Symbol Legend

The following terms are used throughout this manual to bring 
attention to the presence of potential hazards, or to important 
information concerning the product.

DANGER

: Indicates an imminent hazardous 

situation which, if not avoided, will result in death, 
serious injury or substantial property damage.

WARNING

: Indicates an imminent hazardous 

situation which, if not avoided, may result in 
personal injury or property damage.

DANGER

: Indicates an imminent electrical shock 

hazard which, if not avoided, will result in death, 
serious injury or substantial property damage.

How to use this manual

 

This installation manual does not contain any system design 

documentation. System design documentation is available 

from any authorized ENERVEX representative. Accessories, 

fans, and variable frequency drives are not covered by 

this manual. Please refer to these component’s individual 
manuals.

TO REDUCE THE RISK OF FIRE, 
ELECTRICAL SHOCK OR INJURY TO 
PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit in the manner intended by the manufacturer.   
  If you have questions, contact the manufacturer at the    
  address or telephone number listed on the front of the   
  

manual.

2. Before servicing or cleaning the unit, switch off at service  
  panel and lock service panel to prevent power from being  
  switched on accidentally.

3. Installation work and electrical wiring must be done by a  
  qualified person(s) in accordance with applicable codes   
  and standards.

4.  Follow the appliance manufacturer’s guidelines and safety   
  standards such as those published by the National Fire   
  Protection Association (NFPA), and the American Society  
  for Heating, Refrigeration and Air Conditioning Engineers  
  (ASHRAE), and the local code authorities.

5. This unit must be grounded.

This symbol shows that ENERVEX IPVB Inline Power Venters for solid fuel applications are listed under ETL File no. 514733.

ETL514733

Содержание IPVB 300

Страница 1: ...rkway Alpharetta GA 30004 USA P 770 587 3238 F 770 587 4731 T 800 255 2923 info enervex com www enervex com 3002600 08 17 Installation Operating Manual ENERVEX IPVB 300 500 INLINE POWER VENTER READ AN...

Страница 2: ...ed by this manual Please refer to these component s individual manuals TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit in the manner intended by...

Страница 3: ...Horizontal Installation 9 4 ELECTRICAL INSTALLATION 4 1 General 10 4 2 Wiring Diagram IPVB 300 10 4 3 Wiring Diagram IPVB 350 500 11 4 4 Installing a Proven Draft Switch 12 4 5 Installation of Stack...

Страница 4: ...hich is mounted outside the air stream The design is a Type B Spark Resistant Construction The motor and impeller is a complete assembly drive unit that can be removed from the fan housing without rem...

Страница 5: ...All single phase fans ae shipped with a capacitor and junction box connected via conduit The capacitor is located INSIDE the junction box Please do not discard 1 4 WARRANTY ENERVEX products are warran...

Страница 6: ...Amps 5 8 2 6 1 5 5 5 2 9 7 8 4 1 Motor Output HP 0 5 1 0 2 0 3 0 kW 0 35 0 75 1 5 2 2 Max RPM 1600 1740 Duct Connection in 12 14 16 20 Nominal mm 300 350 400 500 Dimensions A in 19 3 22 4 26 4 29 5 mm...

Страница 7: ...e it discharges through a wall A drain is provided with the IPVB to be installed by the user The IPVB is for indoor and outdoor installation Unless installed adjacent to the wall it is discharging thr...

Страница 8: ...fitting as a guide drill a 1 2 hole through the housing to open the drain B 3 4 MOUNTING OF POWER VENTER The IPVB has 4 0 413 diameter mounting holes on each end of the fan Threaded rod or steel hang...

Страница 9: ...ONTAL INSTALLATION To mount the IPVB horizontally suspend the power venter with threaded rod or steel hangers It may be necessary to cross brace the fan from end to end to prevent side sway Ensure the...

Страница 10: ...ectrical metallic tubing or be otherwise suitably protected from physical damage IPVB models operate at different voltages please pay attention to the wiring details IPVB 300 operates at 1x120VAC whil...

Страница 11: ...the motor junction box The motor wiring terminals shown in Fig 9 shows default jumper positions for 3x440 480VAC operation If the application requires 3x208 230VAC operation the jumper positions must...

Страница 12: ...s and Capacities The power venter is equipped with a variable speed motor Fig 11 below shows a typical wiring diagram utilizing a Variable Frequency Drive adjusting the speed is possible If it is not...

Страница 13: ...let of the fan the rotation of the impeller should be clockwise as shown in Fig 13 Correct rotation direction is also indicated by an arrow on the motor end cover There are holes in the end cover that...

Страница 14: ...ot apply to IPVB 300 All IPVB fans run in a clockwise direction when viewed from the fanoutlet or when looking down at the motor 4 Switching any two phases between the fan and the power source VFD is...

Страница 15: ...15 below follow these steps to open the venter so it can be cleaned and inspected 1 Remove the four hex nuts holding the motor mounting plate to the housing 2 Motor and impeller assembly can be lifte...

Страница 16: ...nce in the power to the fan is reversed Swap two phases in the junction box The fan is vibrating vigorously Foreign matter is stuck in the impeller A ball bearing is damaged A balancing weight has fal...

Страница 17: ...17 3002600 08 17 Notes...

Страница 18: ...18 3002600 08 17 Notes...

Страница 19: ...19 3002600 08 17 Notes...

Страница 20: ...ENERVEX Inc 1685 Bluegrass Lakes Parkway Alpharetta GA 30004 USA P 770 587 3238 F 770 587 4731 T 800 255 2923 info enervex com www enervex com 3002600 08 17...

Отзывы: