![Enfora Enabler IIG Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/enfora/enabler-iig/enabler-iig_integration-manual_2411837021.webp)
GSM0128IG001
20
Revision Draft – 9/22/08
5.3 Operating Power
The Enfora Enabler IIG module requires an input voltage of 3.3 Vdc to 4.5 Vdc.
5.3.1
GSM Operating Power
GSM Operation
Input Current
Band
Mode
Low
Nom/Avg
High/Peak
Units
1900
1 RX/1 TX, Full Power
205
1225
mA
1800
205
1300
mA
900
245
1650
mA
850
255
1750
mA
ALL
Peaks are
based on
Average
DRX2
4.7
<5
mA
DRX5
2.65
<5
DRX9
2.1
<5
N/A
Shutdown
~ 50
uA
5.3.2
GPRS Operating Power
GPRS Operation
Input Current
Band
Mode
Low
Nom/Avg
High/Peak
Units
1900
4 RX/1TX, Full Power
240
1250
mA
2 RX/2TX, Full Power
340
1250
mA
1 RX/1TX, Full Power
195
1225
mA
1800
4 RX/1TX, Full Power
240
1325
mA
2 RX/2TX, Full Power
345
1325
mA
1 RX/1TX, Full Power
195
1300
mA
900
4 RX/1TX, Full Power
275
1650
mA
2 RX/2TX, Full Power
425
1675
mA
1 RX/1TX, Full Power
235
1650
mA
850
4 RX/1TX, Full Power
275
1725
mA
2 RX/2TX, Full Power
440
1750
mA
1 RX/1TX, Full Power
240
1700
mA
ALL
Peaks are
based on
Average
DRX2
4.7
<5
mA
DRX5
2.65
<5
mA
DRX9
2.1
<5
mA
N/A
Shutdown
~ 15
uA