Euromax Pellet Stove Installation and Operation Manual
9.3.6 Unit Overheat
Inadequate fuel is used.
Remove the burn pot, make sure that all openings are clear and
check that no ash has filled the tube around the igniter. Refer to the maintenance section.
Also, make sure that the recommended fuel is used (see
Section 5.2.1
Proper Fuel
).
The flue is not properly installed.
Make sure the venting system meets the criteria in the
Section 4: Venting System
as well as the venting system manufacturer’s instructions.
The flue is blocked or needs cleaning.
One of the following components is obstructed or
blocked; air intake shutter, combustion blower, burn pot, heat exchangers and channels,
exhaust blower and or venting system. Refer to
Section 8: Maintenance
.
The stove needs maintenance.
Refer to
Section 8: Maintenance
.
The burn pot is not installed properly.
Make sure the burn pot is installed correctly (see
Section 8.1.4: Cleaning the Burn Pot)
.
The baffle is not installed properly or holes may be blocked
. Make sure the baffle is
well installed and the lock is in place. Make sure the holes are clear. (see
Section 8.1.2:
Cleaning the Baffle, the Heat Exchanger and the Combustion Chamber
).
The convection blower is defective.
Go to the troubleshooting page on the LCD screen
and test the convection blower (see
Section 9.2
Testing Components
).
The convection blower needs maintenance.
Carefully clean blower housing and make
sure blower louvers are not blocked.
NOTE: IF THE CODE APPEARS MORE THAN THREE TIMES, THE LCD SCREEN WILL
LOCK ITSELF UP.
THIS PELLET STOVE IS EQUIPED WITH MULTIPLE DEVICES TO ENSURE YOUR
SAFETY. IF A WARNING ERROR CODE STOPS YOUR STOVE ON SEVERAL
OCCASIONS, IT IS MORE THAN LIKELY THAT THE STOVE DOES NOT EXHAUST
PROPERLY.
Before resetting the PC-board displaying an error code, do a
COMPLETE stove maintenance as described in this manual.
For an Overheat Code
•
Service the stove COMPLETELY as described in this manual. See section 8:
Maintenance
•
Verify the venting system and all other components mentioned above.
Содержание Euromax EP00070
Страница 64: ...64 Euromax Pellet Stove Installation and Operation Manual 10 Wiring Diagram ...
Страница 76: ...76 Euromax Pellet Stove Installation and Operation Manual 15 Exploded View and Replacement Parts SECTION A ...
Страница 77: ...Euromax Pellet Stove Installation and Operation Manual 77 SECTION B ...
Страница 78: ...78 Euromax Pellet Stove Installation and Operation Manual SECTION C ...
Страница 79: ...Euromax Pellet Stove Installation and Operation Manual 79 SECTION D SECTION E ...
Страница 80: ...80 Euromax Pellet Stove Installation and Operation Manual SECTION F SECTION G ...
Страница 81: ...Euromax Pellet Stove Installation and Operation Manual 81 SECTION H SECTION I ...
Страница 82: ...82 Euromax Pellet Stove Installation and Operation Manual SECTION J SECTION K ...