructed with a combustible material such as 
hardwood, carpet or linoleum, you must place 
protection between the stove and the combustible 
material.  
     There  are  many  floor  and  wall  board 
manufacturers, and you should be very cautious 
in choosing the proper protection. The type board 
you choose should be U.L. rated and listed (ULC 
if Canada).  After examining the area you plan to place your stove and determining it requires a 
board, the next step is to select the proper size. The stove you choose will determine the size 
board that is required. The approved protector board should be large enough to provide a 
minimum of eight inches (8”) behind the unit, eight inches (8”) on both sides and sixteen inches 
(16”) in the front where the door is located. *NOTE: For Canada, 450 mm is required in front and 
200 mm on the sides and back. The protection must have an R-value of 1.5 (English units) or 
equivalent (See “Installation on a Combustible Floor”).  This stove requires a minimum 39.0” x 
52.5” floor protection. 

Installation on a Concrete Floor 

     An appliance mounted on a concrete floor does not require floor protection. 
Carpeting and any other combustible material must not cover the Floor Protector. 
     If a combustible surface is applied to the concrete floor, a clearance must be maintained 
equivalent to the area reserved for the floor protector. 

 

Floor 

Protector 

 
-Minimum R 
value of 1.5 
 
-Minimum size: 
39”W 

x  

52.5”D 

*See NOTE 
for Canada 

Содержание 30-NCG

Страница 1: ...INSTALLATION OPERATION MANUAL Manufactured By England s Stove Works Inc PO Box 206 Monroe VA 24574 Rev 12 2016 Wood Stove MODELS 30 NC 50 SNC30 50 TNC30 SAVE THESE INSTRUCTIONS ...

Страница 2: ...oor Gasket 18 Fiber Board 18 Burner Tubes 18 Creosote 20 Ash Disposal 20 Questions Hints and Tips 21 Parts and Options Parts Options List 23 Legs Pedestal Installation 24 Warranty Sample Tag 25 Warranty Details 26 Warranty Registration Form 27 Important Information EPA and Safety Info 29 IMPORTANT NOTES CLEARANCES MAY ONLY BE REDUCED BY MEANS APPROVED BY THE REGULATORY AUTHORITY HAVING JURISDICTIO...

Страница 3: ... WIDE APPROVED WITH OUTSIDE AIR HOOK UP FOR THE PEDESTAL MODEL ONLY NOT FOR LEG MODELS DO NOT INSTALL IN A SLEEPING ROOM THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED CAUTION This unit must be installed in accordance with these instructions and must comply with local building and fire codes Failure to do so could result in a chimney or house fire Keep c...

Страница 4: ...information obtained on our web site and through our 800 number is always free of charge there will be a service charge incurred with any on site repairs or maintenance that we may arrange Wishing you years of efficient quality and comfy heating England s Stove Works Technical Support Department www HeatRedefined com 800 245 6489 This manual is available for free download on the manufacturer s web...

Страница 5: ...ombustible materials too close to the unit 12 Contact your local fire authority for information on how to handle a chimney fire Have a clearly understood plan to handle a chimney fire In the event of a chimney fire turn air control to a closed position and CALL THE FIRE DEPARTMENT 13 DO NOT tamper with the combustion air control beyond normal adjustment 14 Once the required draw is obtained operat...

Страница 6: ...s that exceed heater design specifications can result in permanent damage to the heater The recommended wood load is level with the top of the firebricks Overloading may prevent sufficient air entering the heater to properly fuel the fire Do not tamper with the combustion air control beyond the normal adjustment capacity Operate this heater only with the door closed DO NOT OVERFIRE If the heater o...

Страница 7: ...nished with the unit Masonry Flue In the event that you plan to install or have a system installed there are several approaches that you can take In the middle and late seventies masonry flue systems became very popular and today this type system is satisfactory If you are considering a masonry system you should consult with your local building officials for the proper procedures on this type chim...

Страница 8: ... Lined with clay tile or other liner C E A IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunction of a stove due to improper installation Do not use makeshift methods or material which may compromise the installation England s will not be liable for consequential or indirect damages to property or persons resulting from the use of this product Call...

Страница 9: ...9 INSTALLATION APPLICATIONS Cont d Illustration 1b In Canada the installation must conform to CAN CSA B365 when passing through combustible construction ...

Страница 10: ... this installation It is the customer s responsibility to ensure that his system is installed properly and is in good operating condition The manufacturer will not be responsible for an accident caused by a unit connected to a faulty flue system FLOOR AND WALL PROTECTION 1 Floor Protection You will not need any floor protection if your floor is constructed of a non combustible material such as bri...

Страница 11: ...tor of 0 84 The proposed alternate is 4 brick with a C factor of 1 25 over 1 8 mineral board with a k factor of 0 29 Step a Use formula above to convert specification to R value R 1 k x T 1 0 84 x 75 0 893 Step b Calculate R of proposed system 4 brick of C 1 25 therefore R brick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 4...

Страница 12: ...e Heat Shield with the existing holes in the Rear Heat Shield and fasten with the screws provided See Illustration 1 for clearances with and without side heat shields Rear Heat Shield Side Heat Shield Side Heat Shield Illustration 3 Side Heat Shield and Optional Blower Installation Install AC 30 Optional Blower on these 4 mounting holes See Optional Blower Instructions BRICK LAYOUT 1 Unmarked on d...

Страница 13: ... motor The fan speed should be run on Low when the unit is operating at lower burn settings and set to High for high burns When routing the power cord be sure that the cord does not come into contact with any hot surface OPTIONAL BLOWER MODEL AC 30 120 VOLTS 60Hz 0 75 AMPS 3000 RPM DANGER RISK OF ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT OPTIONAL BLOWER MOTOR OPERATING INSTRUCTIONS Thi...

Страница 14: ...double wall or shielded pipe INSTALLATION 1 Remove all parts from inside the stove body 2 Select the proper location for the stove These appliances must not be installed any closer than the minimum clearance to combustible materials shown in Illustration 1 The stove must be installed on a non combustible surface as shown in Illustration 1 and Illustration 2 3 If non combustible materials have been...

Страница 15: ...stove in a regular dwelling this connection is not necessary but is recommended in air tight homes A kit is available from England s Stove Works Inc designed for connecting this unit to outside combustion air Part No AC OAK3 REFER TO CHIMNEY AND CHIMNEY CONNECTOR MANUFACTURER S INSTRUCTIONS WARNING INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER 3 Ft min from Roof Penetration Min ove...

Страница 16: ...cated under the ash drawer Pulling out on the control opens it 2 Place a small amount of crumpled paper in the stove 3 Cover the paper with a generous amount of kindling in a teepee shape and a few small pieces of wood 4 Ignite this fuel and close the door most of the way leave it open slightly 5 Add larger pieces of wood as the fire progresses being careful not to overload Do not fill the firebox...

Страница 17: ...ce deposits on the glass GASKET REPLACEMENT After extensive use the sealing material which provides glass and door seal may need to be replaced if it does not sustain its resilience Inspect the glass and door seal periodically to ensure proper seal If the gaskets become frayed or worn replace immediately Contact your dealer or Customer Service at 800 245 6489 or www heatredefined com for approved ...

Страница 18: ...OF THE STAINLESS STEEL TUBES AND PUSHED ALL THE WAY TO THE BACK OF THE UNIT WITH NO GAPS BETWEEN IT AND THE BACK WALL Call 800 245 6489 if questions MAINTENANCE This unit is equipped with a ceramic Fiber Board ceiling baffle two pieces After extensive use the board should be removed and cleaned The following steps should be followed for cleaning or replacement 1 Ensure the appliance is not in oper...

Страница 19: ...19 Placement of Stainless Steel Burner Tubes for all 30 NC 50 SNC30 and 50 TNC30 stove models ...

Страница 20: ...ll hot fire is preferable to a large smoldering one that can deposit creosote within the system 5 Establish a routine for fuel wood burner and firing technique Check daily for creosote build up until experience shows you how often you need to clean to be safe Keep in mind that the hotter the fire the less creosote is deposited and weekly cleanings may be necessary in milder weather although monthl...

Страница 21: ... started to ignite and the smoke has reduced close the stove door fully Reduction of smoke is a good indication that the draft in the chimney has begun and good combustion is now possible Larger pieces of seasoned dry firewood can now be added when there is sufficient space in the firebox Adjust the air control setting to your desired setting NOTE The lower the air control setting the longer the b...

Страница 22: ... the home Increased amounts of insulation vinyl windows extra caulking in various places and door seals can all keep heat in but may also make a home too airtight If you are in doubt as to whether or not there is sufficient air in your home for your stove refrain from using those appliances known to consume air when possible or open a door or a window to allow some air to enter the home D Environm...

Страница 23: ...ASS DOOR SPRING HANDLE AC SHN NICKEL DOOR SPRING HANDLE AC SH4 BRASS AIR CONTROL SPRING HANDLE AC SH4N NICKEL AIR CONTROL SPRING HANDLE AC 03 BRASS ASH PAN KNOB AC 03BN NICKEL ASH PAN KNOB AC MCSP HI TEMPERATURE CHARCOAL PAINT AC MBSP HI TEMPERATURE BLACK PAINT OPTIONS AC 30 ROOM AIR BLOWER AC 30SHSB SIDE HEAT SHIELD SYSTEM BLACK AC 115 BRASS LIP TRIM AC 115BN NICKEL LIP TRIM CA 12G GOLD PLATED LE...

Страница 24: ...lot and match the hole on the leg with the hole in the slot Attach the legs one at a time using the supplied bolts and nuts Tighten securely To install pedestal 1 Place spacers provided between the slots on the unit and the pedestal base one spacer will fit on each side of the pedestal Match the four holes in the pedestal 2 on each side with the holes in the spacers and slots on the unit 2 Use the...

Страница 25: ...ate and Serial Number in the space beside this sample tag for future reference This sample tag also shows the safety info such as UL ULC testing standard etc for your local officials or anyone else who may need reference information USA Canada ...

Страница 26: ...urs because of an accident improper handling improper installation improper operation abuse or unauthorized repair made or attempted to be made The manufacturer is not liable for indirect incidental or consequential damages in connection with the product including any cost or expense providing substitute equipment or service during periods of malfunction or nonuse All liability for any consequenti...

Страница 27: ... Purchase Date _________________ Purchase Price ____________________ Serial Number _____________________ Mfg Date ______________________ How did you first hear about our product please check one ___ Word of Mouth ___ Burn Trailer Demonstration ___ Internet Other __________________________________________________ Where did you receive information about our product please check one ___ Rec d info vi...

Страница 28: ...28 ...

Страница 29: ...himney system pulls air through the stove This unit must be installed in accordance with the following detailed descriptions of venting techniques not installing the stove in accordance with the details listed here can result in poor stove performance property damage bodily injury or death Avoid make shift compromises when installing the venting system England s Stove Works is not responsible for ...

Страница 30: ...ust terminate 3 0 ft above the point where it s centerline passes through the roof AND the chimney must terminate 2 0 ft above part of the dwelling within a 10 ft radius of the chimney Operation and Maintenance Please refer to the Operation Operating Instructions and Maintenance including Ash Removal Disposal sections of your owner s manual and follow the guidelines listed therein for safety and f...

Страница 31: ...ks and can also split twist or otherwise change shape as it dries most wood is dried before being used Air drying or seasoning is the most common method used for cord wood In most parts of the United States the minimum moisture content that can be generally obtained in air drying is about 12 to 15 percent Most air dried material is usually closer to 20 percent moisture content when used To test yo...

Страница 32: ...w these guidelines for safe operation Keep all flammable household items drapes furniture newspapers and books far away from the appliance Start fires only with newspaper dry kindling and all natural or organic fire starters Never start a fire with gasoline kerosene or charcoal starter Do not burn wet or green unseasoned logs Do not use logs made from wax and sawdust in your wood stove they are ma...

Страница 33: ...alarms CAUTION This unit is meant to operate only with door closed Smoke spillage and an inefficient lazy burn will result from attempting to operate the stove with the door open Additionally using prohibited fuels can create an unsafe situation and can also generate excess carbon monoxide Carbon monoxide is an odorless colorless gas which can be deadly The use of a carbon monoxide detector is str...

Страница 34: ......

Страница 35: ...L ON DORT L INTÉGRITÉ STRUCTURALE DU SOL DES MURS ET DU PLAFOND TOIT DE LA MAISON MOBILE DOIT OBLIGATOIREMENT ÊTRE MAINTENUE Cet appareil doit obligatoirement être installé conformément aux présentes instructions et doit obligatoirement respecter les codes locaux du bâtiment et de prévention des incendies Le non respect de ces instructions risque d entraîner un feu de cheminée ou dans la maison Te...

