T
able 2, QRC: Quick Refer
ence Chart • Pump Firmwar
e V
ersion 7.x • Pump T
ypes 1, 2, 3, 6, 8 and 10
Step
Switch
T
ext
Display
Expected r
eading / symbol / status
digital display
Units
Comments
1
READY
0
PSI, BAR,
or MPa
Firmwar
e version 7.x, pump type (1, 2, 3, 6, 8 or 10)
and motor type (UN, IP or 3P) will briefl
y appear on LCD.
“READY” appears after power on and boot sequence has completed.
2A
X
SET UNITS
PSI
Save pr
evious setting and step forwar
d to select units,
PSI, BAR or MPa. Default is PSI.
X"
BAR
X"
MPa
X
Save and step to #3 by pr
essing Menu button.
2B
X
SET UNITS
Hold for 7 Seconds
Save pr
evious setting and step forwar
d to select units,
PSI, BAR or MPa. Default is PSI.
X
X
"
Hold for 7 Seconds
CAL PT A
0
PSI, BAR,
or MPa
Start calibration pr
ocess.
See T
able 2, calibration r
efer
ence chart for further instructions.
3A
X
AUTOMODE
OFF
Toggle between “ON” and “OFF” using the Arr
ow buttons.
XO
N
X
Save and step to #3B by pr
essing Menu button.
Note:
T
o step to #5 Motor scr
een, tur
n Automode OFF
and pr
ess Menu button.
3B
SET
HI PRESS
XXXXX (PSI, BAR or MPa)
PSI, BAR
or MPa
If Automode is ON.
Set maximum pr
essur
e (upper Automode limit),
default value is 10,500 psi [724 bar].
Note:
Pr
essur
e not adjustable when Automode is OFF
.
X
"
Up 50 psi [4 bar] per 0.5 sec. for fi
rst 3 sec.
Then up 50 psi [4 bar] every 0.05 sec.
"
Only if pr
essur
e transducer is detected,
hold down button for 4 sec. minimum.
X
"
Down 50 psi [4 bar] per 0.5 sec. for fi
rst 3 sec.
Then down 50 psi [4 bar] every 0.05 sec.
"
Only if pr
essur
e transducer is detected,
hold down button for 4 sec. minimum.
X
Save and step to #3C by pr
essing Menu button.
3C
SET
LO PRESS
XXXXX (PSI, BAR or MPa)
PSI, BAR
or MPa
If Automode is ON.
Set minimum pr
essur
e (lower Automode limit),
default value is OFF
.
Note:
Pr
essur
e not adjustable when Automode is OFF
.
X
"
Up 50 psi [4 bar] per 0.5 sec. for fi
rst 3 sec.
Then up 50 psi [4 bar] every 0.05 sec.
"
Only if pr
essur
e transducer is detected,
hold down button for 4 sec. minimum.
X
"
Down 50 psi [4 bar] per 0.5 sec. for fi
rst 3 sec.
Then down 50 psi [4 bar] every 0.05 sec.
"
Only if pr
essur
e transducer is detected,
hold down button for 4 sec. minimum.
X
Save and step to #5 by pr
essing Menu button.
(Continued on next page)