background image

This feature is compatible with the ENGL Z9 (which we recommend to use with this amp) and the 
ENGL Z12 only.

MIDI In

This 5-pin DIN port accepts data sent by a MIDI sender (ENGL Z9, ENGL Z12) or from or routed 
through another MIDI device.

CAUTION: 

Before you connect any 3

rd

 party MIDI footcontroller or effects device, always make sure

that the Phantom Power switch is not engaded to avoid damaging the connected device or the amp.

MIDI Channel Auto Recognition 

To assign the MIDI channel by which the amp´s MIDI system will receive program change or specific
MIDI controller commands assigned to certain amp functions you need to enter the MIDI Channel 
Auto Recognition.

This is how it works:
1.  The Clean channel must be engaged.
2. Press and hold the Noise Gate push button for about 2 seconds until the Noise Gate LED starts 

flashing fast.

3. Now send a PC (program change) or CC (control change) command on the desired MIDI channel 

(e.g. PC #1 on MIDI channel 1) to the amp. 

4. When receiving data, it gets confirmed by the store LED flashing 3 times short.
5. Now the amp is only listening to the MIDI channel (e.g. channel 1) that was formerly sent to the 

amp.

MIDI channel OMNI mode (receiving data on all 16 channels).

This is how it works:
1.  The Clean channel must be engaged.
2.  Press and hold the Noise Gate push button for about 2 seconds until the Noise Gate LED starts 

flashing fast.

3. Press and hold the store button for 2 seconds while the Noise Gate LED is flashing fast. 
4.  It gets confirmed by the store button LED flashing once long.
5.  Now the amp is receiving data from all channels.

MIDI Controller Numbers 

The E606SE accepts CC # messages to control most of the built-in functions, so that MIDI 
controllers #7 for example can be used to mute the output signal. This controller sends an Amp 
Mute command when assigned a value of 64 to 127. A value of 0 to 63 deactivates the Amp Mute 
command, thereby unmuting the amp and reactivating at its current Master volume setting. Most 
controllers switch functions on (64 to 127) and off (value 0 to 63), while other controllers are using
specific values from 0 to 127. One of these is CC #35, which controls the Reverb mix. 

Содержание Ironball SE E606SE

Страница 1: ...E606SE Ironball SE Operator s Manual...

Страница 2: ...nge voicing control of the preamp s passive EQ Treble Upper range voicing control of the preamp s passive EQ Lead Presence This control defines the Treble response in the poweramp stage for the Lead c...

Страница 3: ...ations for instance one for rhythm parts and the other for lead lines Press this push switch to activate deactivate the M V B function The red LED above this push button lights up to indicate that the...

Страница 4: ...op function The red LED above this push button lights up to indicate that the function is activated This feature can also be stored and switched via MIDI Noise Gate Press this push button to activate...

Страница 5: ...d value noise level at which the Noise Gate activates to suppress the signal The further you twist the knob to the right the higher the signal level at which the Noise Gate kicks in If you set the kno...

Страница 6: ...ry Mains Fuse Box The rear chamber contains the mains fuse and the front chamber a spare fuse NOTE Ensure replacement fuses bear identical ratings refer to the technical data CAUTION Always make sure...

Страница 7: ...ceiving data it gets confirmed by the store LED flashing 3 times short 5 Now the amp is only listening to the MIDI channel e g channel 1 that was formerly sent to the amp MIDI channel OMNI mode receiv...

Страница 8: ...pulse responses will be stored in alphabetical sequence to the slots 4 to 8 This is how it works 1 Connect your the amp via a USB B cable with your computer 2 Power the amp up and wait until the inter...

Страница 9: ...l and the Lead channel This works without having a MIDI footswitch and with or without having a TRS footswitch Z4 connected 1 Select a channel Clean or Lead 2 Select the IR you want to save to the cha...

Страница 10: ...adphone Output Connect a headphone 3 5mm 1 8 TRS for easy monitoring or practice When selecting the Power Soak Speaker Off position you can practice without disturbing your neighbours CAUTION When pow...

Страница 11: ...minal power output Power consumption approx 80 Watts 95 VA max Fuses 220 230 240 supply voltage 0 4 AT L T slow blow 100 115 120 supply voltage 0 8 AT L T slow blow Power Tube Fuses 2 x 0 08 AM M medi...

Страница 12: ...age your hearing and destroy speakers If you set the Volume or Master knobs to higher volume levels always make sure to back off amplification levels to prevent feedback by turning the Lead channel Ga...

Страница 13: ...eaker connected properly and are they functional Take all effect devices before the preamp FX Loop out of the signal chain Is the Noise Gate activated Relevant only if the amplifier is equipped with a...

Страница 14: ...nction of the packaging the outer packaging the device and the inner packaging must form a single unit This is the only way to ensure that the device survives the transport route undamaged Please chec...

Страница 15: ...a switch on the Z9 or Z12 4 Activate all desired functions on the map you want to add to your preset 5 Press and hold the Store push button for about 2 seconds to save the preset to the formerly sent...

Страница 16: ...www engl amps com...