ENFORCER Room Occupancy Monitor
SECO-LARM U.S.A., Inc.
3
Basic DIY Installation Using Micro USB Power:
Installation Notes:
1.
Find a suitable location to mount the Sensor/
Indicator near a power source. Keep in mind
that the included micro USB cord is 12" long.
2.
Use a paper clip and program as needed.
See
Setting a Reminder Time
and
Expanding
the Room Monitor System
(pgs. 4~5).
3.
Apply double-sided mounting tape to the
back of the Sensor/Indicator and mount.
4.
Connect the micro USB plug to the
Sensor/Indicator and connect to power.
Power
source
12"
(30cm)
The Room Monitor Kit (RM-R100-KB1Q) is pre-learned and ready to go right out of the box. Just
mount and connect to power via the included micro USB cable and any USB adapter. Follow the
steps below for a basic installation.
•
Mount the Sensor and Indicator in locations where they are not exposed to weather or moisture,
and where they are not surrounded by metal. Metal will block the RF signal, resulting in reduced
range.
•
For best results, mount the Sensor and Indicator with no more than one wall in between the two.
•
If using USB power, make sure to replace the cover before connecting to the mini USB port.
•
The door contact input should only be used for applications where the door being monitored is
usually kept open.
•
If an N.C. magnetic contact is being used to monitor the door then a 100kD resistor (not
included) should be installed between the voltage and door contact inputs. See pg. 6,
Using a
Magnetic Contact for Door Monitoring,
for more details.