Enertech Bentone B 30A CN Скачать руководство пользователя страница 10

NOZZLE TABLE

Pump pressure bar

171 505 44  00-01

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

BURNER WITH PREHEATER

Consider that on preheating the oil quantity is reduced by 5-20% depending on.
-

Rise in temperature at the nozzle

-

Design of nozzle

-

Capacity (high capacity - small difference)

Gph

8

9

10

11

12

13

14

15

kg/h

kW Mcal/h

kg/h

kW Mcal/h

kg/h

kW Mcal/h

kg/h

kW Mcal/h

kg/h

kW Mcal/h

kg/h

kW Mcal/h kg/h

kW Mcal/h

kg/h

kW Mcal/h

0,40 1,33

16

13

1,41

17

14

1,49

18

15

1,56

18

16

1,63

19

17

1,70

20

17

1,76

21

18

1,82

21

18

0,50 1,66

20

17

1,76

21

18

1,86

22

19

1,95

23

20

2,04

24

21

2,12

25

22

2,20

26

22

2,28

27

23

0,60 2,00

24

20

2,12

25

22

2,23

26

23

2,34

28

24

2,45

29

25

2,55

30

26

2,64

31

27

2,73

32

28

0,65 2,16

26

22

2,29

27

23

2,42

29

25

2,54

30

26

2,65

31

27

2,75

33

28

2,86

34

29

2,96

35

30

0,75 2,49

29

25

2,65

31

27

2,79

33

28

2,93

35

30

3,08

36

31

3,18

38

32

3,30

39

34

3,42

40

35

0,85 2,83

33

29

3,00

36

31

3,16

37

32

3,32

39

34

3,47

41

35

3,61

43

37

3,74

44

38

3,87

46

39

1,00 3,33

39

34

3,53

42

36

3,72

44

38

3,90

46

40

4,08

48

42

4,24

50

43

4,40

52

45

4,56

54

46

1,10 3,66

43

37

3,88

46

39

4,09

48

42

4,29

51

44

4,48

53

46

4,67

55

48

4,84

57

49

5,01

59

51

1,20 3,99

47

41

4,24

50

43

4,47

53

46

4,68

55

48

4,89

58

50

5,09

60

52

5,29

63

54

5,47

65

56

1,25 4,16

49

42

4,40

52

45

4,65

55

47

4,88

58

50

5,10

60

52

5,30

63

54

5,51

65

56

5,70

68

58

1,35 4,49

53

46

4,76

56

48

5,02

59

51

5,27

62

54

5,50

65

56

5,73

68

58

5,95

70

61

6,15

73

63

1,50 4,98

59

51

5,29

63

54

5,58

66

57

5,85

69

60

6,11

72

62

6,36

75

65

6,60

78

67

6,83

81

70

1,65 5,49

65

56

5,82

69

59

6,14

73

63

6,44

76

66

6,73

80

69

7,00

83

71

7,27

86

74

7,52

89

77

1,75 5,82

69

59

6,18

73

63

6,51

77

66

6,83

81

70

7,14

85

73

7,42

88

76

7,71

91

79

7,97

94

81

2,00 6,65

79

68

7,06

84

72

7,45

88

76

7,81

93

80

8,18

97

83

8,49

101

86

8,81

104

90

9,12

108

93

2,25 7,49

89

76

7,94

94

81

8,38

99

85

8,78

104

89

9,18

109

94

9,55

113

97

9,91

117

101

10,26 122

105

2,50 8,32

99

85

8,82

105

90

9,31

110

95

9,76

116

99

10,19 121

104

10,61 126

108

11,01 130

112

11,39 135

116

2,75 9,15

108

93

9,71

115

99

10,24 121

104

10,73

127

109

11,21 133

114

11,67 138

119

12,11 144

123

12,53 148

128

3,00 9,98

118

102

10,59 126

108

11,16 132

114

11,71

139

119

12,23 145

125

12,73 151

130

13,21 157

135

13,67 162

139

3,50 11,65

138

119

12,35 146

126

13,03 154

133

13,66

162

139

14,27 169

145

14,85 176

151

15,42 183

157

15,95 189

163

4,00 13,31

158

136

14,12 167

144

14,89 176

152

15,62

185

159

16,31 193

166

16,97 201

173

17,62 209

180

18,23 216

186

4,50 14,97

177

153

15,88 188

162

16,75 198

171

17,57

208

179

18,35 217

187

19,10 226

195

19,82 235

202

20,51 243

209

5,00 16,64

197

170

17,65 209

180

18,62 221

190

19,52

231

199

20,39 242

208

21,22 251

216

22,03 261

225

22,79 270

232

5,50 18,30

217

187

19,42 230

198

20,48 243

209

21,47

255

219

22,43 266

229

23,34 277

238

24,23 287

247

25,07 297

256

6,00 19,97

237

204

21,18 251

216

22,34 265

228

23,42

278

239

24,47 290

249

25,46 302

260

26,43 313

269

27,49 326

280

6,50 21,63

256

220

22,94 272

234

24,20 287

247

25,37

301

259

26,51 314

270

27,58 327

281

28,63 339

292

29,63 351

302

7,00 23,29

276

237

24,71 293

252

26,06 309

266

27,33

324

279

28,55 338

291

29,70 352

303

30,84 366

314

31,91 378

325

7,50 24,96

296

254

26,47 314

270

27,92 331

285

29,28

347

298

30,59 363

312

31,83 377

324

33,04 392

337

34,19 405

349

8,00 26,62

316

271

28,24 335

288

29,79 353

304

31,23

370

318

32,63 387

333

33,95 403

346

35,25 418

359

36,47 432

372

8,50 28,28

335

288

30,00 356

306

31,65 375

323

33,18

393

338

34,66 411

353

36,07 428

368

37,45 444

382

38,74 459

395

9,00 29,95

355

305

31,77 377

324

33,59 398

342

35,14

417

358

36,71 435

374

38,19 453

389

39,65 470

404

41,02 486

418

Содержание Bentone B 30A CN

Страница 1: ...Providing sustainable energy solutions worldwide 178 024 51 Installation and maintenance instruction B 30A CN...

Страница 2: ......

Страница 3: ...ionelectrodes 4 Nozzle assembly 5 Ignitioncable 6 Ignitiontransformer 7 Controlbox 8 Reset button 9 Cover inspectionglass 10 Fanwheel 11 Motor 12 Photo cell 13 Nozzle assembly adjustment 14 Blast tube...

Страница 4: ...MENSIONS OUTPUTRANGEANDNOZZLESRECOMMENDED RECOMMENDEDNOZZLE Because of different boiler types existing on the market with varying combustionchamberdesigns itisnot possibletostateadefinitesprayangle or...

Страница 5: ...ncrease the nozzle assembly adjustment somewhat The CO2 con tent and consequently the air volume will then be reduced CONDENSATIONINCHIMNEY A modern burner works with less ex cess air and often also w...

Страница 6: ...r at the main switch and cut off the oil supply Open the cover and disconnect the connecting pipes by loosening screw A SERVICE OF BURNER HEAD 171 305 74 95 01 1 Loosen or swing out the burner from th...

Страница 7: ...ordance with point 1 are fulfilled The oil burner control cuts out A red lamp in the control is lit Press the reset button and the burner re starts Post ignition 2 If a post ignition of 15 s is wanted...

Страница 8: ...suction line tables consist of theoretically calculated values where the pipe dimensions and oil velocity havebeenmatchedsothatturbulences will not occur Such turbulences will resultinincreasedpressu...

Страница 9: ...nto startingposition This can be remedied by Reducing the pump pressure Reducing the oil quantity supplied by using a smaller nozzle Usingapumpwithalargercapacity Thediaphragmandthespringkeep the pump...

Страница 10: ...79 7 97 94 81 2 00 6 65 79 68 7 06 84 72 7 45 88 76 7 81 93 80 8 18 97 83 8 49 101 86 8 81 104 90 9 12 108 93 2 25 7 49 89 76 7 94 94 81 8 38 99 85 8 78 104 89 9 18 109 94 9 55 113 97 9 91 117 101 10...

Страница 11: ...as not reset Appliance overheat device has operated Control relay or photocell defective Adjust thermostat Check by replacement Motor runs Burner runs to lockout No oil being delivered Excessive flue...

Страница 12: ...nt conformes aux normes et aux documents normatifs suivants et satisfont aux crit res applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suivan...

Страница 13: ...the burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...

Страница 14: ......

Страница 15: ......

Страница 16: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...

Отзывы: