background image

0170022-J0 Rev A

Page 13

4.3

Dry Contact Description

Contacts C1 to C5 allow the unit to be connected to an external monitoring panel or to traffic control 

equipment.

Figure 3:

Dry Contact Overview

Output Terminal Block

The unit’s AC power output.

USB-A input

The USB input connector connects USB memory stick for system 

backup, restore and download of logs and configuration files.

Table 5:

Feature Description (Continued) (Sheet 2 of 2)

Feature

Description

Table 6:

C1 to C5 Dry Contacts  (Sheet 1 of 2)

Feature

Description

C1 (On Battery)

The C1 contact is energized when line power is unqualified and the 

unit provides backup battery power to the load(s). It can be used to 

generate an 

On Battery

 contact.

C2, C3 (Low B No 

Line_LOBAT NOLIN)

These contacts are energized when the battery drops below a pre-set 

voltage level and line is not present. They can be used to generate a 

Low Battery

 alarm. To change the pre-programmed level to match the 

batteries used and the actual operating conditions, see 

Low Battery 

Warning

 in "UPS Maintenance > Battery”.

C4 (Timer)

This contact is energized after the unit has been in Inverter mode for 

two hours. To change the pre-programmed two hours to match your 

operating conditions, see 

Load Shedding Relays

.

C5 (Alarm)

The C5 contact is energized when any alarm is generated.

The contacts have a 
maximum rating of 
1A at 240V.

Microprocessor

UPS
Interior

Normally
Closed (NC)

Normally
Open (NO)

Common(C)

Содержание Alpha FXM HP 1100

Страница 1: ...Alpha FXM HP 650 1100 2000 UPS Technical Guide 0170022 J0 Effective 11 2019...

Страница 2: ......

Страница 3: ...red trademark of Alpha Technologies No part of this documentation shall be reproduced stored in a retrieval system translated transcribed or transmitted in any form or by any means manual electric ele...

Страница 4: ......

Страница 5: ...Transition 8 4 FEATURES 11 Front Panel 11 Feature Description 12 Dry Contact Description 13 5 INSPECTION 17 Check for Damage 17 Packing Materials 17 Returns for Service 17 6 INSTALLATION 19 Installati...

Страница 6: ...mpensation 64 Battery Test 65 Battery Runtime and Health Estimation 66 AC Output 67 Inverter Control 67 Load Shedding Relays 68 External Fan 69 Keep Alive 69 Creating a FXM HP System Manually 71 Quick...

Страница 7: ...ng the Controller Battery 104 Working with Logs 105 Event and Alert Logs 105 Battery Log 106 Power Outage Log 107 Datalogs 107 Performance Logs 111 File Maintenance 111 File Preferences 112 File Maint...

Страница 8: ...129 11 APPENDIX A TRIGGERS 131 12 WARRANTY AND SERVICE INFORMATION 133 Technical Support 133 Warranty Statement 133 Product Warranty 133 Battery Warranty 133 Warranty Claims 133 Service Information 1...

Страница 9: ...Controller Status 37 Figure 14 Time and Date 37 Figure 15 Timezone 38 Figure 16 Network Time Server 38 Figure 17 Synchronize Time 39 Figure 18 System Shortcuts 39 Figure 19 Status 40 Figure 20 AC Inp...

Страница 10: ...ion 1 More Information Page 60 Figure 53 System Mode 62 Figure 54 Three Stage Charging Cycle 64 Figure 55 Temperature Compensation Voltage Graph 65 Figure 56 Quick Reference for Configuring a FXM Syst...

Страница 11: ...6 C1 to C5 Dry Contacts 13 Table 7 C7 to C8 Optically Isolated User Inputs 14 Table 8 FXM HP Part Numbers 19 Table 9 Email Notification Features 57 Table 10 Email Configuration 58 Table 11 FXM HP Oper...

Страница 12: ...viii...

Страница 13: ...PREVENT BURNS to the technician or user 1 2 General Warning and Cautions WARNING You must read and understand the following warnings before installing the system and its components Failure to do so co...

Страница 14: ...t 1 4 Battery Safety Never transport an enclosure with batteries installed Batteries must ONLY be installed after the enclosure has been securely set in place at its permanent installation location Tr...

Страница 15: ...tes ticket dispensers VMS signs and AC Small Cell power backup Some of the benefits of BBS are Providing continual power to your operating system in the event of a power outage sag or brown out until...

Страница 16: ...or low voltage systems Features include Eight digital inputs Four voltage sensors Four temperature sensors Four current sensors 12 Form C relay outputs 2 2 4 Alpha Cordex HP Digital Controller The FXM...

Страница 17: ...22 Nominal Frequency Hz 50Hz or 60Hz Autodetect Frequency is the default configuration can also be manually configured Frequency Tolerance in Line Mode 5 MaximumInput Current A 1 8 4 4 10 5 15 8 20 12...

Страница 18: ...l Dimensions H x W x D mm in 89 x 432 x 229 3 47 x 17 x 9 133 x 394 x 222 5 22 x 15 5 x 8 75 Weight without batteries kg lb 11 3 25 14 31 18 40 Mounting Shelf rack or wall horizontal or vertical mount...

Страница 19: ...to 45 C 210V 40 to 50 C 40 to 55 C Humidity Up to 95 non condensing Altitude m ft 5 3700 12 000 Audible Noise6 45dBa 1 meter BTU Hr Inverter Mode 700 845 375 640 675 1235 1185 Connections AC input an...

Страница 20: ...0ft 6 Measured at 25 C ambient temperature Table 1 Specifications FXM HP 650 1100 2000 Continued Sheet 4 of 4 FXM HP 650 24 120Vac FXM HP 650 24 230Vac FXM HP 650 48 120Vac FXM HP 1100 120Vac FXM HP 1...

Страница 21: ...2 9 162 8 163 Buck 2 to Buck 1 145 5 145 4 145 6 Buck 1 to Line 127 1 126 9 126 4 Line to Boost 1 110 4 110 4 110 4 Boost 1 to Boost 2 96 1 96 96 4 Boost 2 to Inverter 84 5 84 4 84 8 Table 4 AVR Trans...

Страница 22: ...2 239 238 6 Line to Boost 1 207 3 207 206 9 Boost 1 to Boost 2 174 5 174 4 173 9 Boost 2 to Inverter 153 6 153 6 153 1 Table 4 AVR Transition FXM HP 650 1100 2000 230V Continued Sheet 2 of 2 AVR Trans...

Страница 23: ...n Home button Battery breaker Battery temp sensor connector Contacts C7 to C8 Contacts C1 to C6 LCD control panel USB A USB mini B Ethernet 1 Ethernet 2 Battery voltage test points ON OFF Battery conn...

Страница 24: ...These test points accept 2mm diameter test probe tips The battery circuit breaker must be on to measure the battery voltage NOTE The battery voltage test points are not to be used as a power port CAN...

Страница 25: ...s backup battery power to the load s It can be used to generate an On Battery contact C2 C3 Low Battery No Line_LOBAT NOLIN These contacts are energized when the battery drops below a pre set voltage...

Страница 26: ...lt for C6 Table 7 C7 to C8 Optically Isolated User Inputs Sheet 1 of 2 Feature Description User Input C7 This relay has three contacts that are used to control the unit 19 S1 Shorting this contact sta...

Страница 27: ...external batteries to this dry contact If the optional Alpha Off Line Automatic Transfer Switch ATS is connected it will cause the ATS to switch the load from line power to battery backup power Figur...

Страница 28: ...0170022 J0 Rev A Page 16...

Страница 29: ...irements As such Alpha strives to follow our quality and environmental objectives from product supply and development through to the packaging for our products Rectifiers UPSs and batteries are shippe...

Страница 30: ...0170022 J0 Rev A Page 18...

Страница 31: ...ation Insulated tools are recommended Use this list as a guide AC DC voltmeter Labels or masking tape and marker Torque wrench for input output terminal blocks Slot head screwdriver to fit the termina...

Страница 32: ...icted to authorized personnel then the covers and bracket may not be needed FXM HP650 48 120V 0170023 101 FXM HP1100 120V 0170024 001 FXM HP1100 230V 0170024 101 FXM HP2000 120V 0170022 001 FXM HP2000...

Страница 33: ...t points on the FXM HP as well as the rack and mounting brackets and bring them to a bright finish 2 Coat the attachment points with an anti oxidant such as Sanchem Inc No Ox ID A Special Elec trical...

Страница 34: ...d the power connection panel can be rotated to suit your needs To rotate the control panel 1 Remove the four screws holding the control panel to the FXM HP 2 Gently pull the control panel sub assembly...

Страница 35: ...ote that the control panel can only be rotated clockwise 90 4 Carefully reinstall the control panel Smooth out the wires and cables so they do not get caught or pinched Replace the four screws 5 Follo...

Страница 36: ...fan on the FXM HP 1100 2000 shown 1 Shut down the unit 2 Remove the four screws connecting the fan plate to the unit 3 Pull the fan plate assembly out and disconnect the fan connector 4 Remove the fou...

Страница 37: ...ies Refer to the safety section in this manual Use new batteries when installing a new unit Verify that all batteries are the same type with iden tical date codes For the FXM HP 650 24 the battery str...

Страница 38: ...reaker if OFF 7 Connect the external batteries to the battery connector on the front panel of the FXM HP 8 Route the sensor end of the battery temperature sensor to the batteries 9 Attach the battery...

Страница 39: ...and C8 2 Connect the load to the Alpha FXM HP output terminal block Torque to 1 4 N m 12 lb in 3 Connect the line power to the Alpha FXM HP input terminal block Torque to 1 4 N m 12 lb in 4 If needed...

Страница 40: ...irectly connected to the line or generator power without any conditioning Depending on the use of one and or the other the UATS UGTS allows the use of up to three different back up sources line batter...

Страница 41: ...qualified To provide backup battery power to the load run the Start Up command on the LCD s System Shortcut Status screen The Alpha FXM HP by default is configured for auto frequency detection When t...

Страница 42: ...wn automatically If it is not necessary to operate the Alpha FXM HP in the Inverter mode switch the Alpha FXM HP back to the Line mode as soon as possible To switch the Alpha FXM HP from Inverter mode...

Страница 43: ...e dashboard provides an at a glance view of the overall system s 8 1 1 Logging in to the Controller You can login to the controller via the LCD or the web interface 1 Enter the default IP address 192...

Страница 44: ...the default User Name admin b Enter the default Password admin 4 Press the check mark to complete the login process The main dashboard displays 8 1 2 Controller Menu Map The following is an overview...

Страница 45: ...Logs Datalogs Performance Active Alarms Alarm Cut off and Global Alarm Settings All Alarm Settings Charging Temperature Comp Equalize and Boost Battery Test Battery Runtime AC Output Inverter Control...

Страница 46: ...controller when it is powered up and running normally is called the dashboard See the following figure Figure 9 FXM HP Controller Dashboard The upper left area of the dashboard is the Alarm tile If t...

Страница 47: ...ntly needed maintenance tasks including the Alarm Cut Off Pressing the Maintenance button takes you to the Maintenance screen The first page contains general shortcuts like Alarm Cut Off Forget All in...

Страница 48: ...ick the Menu button on the LCD dashboard to navigate and select menu items The menu items are as follows Controller System Modules Alarms Logs When a menu item is selected it is highlighted in blue an...

Страница 49: ...can edit settings or perform actions For example from the Controller Controller Status Configure Controller Time and Date screen click the pencil icon to set the following Current Time and Date Time Z...

Страница 50: ...e text box You can either try again or click the back arrow to abandon the change Another screen that displays when clicking items is the Execute screen For example Synchronize Time Most edits and exe...

Страница 51: ...provides quick access to often used areas of the FXM HP system To get to the Systems Shortcuts screen press anywhere on the system area of the dashboard Figure 18 System Shortcuts System Functions ava...

Страница 52: ...170022 J0 Rev A Page 40 Figure 19 Status AC Input Provides a shortcut to System Status AC Input page Figure 20 AC Input AC Output Provides a shortcut to System Status AC Output page Figure 21 AC Outpu...

Страница 53: ...ge Figure 22 Battery Battery Test Provides a shortcut to the System System Functions Battery Test page Figure 23 Battery Test Inverter Provides a shortcut to the System System Functions Inverter Contr...

Страница 54: ...e 24 Inverter Control Shutdown Provides a shortcut to the System Function AC Shutdown page Figure 25 AC Shutdown Counters Statistics Provides a shortcut to the System Status Statistics maintenance pag...

Страница 55: ...e 43 Figure 26 Counters Keep Alive Provides a shortcut to the System Functions Keep Alive page Figure 27 Keep Alive Status External Fan Provides a shortcut to the System Functions External Fan page Fi...

Страница 56: ...ts Provides a maintenance page to monitor and configure the user inputs Figure 30 User Inputs Configuration User Alarms Provides a shortcut to the Controller Advanced Functions User Alarms page This p...

Страница 57: ...0170022 J0 Rev A Page 45 Figure 31 User Alarms Relays Provides a maintenance page to monitor and configure the relays Figure 32 Relays Figure 33 Relays Status...

Страница 58: ...ration Timers Provides a maintenance page to configure the load shedding timers See Load Shedding Relays for more details Figure 35 Load Shedding Relays Event Logs Provides a record of changes to the...

Страница 59: ...s If there are active alarms the Alarm Notification tile displays the last active alarm according to alarm priority Red for major or critical alarms Amber for minor alarms Blue for warnings Clicking...

Страница 60: ...menus the interface provides a context sensitive breadcrumb trail at all levels so that you can see where you are within the system and go back to any previous menu The lower area of the main dashboa...

Страница 61: ...0170022 J0 Rev A Page 49 Figure 38 Main Dashboard Tables On each line of the table the right side displays an icon There are three different types of icons...

Страница 62: ...a particular table The search bar on the upper left side performs a search on each of the space separated terms in all columns of the table The Aa toggle can be used to make the search case sensitive...

Страница 63: ...a tiles Controller Status Configure Controller Inventory and Advanced Functions Figure 41 Controller Menu Controller Status Provides the ability to reset the controller and view critical controller re...

Страница 64: ...for viewing details and working with advanced functionality including Configuration File Controller Software Upgrade Licenses Factory Information User Alarms Custom Data System Menu Web This section...

Страница 65: ...under the Systems menu Figure 44 Systems Data Tiles Most systems will have additional sub menus in the form of live data tiles such as Status Configure System and Inventory Some systems will also have...

Страница 66: ...Loads Disconnects Shunts Other Transducers System Functions Provides sub menus to manage how the system operates e g Charging Temperature Compensation Equalize and Boost Battery Test Battery Runtime...

Страница 67: ...les Firmware Upgrade Provides a table to start and monitor a firmware upgrade Firmware Files Provides a table to view upload or delete firmware files Alarms Menu Web The alarms section has three sub m...

Страница 68: ...d Heath enabled the log will also record the change in State of Charge SOC and State of Health SOH Power Outage The power outage log records the start time end time and duration of each power outage D...

Страница 69: ...HTML Based Emails HTML based emails provide better formatting features such as color coding and table alignment Multi level Security Different security levels are available and automatic detection is...

Страница 70: ...the controller and if TLS is not supported proper degradation of security features is done in the following sequence 1 TLS handshake attempt 2 Clear text authentication with username and password 3 An...

Страница 71: ...agent to send information to the manager Compile the agent s Management Information Bases MIBs into the manager tell the manager how to interpret information sent by the agent 8 3 1 Configuring IP Ad...

Страница 72: ...you to an edit page to configure the appropriate fields Figure 52 Destination 1 More Information Page Clicking the edit icon on the IP address row allows you to insert an IP address of the monitoring...

Страница 73: ...the AC to the FXM HP and allow it to start up Verify that the system starts up and the controller turns on 5 Confirm the battery settings on the controller capacity charge limit the Peukert exponent...

Страница 74: ...sing output line voltage due to the input voltage being lower than specification Line The unit is switched on and line power is provided to the load Buck1 and Buck2 The unit transformer is decreasing...

Страница 75: ...nventory An inventory item is an item that is directly involved in the flow of power through the system For example a battery is an inventory item but a controller or an ADIO is not Setting up the inv...

Страница 76: ...he float charging stage brings the batteries to 100 state of charge and maintains it there When the system is in the float stage it is usually at the Float Voltage 9 2 3 Battery Temperature Compensati...

Страница 77: ...ons Temperature Compensation The value is set based on the battery manufac turer s information If the battery temperature probes appear to be disconnected or broken then the Temp Comp function calcula...

Страница 78: ...tery state of health estimation begins at 3 of DOD but is not displayed unless DOD 20 the point at which reasonable accuracy can be assured Conditions to Watch for During Battery Test If the voltage d...

Страница 79: ...utdown command If the AC Output is turned off manually there are two options for restarting the FXM HP output Manual On The unit remains in shutdown mode The output of the unit must be turned on manu...

Страница 80: ...onds the inverter will run before going to Standby mode Inverter Shutdown Voltage Defines the lower battery voltage limit when the inverter will be turned off The unit goes to Standby mode Once the In...

Страница 81: ...g another ping After retrying for Maximum Protocol Retries times and pinging still fails the FXM HP runs the selected Keep Alive Action Time Periods 1 Defines the first time of day period During this...

Страница 82: ...eep Alive Configuration Table Name Definition Keep Alive Enable Controls the function of running failure action after detecting communication failure Keep Alive Startup Delay Defines the initial time...

Страница 83: ...the inputs and relays to monitor the system 2 Configure each of the system function to correctly control the FXM HP system and manage the battery 3 Adjust threshold enable disable alarm and set up an...

Страница 84: ...Relays Load Shedding Relay Enabled Enabled Time Period 1 6 00 AM 9 00 AM Time Period 2 3 00 PM 6 00 PM Low Battery No Line 1 FXM ADIO C2 Low Battery No Line 2 FXM ADIO C3 On Battery FXM ADIO C1 Relay...

Страница 85: ...Disabled 132V 120V 253V 230V AC Input Low Limit AVR Disabled 108V 120V 207V 230V Battery Capacity Rating 100Ah Battery Open Circuit Voltage 51 4V 48V 25 7V 24V Battery Peukert Exponent 1 00 Battery R...

Страница 86: ...own Trigger Input User Input S3 AC Output Shutdown Operation Manual AC Output Shutdown Auto On Delay 30 seconds AC Output Relay Unassigned AC Output Upper Disconnect Voltage 135V 120V 239V 230V AC Out...

Страница 87: ...aximum Retries 5 Keep Alive Action Failure Restart Delay 40 seconds Low Battery Alarm Threshold 40 Programmable Dry Contact 1 On Battery Alarm Programmable Dry Contact 2 Low Battery No Line 1 Alarm Pr...

Страница 88: ...1 Trigger AC Power Outage Status Timer 1 Activation Delay 2 00 00 Timer 1 Time Period 1 Unassigned Timer 1 Time Period 2 Unassigned Timer 2 Enabled Disabled Timer 2 Relay Unassigned Timer 2 Trigger A...

Страница 89: ...her the LCD touchscreen or the web interface Both have wizard assistance to help step you through the process to create the new system You can create either a 120V or 240V system with a 24V or 48V bat...

Страница 90: ...0170022 J0 Rev A Page 78 To create a FXM HP system 1 Go to Controller Inventory and use the Create FXM System wizard 2 Select the System Type from the drop down menu Click Next...

Страница 91: ...irm the system type detected from the hardware Click Next 4 Select the Configure Battery String option to configure the battery or select Done if finished The battery can be configured later by going...

Страница 92: ...wer Outage Alarm Delay so that power outages shorter than delay setting will be ignored AC Power Outage and On Battery alarms will not be triggered Short power outage events will be logged in the Powe...

Страница 93: ...re the battery temperature values See the following section for instructions on how to do this 8 Configure the battery capacity This value is usually available from the battery specification sheet Use...

Страница 94: ...the minimum average and maximum temperature values as determined from the list of temperatures The system battery temperature should now show a valid reading for battery temperature Configure the Cha...

Страница 95: ...ted Absorption Charging to manually launch Elevated Absorption Charging 9 3 8 Configure the Temperature Compensation System Function The Temperature Compensation function uses the battery temperature...

Страница 96: ...ining battery runtime An accurate estimate of the battery health requires at least one discharge greater than 20 from when the unit is switched on When the unit is powered on the algorithm assumes tha...

Страница 97: ...tem Functions Battery Runtime and Health Estimation 2 From the Configuration table enable Battery Estimation 3 Set the Load Model The load model has no affect on calculating Estimated State of Charge...

Страница 98: ...hen the triggering field is inactive the output of the unit must be turned on manually by going to System FXM HP Configure System and clicking on the Start Up command NOTE AC output will be off due to...

Страница 99: ...tion 1 Go to Controller Advanced Function Soft Shutdown 2 In the Configuration table set the Soft Shutdown System value 3 Verify the Soft Shutdown State is Ready 4 Connect a serial cable from the USB...

Страница 100: ...On Battery status is active To configure the relay activated by On Battery status on the web 1 Go to System FXM System Configuration Alarms page 2 Click on the On Battery detail icon 3 Click on the O...

Страница 101: ...to select a relay to be energized for the corresponding status Low Battery Shutdown To configure the relay activated by Low Battery Shutdown Status on the LCD 1 Go to the System Shortcuts menu and se...

Страница 102: ...re the minimum power outage duration 1 Go to System Configure System 2 From the System Properties table configure Ignore Outage Shorter Than Short power outage will not trigger the alarms but they wil...

Страница 103: ...ress the arrow on the right side of the screen and then LCD displays the menus Status IPv4 Address IPv6 Addresses and Configuration To change the IP address settings 5 Select the Configuration menu to...

Страница 104: ...ent notification through a relay contact closure or opening that an alarm is active On both the web interface and the LCD screen the top left region of the page displays the most recent alarms in orde...

Страница 105: ...ill remain acknowledged 10 2 3 Alarm Activation Delay at Startup Depending on system configuration there may be some alarms that activate shortly after startup then clear a few seconds later These nui...

Страница 106: ...ry Fail Fault Critical Battery appears to have high impedance and has failed Battery Over Voltage Critical Battery Voltage is too high Battery Temperature Probe Unplugged Minor The temperature probe i...

Страница 107: ...Add Threshold User Alarm button 3 Click the details icon Two tables display One table shows the fields to configure that are specific to the selected user alarm The other table shows the standard ala...

Страница 108: ...nfigured Whenever possible test to ensure that new alarm oper ates as expected 10 3 Controller Maintenance This section of the manual covers the following Resetting the controller Powering down the co...

Страница 109: ...ashboard of the controller click Shortcuts then click Reset 2 Click the Execute button to confirm The front screen blacks out and the LED status lights cycle until the reset is complete Once the reset...

Страница 110: ...ress field It is common for gateways and routers to also be SNTP servers If you are unsure of a valid SNTP server address try using the controller s assigned gateway router address If this does not wo...

Страница 111: ...must be approached with caution as it may result in undesired consequences Editing the strings requires familiarity with a spreadsheet program in order to correctly import the file and save the file w...

Страница 112: ...the word strings and end in csv 7 Restart the controller to load the new strings 8 On startup the new strings will be loaded Any errors found while loading the new strings will be logged into the eve...

Страница 113: ...er created from left to right The System Summary Option is Automatic by default but can be customized to display up to four systems slotted in any order required This is done via the System Summary Op...

Страница 114: ...con beside the Dashboard Value you would like to edit NOTE The values in this table will appear on the different dashboards in the order they appear in this table for example Dashboard Value 1 then Da...

Страница 115: ...ther controllers After performing the above procedure other controllers will be able to subscribe to this controller to receive data from it Data Subscriptions Data Subscriptions are a way for users t...

Страница 116: ...d as a No Published Data status 10 3 10 Replacing the Controller Battery To replace the controller battery 1 Shut down the unit 2 Remove the four screws holding the control panel to the unit 3 Gently...

Страница 117: ...ol panel Smooth out the wires and cables so they do not get caught or pinched 6 Replace the four screws 10 4 Working with Logs This section of the manual covers the following Events and Alerts Log Bat...

Страница 118: ...odules without interfering with Alarms or the Event log 10 4 2 Battery Log The Battery log records the duration and change in capacity A h for every charge and discharge of a battery If you have Batte...

Страница 119: ...ncludes the system ID start time end time and duration of each power outage When exported to a csv file the log includes the system ID start time end time and duration of each power outage 10 4 4 Data...

Страница 120: ...e not configured a Datalog will not start If there is a Clock Error Alarm which means that the date has not been set a Datalog will not start If a Datalog is running and a controller reset occurs the...

Страница 121: ...e following information a Name to give the Datalog a name b Description to describe the purpose or usage of the Datalog c Number Of Samples To Capture from 60 to 3600 samples d Sampling Method ADDITIO...

Страница 122: ...the Start Capture command If all of the Data Signals are not configured when the Start Capture button is pressed the capture will still start but an entry is made in the event log to indicate a Data...

Страница 123: ...d hour data into daily data The web displays previews of all four sets of data as they are collected In these previews the horizontal axis shows the data sampled not the time stamp Daily statistics wi...

Страница 124: ...ng that is added to the file name This naming convention applies to most files that can be saved or exported from the controller for example configuration files log files licensing files and backup fi...

Страница 125: ...hieved unambiguously For example if the import is intended to change some configuration for an ADIO but there are more than one ADIO of the same type it will be ambiguous as to which ADIO should recei...

Страница 126: ...the system to that state The Restore functions allows you to take an existing backup file and restore the contents of that file to the system All existing application software and configuration inform...

Страница 127: ...s you to select either a controller a system or an ADIO After the selection is made all asso ciated configurations are presented in a list and are exported by selecting the check box For example to ex...

Страница 128: ...is performed when a file that has been exported using Export System or ADIO is uploaded The system or ADIO contained in the file is added to the controller If a system is being imported the new system...

Страница 129: ...ace ADIO if required When this operation is done the controller gives special atten tion to the status of relays mapped to a disconnect If as a result of the replace operation a disconnect relay will...

Страница 130: ...Battery Log Daily statistics for all Performance Logs Datalogs Additionally if any T2S modules for the AMPS HP2 system are acquired an additional step will be avail able in the Export Diagnostic Infor...

Страница 131: ...If initiated from the WEB it is downloaded to the PC Depending on the amount of data to download it may take several minutes to complete This file can now be opened in a spreadsheet program for analys...

Страница 132: ...r Roles drop down menu you can configure the privileges each user has as well as create passwords The different levels of user permissions are as follows Administrator Can modify all configurations pe...

Страница 133: ...e 4 Optional Edit the Alias and click Save The alias field allows login names that a user is more familiar with For example if you set the operator1 alias to TL1 you can login to the operator1 account...

Страница 134: ...istrator or Account Manager privileges User accounts are not actually deleted they are edited to remove a user s access to the system To disable users 1 Go to Controller Configure Controller Users and...

Страница 135: ...Menu button 2 Press Controller to highlight it and then press the arrow on the right side 3 Press to highlight Configure Controller and then press the arrow on the right side 4 Swipe with an upward m...

Страница 136: ...ia the web interface To change the default password via the web 1 From the main dashboard go to Controller Configure Controller Users and Security 2 From the admin line click the more details icon on...

Страница 137: ...ockout 2 Click the edit icon beside Remove Configuration Lockout change the value to Disabled logging in if required then save 3 Click the edit icon beside Lockout Override Time enter in the desired t...

Страница 138: ...7 2 Uploading a Firmware File Uploading a Firmware File from the LCD From the LCD you can either choose a file uploaded from a USB drive or one from the Local Files folder The Local Files menu contai...

Страница 139: ...les and click Upload Firmware File table Figure 66 Firmware Files Table 2 An Upload File dialog displays 3 Click the Select File and choose the file to upload Once a firmware file is selected click th...

Страница 140: ...y uploaded files Local Files or from a USB drive Once a file is selected the first three rows of the table are updated with new status If the file chosen is not a valid upgrade file or if there are no...

Страница 141: ...ent complete will show the total 100 will be reached once all modules are upgraded instead of a per module completion Figure 69 Upgrade in Progress The firmware upgrade can be stopped if necessary If...

Страница 142: ...0170022 J0 Rev A Page 130 Figure 70 Upgrade Succeeded...

Страница 143: ...s set to Circuit Open the FXM HP is triggered to perform the assigned action when the User Input circuit is open To configure the user input s active level 1 Go to Module 2 In the All Module table cli...

Страница 144: ...0170022 J0 Rev A Page 132...

Страница 145: ...ages or consequential damages based upon equipment failure during or after the warranty period No other obligations are expressed or implied Warranty also does not cover damage or equipment failure du...

Страница 146: ...0170022 J0 Rev A Page 134...

Страница 147: ...d to CSA C22 2 No 107 3 and UL 1778 As part of the reciprocal US Canada agreement regarding testing laboratories the Standards Council of Canada Canada s national accreditation body granted Underwrite...

Страница 148: ......

Страница 149: ......

Страница 150: ...to make changes to the products and information contained in this document without notice Copyright 2019 Alpha Technologies All Rights Reserved Alpha is a registered trademark of Alpha Technologies ww...

Отзывы: