8.6. 

The thruster stops working after a long period of use 

Intelligent electronic protection  
WARNING:

  

 

The system has intelligent monitoring to measure run and pause time. The XForce Thruster is not 
permitted to start if the voltage on the thruster is below 10.0V on 12V system/ 20.0V on 24V 
system. If the voltage at the thruster drops below 9.0/18.0V when thruster is running, warning will 
occur by showing orange light power light on the wireless control.  

 

 

Of security reasons, the system permits continuous running of the thruster in 4 intervals of 30 sec. 
After each interval, the thruster will stop. Switching off / on the joystick or switch panel will make the 
thruster run again. If repeated 4 times, (total 2 minutes running), the thruster will need to cool down 
for 25 minutes before being ready to run again. This to protect the motor and control unit against 
overheating. 

 

 

NB:

 In an emergency situation, to save the ship from any damage, this protection can be override 

by turning the main switch off and on. 

 

 

Check the thruster, control unit, fuse, cables and electric connections for visible signs of 
overheating, bad connection and short circuit. 

 

 

9. Installation of equipment with high currents. 

9.1. 

Special considerations. 

9.1.1. 

Preface/introduction. 

 

Engbo has experienced that over 90 % of our service-/problem enquieries, is related to power supply. 
This section has been made to try to address and help avoid the most common and known problems 
that can occur.  

 

In general, there are special considerations that must be taken into account regarding installation, use 
and maintenance of high current consumption equipment. It is therefore extremely important that only 
persons with the appropriate knowledge are doing this kind of work. 

 

 

The most common products which this document applies to are electrical bow and/or stern thrusters, 
windlasses and electrical starters for main and/or auxiliary engines. 

 

(Similar precautions must also be taken with generators and charging systems for batteries). 

 

 

Such equipment has, or can have for shorter periods, many hundreds of ampere of current 
consumption. 

 

In-rush current in an electrical motor of this kind will typically be around 2-3 times nominal current and 
can easily exceed 1000 A for short periods. Currents of these sizes will generate heat in all 
components, including cables.  

 

It is therefore very important that all components, including the connections of these components, are 
done correctly to keep the connection resistance and the total resistance in the electrical circuit as low 
as possible. 

 

 

All connections between cable-lug and components shall always be directly copper against copper, (or 
copper against brass). There shall never be any washers of any kind, or anything else, between the 
connections. 

 

 

Wrong or improper use or wrong connection of such high currents components will generate a lot of 
heat which in worst case can cause fire.  

 
 

Содержание XF 130 VR

Страница 1: ...v 4 2010 02 01 Page 1 XForce thruster VR series Installation and user manual XF 30 VR XF 60 VR XF 90 VR XF 130 VR English version According to NS EN ISO 9001 2000 FCC ID R78 RC 01 R78 ECU 01 Art no 117 00166 ...

Страница 2: ...ng the tunnel 13 4 1 9 Filler 13 4 1 10 Grinding 14 4 1 11 Directions for installations in high speed boats 14 4 1 12 Coating 14 5 THRUSTER INSTALLATION 15 5 1 The thrusters unit 15 5 2 Preparations 15 5 3 Not vertical installation 15 5 4 Off centre installation 16 5 5 Drilling thruster installation holes 16 5 6 Apply sealant 16 5 6 1 Specified sealants 16 5 7 Installation of the gearhousing 16 5 ...

Страница 3: ... are based on the same modules which makes it possible to manoeuvre and anchor using one single wireless remote control To achieve maximum benefit from your XForce thruster please study this manual thoroughly before installing and making use of the thruster panels Keep this manual onboard Do not hesitate to contact us if you have any questions Best regards Engbo AS P O Box 2288 Postterminalen N 31...

Страница 4: ...ow voltage The system has intelligent monitoring to measure run and pause time The XForce Thruster is not permitted to start if the voltage on the thruster is below 10 0V on 12V system 20 0V on 24V system If the voltage at the thruster drops below 9 0 18 0V when thruster is running warning will occur by showing orange power light on the wireless control Electronic protection system prevents the th...

Страница 5: ...and hand neck cord is included as standard easily removed The battery lifetime is more than 2 seasons based on normal leisure use IMPORTANT Always install at least one fixed XF Thruster panel 2 2 2 Operating instructions The remote control is battery operated To ensure longer life it will automatically go into sleep mode five minutes after the last button was pushed Deactivation is signalled with ...

Страница 6: ... short sounds if the remote is unable to communicate with the electronic unit If the thruster is overloaded and requires time to cool down this will also be indicated by quick red flashing These error indications are shown when buttons are pushed 2 2 4 RCU Remote Control Unit XF30VR XF60VR XF90VR and XF130VR are supplied with the power contactor fixed to the thruster motor and separate electronic ...

Страница 7: ...stand that coding is requested and automatically connect to your wireless control and the wireless remote control will immediately be ready for use This will be confirmed by a short sound signal and the green power light will turn from flashing to permanent Check that the wireless control is functioning Alt 2 Joystick installed Turn the thruster main switch off Disconnect the cables to the joystic...

Страница 8: ...al specifications wireless remote control Wireless remote Motor Control Unit Remote Control Unit Model RC 01 ECU 01 RCU Power supply 3 x 1 5 V DC 3 x AAA LR03 batteries From thruster integrated From thruster integrated Battery life 2 3 years normal leisure use Not applicable Not applicable Communication Two way narrowband GFSK modulation Operating frequency 868 075 869 125 MHz CE EU EFTA 902 175 9...

Страница 9: ...m Bmin mm C mm D mm E mm F mm XF 30VR 252 132 132 118 60 210 140 XF 60VR 295 185 185 145 60 210 150 XF 90VR 370 185 185 230 80 270 190 XF 130VR 385 250 250 320 100 270 190 3 3 Dimensions RCU Remote Control Unit RCU A mm B mm C mm D mm E mm F mm XF30VR XF60VR XF90VR and XF130VR 172 150 119 200 188 37 ...

Страница 10: ... holes in the hull Adapters for all thruster dimensions For more information ask your dealer or contact Engbo AS directly 4 1 2 Choosing and marking the location Select a suitable position for the bow thruster For best result make sure that the bow thruster is located as far forward and as low in the hull as possible To prevent air being drawn into the tunnel the upper part of the tunnel should be...

Страница 11: ...l centre hole Drill the centre holes diam 25mm for the tool centre tube on both sides of the hull Enter the tool centre tube through the hull from the outside and cut out the large holes from both sides It is important to cut with care by turning the tool several times making it possible for the cutting machine to work itself through the hull 4 1 5 Adapting the tunnel NB Please read point no 5 1 1...

Страница 12: ...ing a circular sanding disc to get adhesion for the polyester Vacuum clean and wipe down with acetone NB If the boat has a sandwich hull the core around the tunnel must be ground away sufficiently to allow the application of the glass fibre mat 4 1 7 Prevent filling from running out Should it be impossible to fit the tunnel with glass fibre all the way around the entire space beneath the tunnel mu...

Страница 13: ...ss is easier if the area between the tube and the hull is first smoothened out with glass fibre filler NB Make sure that any gap between the tunnel and the hull is completely filled with polyester glass fibre In areas difficult to reach a polyester glass fibre compound filler must be filled in NB To avoid any kind of misfitting of the thruster bracket there should be no glass fibre polyester where...

Страница 14: ...r installations in high speed boats On fast boats it may be necessary to make structural alterations to divert the flow of water in front of the tunnel This is to prevent water slamming into the propeller A Level with the hull B The tunnel should protrude 25 mm from the hull Example showing how to form the spoiler 4 1 12 Coating Prime the hull exterior with two coats of two component primer Apply ...

Страница 15: ...rizontal requires a support for the motor These instructions assume a tunnel has been correctly mounted in the hull 5 2 Preparations Start work from the inside Remove all possible remains from the moulding process and hone down with a file 5 3 Not vertical installation The bow thruster may be mounted at any angle from 0 90 The gearhousing must not be installed below the horizontal position To redu...

Страница 16: ...t Please refer to illustration left 5 6 Apply sealant Apply suitable sealant to the bracket and the bolts Make sure leakage is impossible NB Beware that the gear housing is prefilled with oil 5 6 1 Specified sealants Sikaflex 291 Würth Sealant 0890100 or similar Important Do not use sealant of hard caulk type 5 7 Installation of the gearhousing Guide the gear house through the tunnel hole Check th...

Страница 17: ... NB The propeller marked LH should be put on port side and the one marked RH on starboard side XF130VR Install the driver pin 1 into the hole in the propeller shaft 2 Fit the propeller 3 making sure the drive pin is located properly in the groove on the propeller 5 Fasten the propeller 3 with the locking nut 4 Locking nut torque M6 ab 8 Nm and M8 ab 20Nm Fastening the propeller Use a piece of wood...

Страница 18: ...ated in water Do not remove belt cover when power is connected NB All cables between the battery and the thruster motor should be kept as short as possible for optimum performance 6 1 Touch panel installation Decide where to place the panel Drill a Ø 15 mm hole Thread the panel cable trough the hole Clean the surface Remove the covering paper on the back of the panel and stick the panel onto the s...

Страница 19: ...place Check for good connection by pulling gently in the wires Correct connection is 1 White Direction 1 2 Brown Common 3 Green Direction 2 4 Yellow supply from 1 A fuse connected after thruster main switch or directly to MCU from MCU serial no 200473 and later 6 4 Connecting the control cable to the RCU The wires are connected by pressing in the button placed over the hole while the wire is being...

Страница 20: ...ct cable lengths and mount cable lugs in advance so that mounting the cables on the thruster can be done in a comfortable position before the unit is mounted in the boat NB Correct cable bolt nut torque is Terminal bolt M8 brass 10 Nm 7 4 lb ft Terminal bolt M10 brass 15 Nm 11 1 lb ft WARNING After connecting the cable on the motor treminal to the connection bolt with correct torque the bolt with ...

Страница 21: ...length is 1 5 m 5 ft Minimum cable insulation rating is 105 C 221 F To avoid overheating all connections between the power cable and components must be copper to copper or copper to brass No washers of any kind shall be mounted between the power cable lug and the copper bar component 6 8 Fuse connections The picture shows the correct power cable connection to the fuse terminal Note that the fuse i...

Страница 22: ...60 1 10 1 33 70 2 0 115 Ah 12 V 800 350 12 00350 XF60VR 24 4 60 1 10 1 33 70 2 0 115Ah 24 V 800 300 12 00300 XF90VR 12 5 90 1 10 1 33 95 3 0 115 Ah 12 V 1700 400 12 00400 XF90VR 24 5 90 1 10 1 33 95 3 0 150 Ah 24 V 1050 350 12 00350 XF130VR 24 7 130 1 10 1 33 120 4 0 175 Ah 24 V 1150 400 12 00400 1 The distance from the thruster unit to the battery one way each cable Use of even larger cable dimen...

Страница 23: ...ied out 7 1 Mechanical check Check for loose bolts supports covers and cable supports Check the propeller 7 2 Corrosion check An inadequate configuration of the on board electric system can result in galvanic corrosion electrolysis Use of shore power combined with ground fault will some times accelerate the process This will lead to corrosion of the metal components Periodic inspection of gearhous...

Страница 24: ...ibed below Short between terminal 1 and 2 on the control unit and the motor will run in one direction Short between 2 and 3 and the motor will run in the opposite direction Measure zero resistance with wires disconnected from the control unit between the green and brown wire and between the brown and white wire from the joystick operator panel when operating the lever switch This test will show wh...

Страница 25: ...uster now works normal check the cable connections between the control unit and the joystick If the thruster still does not work study point 8 5 8 4 The thruster runs in contradicting direction If the operating direction when using the remote transmitter is wrong follow the procedure below Turn off the main switch Remove the rubber cover on the Control Unit Change position on DIL switch 8 on S100 ...

Страница 26: ...o power supply This section has been made to try to address and help avoid the most common and known problems that can occur In general there are special considerations that must be taken into account regarding installation use and maintenance of high current consumption equipment It is therefore extremely important that only persons with the appropriate knowledge are doing this kind of work The m...

Страница 27: ...for recommended relation between size and length Generally speaking a thicker cable dimension will give better performance especially with longer cables Use only cable lugs of high quality These must only be mounted on the cables with correct tool and correct according to the procedure from the cale lug manufacturer Never use a vise wrench or similar to press on a cable lug Although it may look li...

Страница 28: ...use and the cable lug Correct torque for a Stainless Steel bolt A4 is 20 Nm 9 2 4 Main switch connection The bolt itself is an active current conductor The pictures show a correct main switch connection Please note that the cable lug is mounted directly onto the terminal post washer and nut is on top of the cable lug Different kinds of main switches with different kinds of terminals excist Correct...

Отзывы: