8
Destination 2.3 Insert Installation and Operation Manual
2 General Information
2.1 Performances
(1)
Model
Destination 2.3 (EB00044)
Fuel type
Dry cordwood
Recommended heating area
[*]
500 to 2,100 ft
2
(47 to 195 m
2
)
Overall firebox volume
(2)
2.4 ft
3
(0.068 m
3
)
EPA loading volume
1.95 ft
3
(0.055 m
3
)
Maximum burn time
[*]
8 hours
Maximum heat output (dry cordwood)
(3)
75,000 BTU/h (22.0 kW)
Overall heat output rate (min. to max.)
(3)(4)
14,200 BTU/h to 44,500 BTU/h
(4.16 kW to 13.04 kW)
Average overall efficiency
(4)
- Dry cordwood
72% (HHV)
5
77% (HHV)
5
Optimum overall efficiency
(3)(7)
79%
Optimum heat transfer efficiency
(8)
76%
Average particulate emissions rate
(9)
2.3 g/h (EPA / CSA B415.1-10)
(10)
Average CO
(11)
69 g/h
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft, heat loss
factors, climate, fuel type and other variables. The recommended heated area for a given appliance is defined by the
manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a
power failure.
(1)
Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn
time and maximum heat output.
(2)
The overall firebox calculation is an approximation and is not intended to be used for loading. This volume includes a
buffer zone to allow an easier fuel insertion, prevent ash spillage and allow the air wash to work properly.
(3)
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft
3
and 20 lb/ft
3
.
Other performances are based on a fuel load prescribed by the standard. The specified loading density varies
between 7 lb/ft³ and 12 lb/ft
3
. The moisture content is between 19% and 25%.
(4)
As measured per CSA B415.1-10 stack loss method.
(5)
Higher Heating Value of the fuel.
(6)
Lower Heating Value of the fuel.
(7)
Optimum overall efficiency at a specific burn rate (LHV).
(8)
The optimum heat transfer efficiency is for the low burn rate and represents the appliance's ability to convert the
energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into
account the chemical losses during combustion.
(9)
This appliance is officially tested and certified by an independent agency.
(10)
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17.
Based on ALT-125 sent by EPA on February 28th, 2018.
(11)
Carbon monoxide.
Содержание Destination 2.3
Страница 6: ...6 Destination 2 3 Insert Installation and Operation Manual CERTIFICATION PLATE ...
Страница 10: ...10 Destination 2 3 Insert Installation and Operation Manual 2 3 Dimensions ...
Страница 46: ...46 Destination 2 3 Insert Installation and Operation Manual ...
Страница 48: ...48 Destination 2 3 Insert Installation and Operation Manual Appendix 5 Log retainers installation 1 2 3 ...
Страница 52: ...52 Destination 2 3 Insert Installation and Operation Manual Appendix 8 Exploded Diagram and Parts List ...
Страница 55: ...Destination 2 3 Insert Installation and Operation Manual 55 ...
Страница 56: ...56 Destination 2 3 Insert Installation and Operation Manual ...