ENFORCER Room Occupancy Monitor 

2

 

SECO-LARM U.S.A., Inc. 

The ENFORCER Room Monitor can be used to monitor the occupancy status of rooms in high 
traffic areas: restrooms, fitting rooms, etc. The Room Monitor uses PIR and phototransistor 
sensors to monitor the occupancy of a room. The 1-Room Indicator includes additional features, 
such as a built-in buzzer and service button input, for applications where occupants may need 
assistance. The 2-Room Indicator is ideal for monitoring multiple rooms at once. 

Introduction:  

What's Included in the Room Monitor Kit (RM-R100-KB1Q):  

 

 

 

 

 

 

 

 

 

   

Overview:  

Pairing button 

Micro USB Power input 

PIR Sensor

Phototransistor

LED Indicator 

Phototransistor ON/OFF jumper* 

LED ON/OFF jumper* 
 

PIR ON/OFF jumper*

Sensor 

Wire pass-through

See "Wiring Using Screw Terminals" on pg. 6 for details 

Service pairing button (1-Room Indicator) / Ch2 Pairing button 
 

(2-Room Indicator) 

Ch1 Pairing button 

Micro USB power input 
 

LED Indicators** 

Antenna 

Buzzer 

(1-Room Indicator only)  

Buzzer ON/OFF jumper* (1-Room Indicator only) 

Indicators 

*Phototransistor jumper's default is OFF, other jumpers' default is ON 

**2-Room Indicator has 4 LED indicators (2 for each channel). 

Wire pass-through 
 

See "Wiring Using Screw Terminals" on pg. 6 for details 

1x  Sensor 

1x  1-Room Indicator 

2x  USB Power cords 

 

 

 

 

 

 

1x  Indicator decal 

1x  Manual 

 

 

 

 

 

 

 

 

 

2

Содержание ECO-LARM RM-R100-TLQ

Страница 1: ...le built in buzzer for service input Programmable reminder 3 30 min Simple to install micro USB or terminal block 5 12VDC Suitable to use in restrooms fitting rooms etc to monitor occupancy Indicators can be paired with up to 15 Sensors per channel Each sensor can transmit to unlimited number of indicators Service button connections available RM R100 TLQ and RM R100 RB1Q only ...

Страница 2: ...it RM R100 KB1Q Overview Pairing button Micro USB Power input PIR Sensor Phototransistor LED Indicator Phototransistor ON OFF jumper LED ON OFF jumper PIR ON OFF jumper Sensor Wire pass through See Wiring Using Screw Terminals on pg 6 for details Service pairing button 1 Room Indicator Ch2 Pairing button 2 Room Indicator Ch1 Pairing button Micro USB power input LED Indicators Antenna Buzzer 1 Room...

Страница 3: ...and connect to power via the included micro USB cable and any USB adapter Follow the steps below for a basic installation Mount the Sensor and Indicator in locations where they are not exposed to weather or moisture and where they are not surrounded by metal Metal will block the RF signal resulting in reduced range For best results mount the Sensor and Indicator with no more than one wall in betwe...

Страница 4: ...icator Sensor RM R100 TLQ Service paring button Ch1 Pairing button LED Indicators 1 Room Indicator RM R100 RB1Q Ch1 Pairing button LED Indicators Ch2 Pairing button 2 Room Indicator RM R100 R2Q To clear all codes from a channel s memory press the channel s pairing button for 3 seconds or more until the channel indicator LED begins flashing Release and then press the button again for 3 seconds or m...

Страница 5: ...nsors or Indicator Remote buttons NOTES The channel s LED indicator will flash a maximum of 30 seconds If no device is paired during this time the Indicator will automatically exit learning mode and the LED will turn off If the Sensor or Indicator Remote button being paired has already been paired before the channel indicator LED will turn steady ON and then start flashing The Sensor button will n...

Страница 6: ...tallation and drill a hole to run wires 2 Remove the bottom case and PCB and feed the wires through the wire pass through holes PCB and case and wire as indicated below 3 Replace the top cover and mount Wire pass through Door N O input DNO GND Service output SOP V 5 12 VDC Service input N O SIP Sensor RM R100 TLQ V 5 12 VDC GND 2 Room Indicator RM R100 R2Q GND Service input N O SIP V 5 12 VDC 1 Ro...

Страница 7: ...00 30m Operating frequency 433 92MHz Operating voltage 5VDC via micro USB or 5 12 VDC via terminal block Connections Screw terminals Operating temperature 4 167 F 20 75 C Dimensions 21 2 x15 16 x17 8 64x24x48 mm Weight 1 8 oz 50g Specifications The Sensor s PIR sensor can detect movement up to 16ft 5m However be sure to take into account the height and angle at which the transmitter is mounted Ref...

Страница 8: ...r abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to the replacement or repair only at SECO LARM s option In no e...

Отзывы: