WIRING DIAGRAM

OPTIONAL ACCESSORIES
A. Piezo siren
B. 12VDC adapter
C. 9VDC stand-by battery

9VDC

RED

GREEN

Telephone line

(must connect when

testing dialer)

A

B

C

*

IMPORTANT

:

 

Triggers on open circuit.

If either trigger wire is not used, it must be

grounded. If not, the unit will operate.

Note: You can program telephone
numbers and voice messages prior to
connecting power as long as the 9VDC
battery is inserted.  The stand-by
battery will retain programmed
information and allow for
approximately 24 hours of operation.

1.Select a location for the dialer that is

near both an AC outlet and the alarm
control panel.  Keep the E-920A out of
sight of intruders.

2.Connect to power:

a. If the dialer is to draw power from the

alarm control panel, connect the red,

black, yellow, and green wires of the

4-pin connector to the panel as shown

in the wiring diagram.

b. If local power is preferred, plug in an

optional 12VDC adapter.  It is not

necessary to connect the red wire of

the 4-pin connector to the alarm

control panel.  However, the black,

yellow, and green wires MUST be

connected.

c. For backup power, connect both the

red wire and the 12VDC adapter.

Note: The E-920A utilizes an EEPROM
to retain memory even in the event of
a power loss.

3.Two trigger inputs can be connected to

two separate alarm control panel trigger
outputs.  Each trigger input has its own
voice message. The yellow wire (trigger
input #1) is for the first voice message,
and the green wire (trigger input #2) is
for the second voice message.  The
messages should reflect the type of
emergency which the alarm's output
represents.  The green and yellow wires
should be connected to separate N.C.
dry contacts on the alarm.

Note: If DIP Switch 5 is set in the OFF
position, the N.C. contact for trigger
input #1 or #2 must remain open in
order for the dialer to complete the
dialing cycle.  In this case, the dialer
must be connected to a triggering
device with a timed output.

4.The dialer can be connected to a pulse

or touch-tone phone line via the included
telephone cable.

5. Once all connections have been made,

the unit is ready to be programmed.

CONNECTING THE E-920A

RED (+12VDC ONLY) (optional)
BLACK (common (-) ground, must connect)
YELLOW (trigger 1, message 1) N.C.* (GND)
GREEN (trigger 2, message 2) N.C.* (GND)

Note: If the red
wire is connected to
the alarm control
panel's +12VDC
output, the adapter
is optional.

12VDC

adapter

Содержание E-920A

Страница 1: ...ng through all unanswered numbers until the full message was delivered to each number two times Note If the number of a voice pager service which requires operator assistance is used the service shoul...

Страница 2: ...one no M VOICE button For recording voice message N DIP Switches 1 Exit delay 1 or 120 seconds 2 Entrance delay 1 or 30 seconds 3 Tone pulse telephone 4 Regular PBX telephone 5 Trigger input 2 time re...

Страница 3: ...connected c For backup power connect both the red wire and the 12VDC adapter Note The E 920A utilizes an EEPROM to retain memory even in the event of a power loss 3 Two trigger inputs can be connecte...

Страница 4: ...alarm panel which has a programmed entry exit delay both DIP switches should be placed in the ON position which provides an instant response to any trigger 3 DIP SWITCH 3 TELEPHONE DIAL OUT TYPE a ON...

Страница 5: ...RY LOCATIONS 1 THROUGH 4 Note The memory locations can be programmed in any order and skipped as needed New numbers entered for a memory location completely erase and replace old numbers previously st...

Страница 6: ...tton to set the dialer to PROGRAM mode 2 Press the MEMORY button TO STORE A PAGER NUMBER VOICE MESSAGE AND OR NUMERIC CODE 1 Press the MODE button to set the dialer to PROGRAM mode 2 While checking fo...

Страница 7: ...must be held down for the entire time of the recording 5 As soon as the voice key is released or when 16 seconds have passed the word VOICE will disappear from the LCD This indicates that the message...

Страница 8: ...he SELF TEST function allows for message and data confirmation without connecting the E 920A to a telephone line To ensure the correct telephone numbers and recorded messages have been programmed prop...

Отзывы: