62
Euromax Pellet Stove Installation and Operation Manual
Power was interrupted while the stove was functioning.
After the cool down cycle, the
stove will restart using the last settings. Press “RESET” to go back to the Main Status
Page.
Note:
For a short power failure (less than 5 seconds), the stove will continue to function at the
selected speed.
9.3.9 Smoke Smell
Venting system leaks.
Inspect all vent connections. This is a pressurized venting system.
All vent connector joints must be sealed and fastened in accordance with the pellet vent
manufacturer's instructions to ensure consistent performance and avoid smoke and ash
spillage
(see
Section 4.5.1:
Installation Warnings, Cautions and Recommendations
Reminder
).
Worn gaskets.
Gaskets may be allowing smoke spillage (doors, clean out traps, etc).
Make sure that all gaskets are in good condition and replace them with original parts if
necessary. Make sure the door is well adjusted (see
Section 8.1.9
Door Adjustment
).
Negative pressure.
A faint wood-burning odor during ignition or shut down is normal.
Although, if this increases beyond what is considered normal or if you notice an unusual
soot build-up on walls or furniture, check your venting system carefully for leaks and make
sure all gaskets are in good condition. The stove exhaust blower produces a negative
pressure in the room. It draws air from the inside of the room, through the stove and then
outdoors. In the same manner, other appliances can also create a larger negative
pressure. In this case, as the air naturally flows from a high pressure point to a low
pressure point, a larger negative pressure can draw smoke from the inside of the stove
into the room. The stove can also be affected by other mechanical ventilation systems,
causing the same effect as mentioned previously. Using a fresh air intake will prevent
negative pressure (see
Appendix E:
Combustion Air supply
).
Also, make sure the
recommended maintenance schedule has been followed.
Содержание Euromax EP00070
Страница 64: ...64 Euromax Pellet Stove Installation and Operation Manual 10 Wiring Diagram ...
Страница 76: ...76 Euromax Pellet Stove Installation and Operation Manual 15 Exploded View and Replacement Parts SECTION A ...
Страница 77: ...Euromax Pellet Stove Installation and Operation Manual 77 SECTION B ...
Страница 78: ...78 Euromax Pellet Stove Installation and Operation Manual SECTION C ...
Страница 79: ...Euromax Pellet Stove Installation and Operation Manual 79 SECTION D SECTION E ...
Страница 80: ...80 Euromax Pellet Stove Installation and Operation Manual SECTION F SECTION G ...
Страница 81: ...Euromax Pellet Stove Installation and Operation Manual 81 SECTION H SECTION I ...
Страница 82: ...82 Euromax Pellet Stove Installation and Operation Manual SECTION J SECTION K ...