 Page 6

Home Screen Legend

900-0124-01-02 Rev B

©2017 OutBack Power.  All Rights Reserved.

 Page 19

O

C

The 

AC INPUT

 hot key (

C

) brings up 

AC Input Status

, with information on the 

AC source.  It also has commands that can connect or disconnect from the source. 

AC INPUT

Screen Items

 (

C

):



AC Input Select

 (

Radian-class only):  This displays which of two inputs was set as first

priority for the inverter.  (See the 

MATE3s Programming Guide

 to make this selection.)

This item is not present in FX-class or FXR-class inverters.



The top line also displays the present AC voltage and frequency from the input source.



Input Mode

:  

Allows soft key options to change the mode.  This may be overridden by other commands.  For example, a system set

to 

Drop 

will automatically switch to 

Use 

if AGS starts the generator.



Next to 

AC Input Select

 

is the last reason the status was changed.  In 

C

, the change is due to an 

HBX-SOC

 event.  Other possible

reasons are 

Manual

AGS

Grid-Time

,

 Load Grid

or 

HBX-Voltage

.  See the 

MATE3s Programming Guide

 for more information.



AC Input Status

:

 This displays the current interaction with the AC input.  This screen will usually change to match 

AC Input Mode

once a soft key command is given.  In Radian-class inverters, the displayed AC voltage is the sum of the L1 and L2 phases.



The 

<

Drop

>

 and 

<

Use

>

 soft keys (

M

 and 

N

) manually disconnect or connect to the AC source.



The 

<

Discon

>

 soft key (

O

) displays a screen with the reason for the last AC disconnect.

Screen Items 

(

O

):

This screen shows the reason for the inverter’s last automatic disconnection 
from the AC source.  The possible reasons include 

Input Frequency Too 

High

Input Frequency Too Low

Input Voltage > Maximum

, or 

Input 

Voltage < Minimum

.  Radian-class and FXR-class inverters have 

Backfeed

Phase Lock

, or 

Island Detect

.  Most items show 

(no).  If an item shows 

Y

 (yes), the inverter disconnected for that reason.  

FAVORITE

The 

FAVORITE 

hot key (

D

) allows the user 

to program and select up to four frequently 
used (or “favorite”) screens for rapid access.  
It includes a green LED indicator.

To program the 

FAVORITE 

hot key:

1. Navigate to the desired screen.
2. Press and hold the 

FAVORITE 

hot key until the

green indicator flashes.
3. Press one of the four programmable soft keys to
select it for recalling that particular screen.  The
green 

FAVORITE 

LED indicator will stop flashing.

4. Repeat Steps 1-3 to program three more favorite
screens (if desired).

To use the 

FAVORITE 

hot key to recall the desired screen(s):

1. Press and release the 

FAVORITE 

hot key.  The green 

FAVORITE 

indicator will

illuminate and stay on.
2. Press the soft key for the desired screen to be recalled.
If no selection is made after pressing the 

FAVORITE 

hot key, the function will 

deactivate and the green indicator will turn off.

N

M

O

Hot Keys:  

AC INPUT & FAVORITE

IMPORTANT  

Only one favorite screen 
can be programmed per soft 
key.  Attempting to program 
more than one screen to the 
same soft key will overwrite 
the first screen.
Password-protected 
screens cannot be saved as 
favorites.  This means that 
the screens described in the 

MATE3s Programming 
Guide

 cannot be saved this 

way.  (These include any 
screens accessed with the 

LOCK 

key.)

Содержание OutBack POWER MATE3s

Страница 1: ...This allows room for the CAT5 cables to protrude through the wall 2 Place the MATE3s on the wall with the cables inside the hole Mark the mounting holes F by pushing a long nail into the mounting holes and putting a leader hole in the wall surface NOTE Do not use a nail that is larger than the mounting screws 1 4 1 cm 2 5 1 cm 1 3 8 cm 1 3 5 cm F F F F 1 2 3 4 Contact Information About OutBack Pow...

Страница 2: ...enced radio TV technician for help M AT E R T S PV PV BAT BAT MATE Port RJ45 RTS Port RJ11 In 23 2 V 0 0 A Out 27 6 V 0 0 A 0 000 kW 0 0 kWH AUX OFF Sleeping Ethernet Port 1st MATE 1 2 3 4 5 6 7 8 9 10 MATE3s Inverter Additional Stacked Inverters HUB10 3 Communications Manager The MATE3s connects to other OutBack products using the HUB port To learn what configurations are available see the approp...

Страница 3: ...s It will proceed to locate and identify the attached components and the ports they occupy on the HUB It will then stop on the Home screen RED 11 4 Vdc or lower 22 8 Vdc or lower 34 2 Vdc or lower 45 6 Vdc or higher Low YELLOW 11 5 to 12 4 Vdc 23 0 to 24 8 Vdc 34 5 to 37 2 Vdc 46 0 to 49 6 Vdc Usable GREEN 12 5 Vdc or higher 25 0 Vdc or higher 37 5 Vdc or higher 50 0 Vdc or higher Acceptable 24 Vd...

Страница 4: ...rator Status menu The generator is determined to be running based on input AC voltage if the generator type is AC This LED will usually illuminate in conjunction with the AC INPUT LED indicator It only illuminates when an AC generator is used OFF The Generator Status menu has been set to OFF or the AGS function has not been enabled If the generator shuts down or stops delivering power this indicat...

Страница 5: ...e parameters for the bars are based on the data in System Information o The meter bar represents the charge controller output If no charge controller is detected this bar is not present In the FM100 AFCI the symbol also appears if the controller shuts down due to any of several faults See page 7 o The left meter bar represents inverter output when System Type is set to Off Grid or Backup o The rig...

Страница 6: ...plays a screen with the reason for the last AC disconnect Screen Items O This screen shows the reason for the inverter s last automatic disconnection from the AC source The possible reasons include Input Frequency Too High Input Frequency Too Low Input Voltage Maximum or Input Voltage Minimum Radian class and FXR class inverters have Backfeed Phase Lock or Island Detect Most items show N no If an ...

Страница 7: ...tion available depends on whether the FLEXnet DC battery monitor is installed See page 12 The Inverter soft key Q displays information on any inverters present on the HUB If no inverters are present Q is inoperative The symbol is not present See page 8 For FX class inverters In the Off Grid system type R is Input Select It may not have a symbol The symbol only appears if a generator is running See...

Страница 8: ... of operation Sell Charging or other modes In RMS the power factor and input current of the AC source Invert shown in A or Charge shown in B Invert displays the kilowatts and AC current produced for loads offsetting or when grid interactive sold back to the utility grid Charge displays the kilowatts and AC current used to charge the battery bank This line also shows the charge mode Load the kilowa...

Страница 9: ... A3 brings up AC input data If the inverter is not in the Grid Tied AC input mode or connected to the utility grid not all items will function Screen Items A3 Grid the present AC voltage from the source the utility grid Min and Max the lowest and highest daily AC voltage and the time each was recorded Mode the inverter s present operating status either buying or selling and the number of kilowatts...

Страница 10: ...r Battery screen Screen Items F Actual The battery voltage This item is not compensated for temperature See below Absorb and Float The inverter s primary charger settings for the three main battery charging stages Equalize The inverter s Equalization voltage setting It is used during the battery equalization cycle Temp Comp The battery voltage after compensation from the Remote Temperature Sensor ...

Страница 11: ...aily PV current and wattage and the recorded times The lower right corner shows the current status of the controller s Auxiliary AUX output See the MATE3s Programming Guide and the charge controller manual G E B F H M M Bullet styles from PRG Page P 14 Soft Keys Charge Controller 900 0124 01 02 Rev B 2017 OutBack Power All Rights Reserved Page 11 Soft Keys Inverter o The Error soft key H displays ...

Страница 12: ...attery monitor is installed the Battery soft key A opens screen A1 o If the FLEXnet DC FN DC battery monitor is not present the Battery soft key A opens screen A2 Screen Items A2 Bat The measured battery voltage This reading is not compensated for temperature Min and Max The lowest and highest recorded voltages that day These lines also show the time the voltages were recorded o From the Battery S...

Отзывы: