Destination 2.3 Insert Installation and Operation Manual
29
8 Safety Information and Standards
•
THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE APPLIANCE ALWAYS
OVERRIDES THE INFORMATION PUBLISHED, IN ANY OTHER MEDIA (OWNER’S MANUAL, CATALOGUES,
FLYERS, MAGAZINES AND/OR WEB SITES).
•
MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING COMPONENTS MAY
RESULT IN HAZARDOUS CONDTIONS. WHERE ANY SUCH CHANGES ARE PLANNED, STOVE BUILDER
INTERNATIONAL INC. SHOULD BE CONTACTED IN ADVANCE.
•
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING
AUTHORITY VIOLATES CSA B365 (CANADA), AND ANSI NFPA 211 (USA).
•
CONNECT THIS INSERT ONLY TO A LISTED STAINLESS STEEL CHIMNEY LINER FOR USE WITH SOLID FUEL.
•
IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE ROOM.
•
CAUTION: DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK
UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.
•
CAUTION: DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
•
THE INSERT AND ITS STAINLESS STEEL CHIMNEY LINER ARE TO BE INSTALLED ONLY WITHIN A LINED
MASONRY CHIMNEY AND MASONRY FIREPLACE CONFORMING TO BUILDING CODES FOR USE WITH
SOLID FUEL. DO NOT REMOVE BRICKS OR MORTAR FROM THE EXISTING FIREPLACE WHEN INSTALLING
THE INSERT.
•
TO BE INSTALLED AS A FREESTANDING ROOM HEATER WITH THE CLEARANCES IN THE
MANUFACTURER'S INSTALLATION INSTRUCTIONS. IT IS STRICTLY FORBIDDEN TO INSTALL THIS ROOM
HEATER IN ANY FACTORY-BUILT FIREPLACE.
8.1 Regulations Covering Insert Installation
When installed and operated as described in these instructions, the Destination 2.3 wood insert is
suitable for use in residential installations. The Destination 2.3 wood insert is not intended for
installation in a bedroom.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and
the CSA C22.1 Canadian National Electrical Code are to be followed in the absence of local code
requirements. In the USA, the ANSI NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid
Fuel-Burning Appliances and the ANSI NFPA 70 National Electrical Code are to be followed in the
absence of local code requirements.
This insert must be installed with a continuous chimney liner of 6” diameter extending from the insert
to the top of the chimney. The chimney liner must conform to the Class 3 requirements of CAN/ULC-
S635, Standard for Lining Systems for Existing Masonry or Factory-built Chimneys and Vents, or
CAN/ULC-S640, Standard for Lining Systems for New Masonry Chimneys.
The Insert is not approved for use with a so-called “positive flue connection” to the clay tile
of a masonry chimney.
Содержание Destination 2.3
Страница 6: ...6 Destination 2 3 Insert Installation and Operation Manual CERTIFICATION PLATE ...
Страница 10: ...10 Destination 2 3 Insert Installation and Operation Manual 2 3 Dimensions ...
Страница 46: ...46 Destination 2 3 Insert Installation and Operation Manual ...
Страница 48: ...48 Destination 2 3 Insert Installation and Operation Manual Appendix 5 Log retainers installation 1 2 3 ...
Страница 52: ...52 Destination 2 3 Insert Installation and Operation Manual Appendix 8 Exploded Diagram and Parts List ...
Страница 55: ...Destination 2 3 Insert Installation and Operation Manual 55 ...
Страница 56: ...56 Destination 2 3 Insert Installation and Operation Manual ...