Страница 36: ... d aider nos clients à rester prêts à chauffer tout particulièrement quand les tarifs de l huile et de l électricité continuent d augmenter N hésitez pas à consulter l importante section d aide sur notre site Web et à appeler notre service clientèle au 800 245 6489 si vous avez besoin d aide avec votre poêle Nous pouvons presque toujours vous aider à effectuer n importe quelle réparation régler un...

Страница 37: ...act avec le service d incendie local pour tous renseignements sur la manière de traiter un feu de cheminée Ayez un plan clairement compris pour traiter un feu de cheminée En cas de feu de cheminée fermez la commande de tirage et APPELEZ LES POMPIERS 13 NE MANIPULEZ PAS la commande de tirage au delà des réglages normaux 14 Une fois le tirage requis obtenu ne faites fonctionner le poêle qu avec les ...

Страница 38: ...it de fumée une température suffisante pour permettre un tirage adéquat ce qui causera retour de fumée mauvaise combustion ou les deux En cas d apparition de ce genre de problème appelez un expert local en cheminées Quand la porte est fermée le taux de combustion dépend de la quantité d air qui pénètre dans l appareil par le régulateur d air Avec l expérience vous pourrez régler le régler en fonct...

Страница 39: ... de fumée ni tuyaux ne sont fournis avec l appareil Conduit de fumée maçonné Au cas où vous prévoiriez d installer un circuit ou d en faire installer un vous avez plusieurs solutions Au milieu et à la fin des années soixante dix les conduits de fumée maçonnés étaient très populaires et aujourd hui ce type de circuit reste satisfaisant Si vous envisagez un circuit maçonné consultez les responsables...

Страница 40: ...le simple Gainée de carreaux de terre ou autre gaine C E A MAUVAISE INSTALLATION Le fabricant ne sera pas tenu responsable des dommages causés par un dysfonctionnement du poêle dû à une mauvaise installation N utilisez pas de méthodes ou de matériaux improvisées qui pourraient compromettre l installation England s ne sera pas responsable des dommages indirects aux biens ou aux personnes qui résult...

Страница 41: ...male de 6 po L ouverture doit obligatoirement être couvert et le manchon d emboîtement soutenu par un support en tôle d acier d épaisseur n 24 au minimum D Longueur de cheminée préfabriquée à isolation pleine homologuée ayant un diamètre intérieur 2 po plus grand que le raccord et ayant au moins 1 po de revêtement isolant pour servir de gaine à un raccord à paroi simple en tôle d acier d épaisseur...

Страница 42: ... type de conduite votre concessionnaire local pourra vous recommander un entrepreneur qualifié pour cette installation C est la responsabilité du consommateur de s assurer que le conduit est sûr et en bon état de fonctionnement Le fabricant ne saura être tenu pour responsable d un éventuel accident causé par un appareil de chauffage raccordé à un conduit de fumée défectueux PROTECTION DU SOL ET DE...

Страница 43: ...ix proposé est de la brique de 4 po ayant un facteur C de 1 25 sur une planche de type minéral de 1 8 po ayant un coefficient K de 0 29 Étape a Servez vous de la formule ci dessus pour convertir les spécifications en valeur R R 1 k x T 1 0 84 x 0 75 0 893 Étape b Calculez le R du système proposé Brique de 4 po avec C 1 25 par conséquent le R de la brique 1 C 1 1 25 0 80 Planche de type minéral de ...

Страница 44: ... fixez les à l aide des vis fournies Voir l illustration 1 pour les dégagement avec et sans écrans thermiques latéraux Écran thermique arrière Écran thermique latéral Écran thermique latéral Illustration 3 installation de l écran thermique latéral et de la soufflante IMPLANTATION DES BRIQUES 1 non repéré sur le schéma brique de 9 x 4 x 11 4 po Qté 25 3 brique 4 x 2 1 2 x 11 4 po Qté 1 2 brique 4 x...

Страница 45: ...ement normal Pour lubrifier correctement le ventilateur utilisez un compte gouttes ou un dispositif semblable de distribution pour faire couler 5 à 7 gouttes d huile SAE 20 dans l orifice à cet effet situé sur le côté du moteur du ventilateur For our freestanding models with 30 in model number Para nuestros modelos de pie con 30 en el número de modelo Pour nos modèles sur pieds avec un numéro de m...

Страница 46: ...een the heat shield and the back of the stove s firewall Install using the same four screws that held the cover plate in place the plate will not be reinstalled The blower should be plugged into a 110 VAC power source and is controlled by the rheostat knob 2 Coloque el soplador orientando el ventilador de manera tal que el aire fluya hacia arriba y entre el protector térmico y la parte posterior d...

Страница 47: ...NSTALLATION 1 Enlevez toutes les pièces de l intérieur du poêle 2 Sélectionnez le meilleur emplacement pour le poêle Il est interdit d installer ces appareils à une distance inférieure au dégagement minimum par rapport à des matériaux combustibles représentés à l illustration 1 Le poêle doit obligatoirement être installé sur une surface non combustible comme indiqué par les illustrations 1 et 2 3 ...

Страница 48: ...rmale ce raccordement n est pas nécessaire bien qu il soit recommandé pour les maisons hermétiquement fermées Une trousse est offerte par England s Stove Works Inc elle est conçue pour raccorder cet appareil à l air comburant extérieur Pièce no AC OAK3 REPORTEZ VOUS AUX INSTRUCTIONS DU FABRICANT DE LA CHEMINÉE ET DU RACCORD DE CHEMINÉE Avertissement Installez VENT AU dégagements spécifiés PAR LA V...

Страница 49: ...ieur 2 Mettez un peu de papier froissé dans le poêle 3 Couvrez le papier avec une quantité généreuse de bois d allumage en forme de tipi ainsi que quelques morceaux de bois 4 Allumez ce combustible et fermez la porte presque complètement laissez la entrouverte 5 Ajoutez des morceaux de bois plus gros au fur et à mesure que le feu progresse en veillant à ne pas surcharger le poêle Ne remplissez pas...

Страница 50: ...NT Après une utilisation prolongée il pourra être nécessaire de remplacer le matériau qui assure l étanchéité de la vitre et de la porte s il perd sa souplesse Inspectez périodiquement les joints de la vitre et de la porte pour assurer qu ils assurent bien l étanchéité Si les joints s effilochent ou sont usés remplacez les immédiatement Prenez contact avec votre concessionnaire ou le service clien...

Страница 51: ...QU IL EST POUSSÉ À FOND À L ARRIÈRE DU POÊLE SANS ESPACE ENTRE LE PANNEAU ARRIÈRE ET LA PAROI ARRIÈRE Appelez le 800 245 6489 si vous avez des questions ENTRETIEN Cet appareil est équipé d un déflecteur de plafond en panneau de fibre de céramiques en deux parties Après une utilisation extensive il faut déposer et nettoyer le panneau Suivez les étapes ci dessous pour son nettoyage ou son remplaceme...

Страница 52: ...18 Positionnement des tubes de brûlage en inox pour tous les modèles de poêles 30 NC 50 SNC30 et 50 TNC30 ...

Страница 53: ...cuit 5 Établissez une routine pour la technique d allumage de chargement du bois et de brûlage Vérifiez tous les jours l absence de créosote jusqu à ce que l expérience vous indique à quelle fréquence le ramonage est nécessaire pour rester en sécurité N oubliez pas que plus un feu est chaud moins il se dépose de créosote et qu il peut y avoir besoin de faire un nettoyage par semaine en période de ...

Страница 54: ...duction de la fumée est un bon indicateur que le tirage a commencé dans la cheminée et qu une bonne combustion est désormais possible Vous pouvez maintenant ajouter de gros morceaux de bois sec quand il y a suffisamment de place pour eux dans le foyer Régler le régulateur d air à l ouverture désirée REMARQUE Moins le régulateur d air est ouvert plus longtemps le bois brûlera 2 Quel est le meilleur...

Страница 55: ...ité d air dans le domicile est suffisante ou pas évitez d utiliser ces appareils connus pour consommer de l air dans la mesure du possible ou ouvrez une porte ou une fenêtre pour permettre à l air d entrer dans le domicile FOURNISSEZ TOUJOURS UN APPORT EN AIR FRAIS DANS LA PIÈCE OÙ L UNITÉ EST INSTALLÉE LE NON RESPECT DE CETTE DIRECTIVE PEUT PRIVER LES AUTRES APPAREILS DE COMBUSTION D AIR ET CRÉER...

Страница 56: ... À RESSORT DE PORTE NICKEL AC SH4 POIGNÉE À RESSORT LAITON DU RÉGULATEUR D AIR AC SH4N POIGNÉE À RESSORT NICKEL DU RÉGULATEUR D AIR AC 03 POIGNÉE DE BAC À CENDRES LAITON AC 03BN POIGNÉE DE BAC À CENDRES NICKEL AC MCSP PEINTURE CHARBON DE BOIS HAUTE TEMPÉRATURE AC MBSP PEINTURE NOIRE HAUTE TEMPÉRATURE OPTIONS AC 30 SOUFFLANTE D AIR POUR LA PIÈCE AC 30SHSB SYSTÈME D ÉCRANS THERMIQUES LATÉRAUX NOIRS ...

Страница 57: ...ez un pied dans une fente et alignez le trou du pied avec le trou de la fente Fixez les pieds un à la fois à l aide des boulons et écrous fournis Bloquez solidement Pour installer un piédestal 1 Mettez les entretoises fournies entre les fentes du poêle et l embase du piédestal une entretoise passe de chaque côté du piédestal Alignez les quatre trous du piédestal 2 de chaque côté avec les trous des...

Страница 58: ...24 ...

Страница 59: ...tention de mauvaise installation de fonctionnement incorrect ou de réparations ou de tentatives de réparation non autorisées Le fabricant n est pas responsable des dommages intérêts immatériels indirects ou accessoires liés au produit y compris les éventuels coûts ou dépenses de fourniture d un équipement ou service de remplacement pendant les périodes de dysfonctionnement ou de non utilisation To...

Страница 60: ......

Страница 61: ...ix d achat ________________________ Numéro de série _____________________ Date de fabrication ______________________ Comment avez vous entendu parler de notre produit veuillez cocher une réponse ___ Bouche à oreille ___ Démonstration de la remorque ___ Internet Autre ____________________________________________________ Où avez vous reçu des renseignements au sujet de notre produit veuillez cocher ...

Страница 62: ......

Страница 63: ... détail ci après Le non respect des détails mentionnés pourrait réduire son rendement et causer des dommages matériels des blessures ou la mort Évitez d avoir recours à des expédients lors de l installation du système de ventilation England s Stove Works n est pas responsable des dommages causés par une installation incorrecte ou non sécuritaire Assurez vous de bien suivre toutes les instructions ...

Страница 64: ... 91 m 3 pi au dessus du point où son axe central traverse le toit ET la cheminée doit se terminer à 0 61 m 2 pi au dessus de toute partie du logement dans un rayon de 3 05 m 10 pi de la cheminée Fonctionnement et entretien Consultez les sections sur le fonctionnement mode d emploi et l entretien y compris le retrait et l élimination des cendres de votre guide d utilisation et suivez les directives...

Страница 65: ... fendre se tordre ou autrement changer de forme en séchant la plupart des bois doivent être séchés avant d être utilisés Le séchage à l air est la méthode la plus fréquemment utilisée pour le bois enstéré Dans la plupart des régions des États Unis la teneur en humidité minimale qu il est possible d obtenir par un séchage à l air est d environ 12 à 15 La plupart des matériaux séchés à l air ont une...

Страница 66: ...sécuritaires Une fois que votre appareil de chauffage au bois est correctement installé suivez ces directives pour assurer un fonctionnement sécuritaire Conservez tous les articles de maison inflammables draps meubles journaux et livres loin de l appareil Pour allumer un feu utilisez uniquement du papier journal du bois d allumage et un allume feu entièrement naturel ou biologique N utilisez jamai...

Страница 67: ... détecteur de fumée directement au dessus de l appareil pourrait causer des alarmes intempestives MISE EN GARDE Cet appareil est conçu pour fonctionner uniquement lorsque la porte est fermée L utilisation du poêle avec la porte ouverte provoquerait un refoulement de fumée et une combustion lente et inefficace De plus l utilisation de combustibles interdits peut être dangereuse et produire un excès...

Отзывы: