![Enfora Enabler IIG Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/enfora/enabler-iig/enabler-iig_integration-manual_2411837022.webp)
GSM0128IG001
21
Revision Draft – 9/22/08
5.4 Transmit Power
Enfora Enabler IIG module
Power Class
Transmit Power
1900 MHz
1800 MHz
GSM Power Class 1
1-W conducted power maximum (30
dBm +/- 2 dB), measured at the
antenna port
850 MHz
900 MHz
GSM Power Class 4
2-W conducted power maximum
(33 dBm +/- 2 dB),
measured at the antenna port
5.5 Receiver Sensitivity
Enfora Enabler IIG module
Sensitivity
Mode
1900 MHz
1800 MHz
-106 dBm (typical)
GPRS Coding Scheme 1 (CS1)
900 MHz
850 MHz
-106 dBm (typical)
GPRS Coding Scheme 1 (CS1)
5.6 Radio Power/Reset
Low is modem OFF. High is modem ON.
Radio Power/Reset
Parameter/Conditions
MIN TYP MAX UNIT
V
IL
Input Voltage - Low
-0.5 0.9 Vdc
V
IH
Input Voltage - High
2.0 3.4 Vdc