ENFORCER Room Occupancy Monitor 

SECO-LARM U.S.A., Inc. 

3

 

Basic DIY Installation Using Micro USB Power:  

Installation Notes:  

 

1.

 

Find a suitable location to mount the Sensor/ 
Indicator near a power source. Keep in mind 
that the included micro USB cord is 12" long. 

2.

 

Use a paper clip and program as needed. 
See 

Setting a Reminder Time

 and 

Expanding 

the Room Monitor System

 (pgs. 4~5). 

3.

 

Apply double-sided mounting tape to the 
back of the Sensor/Indicator and mount. 

4.

 

Connect the micro USB plug to the 
Sensor/Indicator and connect to power. 

Power 

source 

12" 

(30cm) 

The Room Monitor Kit (RM-R100-KB1Q) is pre-learned and ready to go right out of the box. Just 
mount and connect to power via the included micro USB cable and any USB adapter. Follow the 
steps below for a basic installation. 

 

Mount the Sensor and Indicator in locations where they are not exposed to weather or moisture, 
and where they are not surrounded by metal. Metal will block the RF signal, resulting in reduced 
range. 

 

For best results, mount the Sensor and Indicator with no more than one wall in between the two.

 

If using USB power, make sure to replace the cover before connecting to the mini USB port. 

 

The door contact input should only be used for applications where the door being monitored is 
usually kept open. 

 

If an N.C. magnetic contact is being used to monitor the door then a 100kD resistor (not 
included) should be installed between the voltage and door contact inputs. See pg. 6, 

Using a 

Magnetic Contact for Door Monitoring,

 for more details. 

Содержание ECO-LARM RM-R100-TLQ

Страница 1: ...le built in buzzer for service input Programmable reminder 3 30 min Simple to install micro USB or terminal block 5 12VDC Suitable to use in restrooms fitting rooms etc to monitor occupancy Indicators can be paired with up to 15 Sensors per channel Each sensor can transmit to unlimited number of indicators Service button connections available RM R100 TLQ and RM R100 RB1Q only ...

Страница 2: ...it RM R100 KB1Q Overview Pairing button Micro USB Power input PIR Sensor Phototransistor LED Indicator Phototransistor ON OFF jumper LED ON OFF jumper PIR ON OFF jumper Sensor Wire pass through See Wiring Using Screw Terminals on pg 6 for details Service pairing button 1 Room Indicator Ch2 Pairing button 2 Room Indicator Ch1 Pairing button Micro USB power input LED Indicators Antenna Buzzer 1 Room...

Страница 3: ...and connect to power via the included micro USB cable and any USB adapter Follow the steps below for a basic installation Mount the Sensor and Indicator in locations where they are not exposed to weather or moisture and where they are not surrounded by metal Metal will block the RF signal resulting in reduced range For best results mount the Sensor and Indicator with no more than one wall in betwe...

Страница 4: ...icator Sensor RM R100 TLQ Service paring button Ch1 Pairing button LED Indicators 1 Room Indicator RM R100 RB1Q Ch1 Pairing button LED Indicators Ch2 Pairing button 2 Room Indicator RM R100 R2Q To clear all codes from a channel s memory press the channel s pairing button for 3 seconds or more until the channel indicator LED begins flashing Release and then press the button again for 3 seconds or m...

Страница 5: ...nsors or Indicator Remote buttons NOTES The channel s LED indicator will flash a maximum of 30 seconds If no device is paired during this time the Indicator will automatically exit learning mode and the LED will turn off If the Sensor or Indicator Remote button being paired has already been paired before the channel indicator LED will turn steady ON and then start flashing The Sensor button will n...

Страница 6: ...tallation and drill a hole to run wires 2 Remove the bottom case and PCB and feed the wires through the wire pass through holes PCB and case and wire as indicated below 3 Replace the top cover and mount Wire pass through Door N O input DNO GND Service output SOP V 5 12 VDC Service input N O SIP Sensor RM R100 TLQ V 5 12 VDC GND 2 Room Indicator RM R100 R2Q GND Service input N O SIP V 5 12 VDC 1 Ro...

Страница 7: ...00 30m Operating frequency 433 92MHz Operating voltage 5VDC via micro USB or 5 12 VDC via terminal block Connections Screw terminals Operating temperature 4 167 F 20 75 C Dimensions 21 2 x15 16 x17 8 64x24x48 mm Weight 1 8 oz 50g Specifications The Sensor s PIR sensor can detect movement up to 16ft 5m However be sure to take into account the height and angle at which the transmitter is mounted Ref...

Страница 8: ...r abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to the replacement or repair only at SECO LARM s option In no e...

Отзывы: