background image

Overview Guide

Contents:

Installation…………………………...….. 1-2
LED Indicators….……………….....…… 3-5
Home Screens……..……….…..……....

  

5-7

Soft Keys……….……………..…..…….. 7-15
Hot Keys…….……………..…….…….. 16-19
Replay Function (OPTICS RE)………… 20
Specifications……..……….…..…………

 

22

IMPORTANT  

Signal degradation can result if cable is run in conduit with AC wiring or in other electrically “noisy” environments; these can affect 
the maximum length the cable can run without incurring transmission errors.

CAUTION:  EQUIPMENT DAMAGE  

The MATE3s is intended for indoor installations only. 

NOTES



The MATE3s voltage is less than 30 Vdc and is thus considered a “limited energy” circuit normally requiring no conduit.



CAT5 cable is not as strong as house wiring and must be handled carefully.  Avoid kinking the cable or tearing its outer sheathing.



Use plastic standoff cable staples, J-hooks, or cable trays to support long runs of CAT5 cable. 

Do not splice cables.

IMPORTANT:  

Not intended for use with 

life support equipment.

7 1/8" 

(17.9 cm)

2 3/8" 

(6.0 cm)

7 ¼” (18.4 cm)

6 5/8" (16.8 cm)

5/16" (0.79 cm)

9/16" 

(1.4 cm)

1 5/8" (4.2 cm)

7 1/2” (19 cm)

!

F

F

E

F

A

B

C

D

G

F

F

F

F

F

D

H

Features

A

:  LCD display screen

E

:  Navigation keys

B

:  Soft keys

F

:  Mounting Holes

C

:  Hot keys

G

:  Ethernet port

D

:  SD card slot

H

:  HUB Communications Manager port

NOTE

:  This document assumes knowledge of features, functions, and operation 

of other OutBack products.  Consult appropriate literature as necessary.

Items 

1

2

, and 

3

 are the MATE3s 

mounting options from OutBack.

Item 

is a semi-transparent front view which 

also shows the ports and other back features.

To mount the MATE3s on the wall 

without the accessory brackets:

1. Cut a hole in the surface at the location and

    size shown in 

4

.  This allows room for the

    CAT5 cables to protrude through the wall.
2. Place the MATE3s on the wall with the cables

    inside the hole.  Mark the mounting holes (

F

)

    by pushing a long nail into the mounting holes

    and putting a leader hole in the wall surface. 

    

NOTE

:

  Do not use a nail that is larger than

    the mounting screws.

    

 " 

(4.1 cm)

2" 

(5.1 cm)

1 ½" 

(3.8 cm)

1

 " (3.5 

cm)

F

F

F

F

1

2

3

4

Contact Information

About OutBack Power 

OutBack Power is a leader in advanced energy conversion technology.  OutBack products include true sine wave inverter/chargers, 
maximum power point tracking charge controllers, and system communication components, as well as circuit breakers, batteries, 
accessories, and assembled systems.

Contact Information 

Mailing Address:

17825 – 59th Avenue NE
Suite B
Arlington, WA 98223 USA

Web Site:

www.outbackpower.com

Disclaimer

UNLESS SPECIFICALLY AGREED TO IN WRITING, OUTBACK POWER:

(a) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER
INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.

(b) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT,  INDIRECT, CONSEQUENTIAL
OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION.  THE USE OF ANY SUCH INFORMATION
WILL BE ENTIRELY AT THE USER’S RISK.

OutBack Power cannot be responsible for system failure, damages, or injury resulting from improper installation of their products.

Notice of Copyright

MATE3s System Display and Controller Overview Guid

e © 2017 by OutBack Power.  All Rights Reserved.

Trademarks

OutBack Power, the OutBack Power logo, OPTICS RE, and Grid/Hybrid are trademarks owned and used by 
OutBack Power, an EnerSys company.  These trademarks may be registered in the United States and other countries.

Date and Revision

November

 2019, Revision B 

Part Number

900-0124-01-02 Rev B

Содержание OutBack POWER MATE3s

Страница 1: ...This allows room for the CAT5 cables to protrude through the wall 2 Place the MATE3s on the wall with the cables inside the hole Mark the mounting holes F by pushing a long nail into the mounting holes and putting a leader hole in the wall surface NOTE Do not use a nail that is larger than the mounting screws 1 4 1 cm 2 5 1 cm 1 3 8 cm 1 3 5 cm F F F F 1 2 3 4 Contact Information About OutBack Pow...

Страница 2: ...enced radio TV technician for help M AT E R T S PV PV BAT BAT MATE Port RJ45 RTS Port RJ11 In 23 2 V 0 0 A Out 27 6 V 0 0 A 0 000 kW 0 0 kWH AUX OFF Sleeping Ethernet Port 1st MATE 1 2 3 4 5 6 7 8 9 10 MATE3s Inverter Additional Stacked Inverters HUB10 3 Communications Manager The MATE3s connects to other OutBack products using the HUB port To learn what configurations are available see the approp...

Страница 3: ...s It will proceed to locate and identify the attached components and the ports they occupy on the HUB It will then stop on the Home screen RED 11 4 Vdc or lower 22 8 Vdc or lower 34 2 Vdc or lower 45 6 Vdc or higher Low YELLOW 11 5 to 12 4 Vdc 23 0 to 24 8 Vdc 34 5 to 37 2 Vdc 46 0 to 49 6 Vdc Usable GREEN 12 5 Vdc or higher 25 0 Vdc or higher 37 5 Vdc or higher 50 0 Vdc or higher Acceptable 24 Vd...

Страница 4: ...rator Status menu The generator is determined to be running based on input AC voltage if the generator type is AC This LED will usually illuminate in conjunction with the AC INPUT LED indicator It only illuminates when an AC generator is used OFF The Generator Status menu has been set to OFF or the AGS function has not been enabled If the generator shuts down or stops delivering power this indicat...

Страница 5: ...e parameters for the bars are based on the data in System Information o The meter bar represents the charge controller output If no charge controller is detected this bar is not present In the FM100 AFCI the symbol also appears if the controller shuts down due to any of several faults See page 7 o The left meter bar represents inverter output when System Type is set to Off Grid or Backup o The rig...

Страница 6: ...plays a screen with the reason for the last AC disconnect Screen Items O This screen shows the reason for the inverter s last automatic disconnection from the AC source The possible reasons include Input Frequency Too High Input Frequency Too Low Input Voltage Maximum or Input Voltage Minimum Radian class and FXR class inverters have Backfeed Phase Lock or Island Detect Most items show N no If an ...

Страница 7: ...tion available depends on whether the FLEXnet DC battery monitor is installed See page 12 The Inverter soft key Q displays information on any inverters present on the HUB If no inverters are present Q is inoperative The symbol is not present See page 8 For FX class inverters In the Off Grid system type R is Input Select It may not have a symbol The symbol only appears if a generator is running See...

Страница 8: ... of operation Sell Charging or other modes In RMS the power factor and input current of the AC source Invert shown in A or Charge shown in B Invert displays the kilowatts and AC current produced for loads offsetting or when grid interactive sold back to the utility grid Charge displays the kilowatts and AC current used to charge the battery bank This line also shows the charge mode Load the kilowa...

Страница 9: ... A3 brings up AC input data If the inverter is not in the Grid Tied AC input mode or connected to the utility grid not all items will function Screen Items A3 Grid the present AC voltage from the source the utility grid Min and Max the lowest and highest daily AC voltage and the time each was recorded Mode the inverter s present operating status either buying or selling and the number of kilowatts...

Страница 10: ...r Battery screen Screen Items F Actual The battery voltage This item is not compensated for temperature See below Absorb and Float The inverter s primary charger settings for the three main battery charging stages Equalize The inverter s Equalization voltage setting It is used during the battery equalization cycle Temp Comp The battery voltage after compensation from the Remote Temperature Sensor ...

Страница 11: ...aily PV current and wattage and the recorded times The lower right corner shows the current status of the controller s Auxiliary AUX output See the MATE3s Programming Guide and the charge controller manual G E B F H M M Bullet styles from PRG Page P 14 Soft Keys Charge Controller 900 0124 01 02 Rev B 2017 OutBack Power All Rights Reserved Page 11 Soft Keys Inverter o The Error soft key H displays ...

Страница 12: ...attery monitor is installed the Battery soft key A opens screen A1 o If the FLEXnet DC FN DC battery monitor is not present the Battery soft key A opens screen A2 Screen Items A2 Bat The measured battery voltage This reading is not compensated for temperature Min and Max The lowest and highest recorded voltages that day These lines also show the time the voltages were recorded o From the Battery S...