background image

 Page 23

FCC

FCC Information to the User

This equipment has been tested and found to comply with the limits for a Class B digital device when 
powered by a DC source, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This equipment 
generates uses and can radiate radio frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures: 

o

Reorient or relocate the receiving antenna.

o

Increase the separation between the equipment and the receiver.

o

Consult the dealer or an experienced radio/TV technician for help.

M

AT

E

R
T
S

PV 

+

PV 

BAT

BAT 

+

MATE 

Port 

(RJ45)

RTS 
Port 

(RJ11)

In   23.2 V     0.0 A
Out  27.6 V     0.0 A
    0.000 kW    0.0 kWH
AUX:  OFF     Sleeping

Ethernet 

Port

1

st

 

MATE

1

2

3

4

5

6

7

8

9

10

MATE3s

Inverter 

Additional (Stacked) Inverters

HUB10.3 

Communications Manager

The MATE3s connects to other OutBack products using  

the HUB port.  To learn what configurations are available, 

see the appropriate manual.  To make MATE3s settings 

for a configuration, see the 

MATE3s Programming Guide

.

FLEXmax 

Charge 

Controller 

(FM80)

M

AT

E

R
T
S

MATE3s

Inverter

PV 

+

PV 

BAT

BAT 

+

MATE 

Port 

(RJ45)

RTS 
Port 

(RJ11)

MATE3s

FLEXmax 

Charge Controller 

(FM80)

Product 

Configurations 

(examples)

Communications Interfacing 

(examples)

Wireless Router

Wireless 

Access Point

Wired

Cellular 

Modem

HUB 

Port

The MATE3s interfaces with other devices using a wired connection to the 

Ethernet port.  The connections here are used for Internet access with the 

OPTICS RE interface.  Other connections are possible.  The MATE3s can 

connect using a network switch or a wireless network router.

NOTE

:  

All communications use 

CAT5 (non-crossover) cable.

 Page 2

Communications

900-0124-

01-

02 Rev B

©2017 OutBack Power.  All Rights Reserved.

LED Indicators

Содержание OutBack POWER MATE3s

Страница 1: ...This allows room for the CAT5 cables to protrude through the wall 2 Place the MATE3s on the wall with the cables inside the hole Mark the mounting holes F by pushing a long nail into the mounting holes and putting a leader hole in the wall surface NOTE Do not use a nail that is larger than the mounting screws 1 4 1 cm 2 5 1 cm 1 3 8 cm 1 3 5 cm F F F F 1 2 3 4 Contact Information About OutBack Pow...

Страница 2: ...enced radio TV technician for help M AT E R T S PV PV BAT BAT MATE Port RJ45 RTS Port RJ11 In 23 2 V 0 0 A Out 27 6 V 0 0 A 0 000 kW 0 0 kWH AUX OFF Sleeping Ethernet Port 1st MATE 1 2 3 4 5 6 7 8 9 10 MATE3s Inverter Additional Stacked Inverters HUB10 3 Communications Manager The MATE3s connects to other OutBack products using the HUB port To learn what configurations are available see the approp...

Страница 3: ...s It will proceed to locate and identify the attached components and the ports they occupy on the HUB It will then stop on the Home screen RED 11 4 Vdc or lower 22 8 Vdc or lower 34 2 Vdc or lower 45 6 Vdc or higher Low YELLOW 11 5 to 12 4 Vdc 23 0 to 24 8 Vdc 34 5 to 37 2 Vdc 46 0 to 49 6 Vdc Usable GREEN 12 5 Vdc or higher 25 0 Vdc or higher 37 5 Vdc or higher 50 0 Vdc or higher Acceptable 24 Vd...

Страница 4: ...rator Status menu The generator is determined to be running based on input AC voltage if the generator type is AC This LED will usually illuminate in conjunction with the AC INPUT LED indicator It only illuminates when an AC generator is used OFF The Generator Status menu has been set to OFF or the AGS function has not been enabled If the generator shuts down or stops delivering power this indicat...

Страница 5: ...e parameters for the bars are based on the data in System Information o The meter bar represents the charge controller output If no charge controller is detected this bar is not present In the FM100 AFCI the symbol also appears if the controller shuts down due to any of several faults See page 7 o The left meter bar represents inverter output when System Type is set to Off Grid or Backup o The rig...

Страница 6: ...plays a screen with the reason for the last AC disconnect Screen Items O This screen shows the reason for the inverter s last automatic disconnection from the AC source The possible reasons include Input Frequency Too High Input Frequency Too Low Input Voltage Maximum or Input Voltage Minimum Radian class and FXR class inverters have Backfeed Phase Lock or Island Detect Most items show N no If an ...

Страница 7: ...tion available depends on whether the FLEXnet DC battery monitor is installed See page 12 The Inverter soft key Q displays information on any inverters present on the HUB If no inverters are present Q is inoperative The symbol is not present See page 8 For FX class inverters In the Off Grid system type R is Input Select It may not have a symbol The symbol only appears if a generator is running See...

Страница 8: ... of operation Sell Charging or other modes In RMS the power factor and input current of the AC source Invert shown in A or Charge shown in B Invert displays the kilowatts and AC current produced for loads offsetting or when grid interactive sold back to the utility grid Charge displays the kilowatts and AC current used to charge the battery bank This line also shows the charge mode Load the kilowa...

Страница 9: ... A3 brings up AC input data If the inverter is not in the Grid Tied AC input mode or connected to the utility grid not all items will function Screen Items A3 Grid the present AC voltage from the source the utility grid Min and Max the lowest and highest daily AC voltage and the time each was recorded Mode the inverter s present operating status either buying or selling and the number of kilowatts...

Страница 10: ...r Battery screen Screen Items F Actual The battery voltage This item is not compensated for temperature See below Absorb and Float The inverter s primary charger settings for the three main battery charging stages Equalize The inverter s Equalization voltage setting It is used during the battery equalization cycle Temp Comp The battery voltage after compensation from the Remote Temperature Sensor ...

Страница 11: ...aily PV current and wattage and the recorded times The lower right corner shows the current status of the controller s Auxiliary AUX output See the MATE3s Programming Guide and the charge controller manual G E B F H M M Bullet styles from PRG Page P 14 Soft Keys Charge Controller 900 0124 01 02 Rev B 2017 OutBack Power All Rights Reserved Page 11 Soft Keys Inverter o The Error soft key H displays ...

Страница 12: ...attery monitor is installed the Battery soft key A opens screen A1 o If the FLEXnet DC FN DC battery monitor is not present the Battery soft key A opens screen A2 Screen Items A2 Bat The measured battery voltage This reading is not compensated for temperature Min and Max The lowest and highest recorded voltages that day These lines also show the time the voltages were recorded o From the Battery S...

Отзывы: