4.0  AUTOMATIC PUMP OPERATION
(Pumps equipped with pressure transducer option)

Pumps equipped with the pressure transducer option have the 
ability to react automatically at a user-defi ned upper and lower 
pressure value. This feature is called “Automode”.

Automode can be turned on or off as desired, at the LCD control 
panel.

Automode controlled operation of the motor and electric valve 
(if equipped) will vary, depending on pump type . The pump type 
appears briefl y on the LCD when power is connected to the 
pump. 

Refer to Table 1 for a list of the pump types covered in this 
manual. Refer to Table 4, 

Pump Model Matrix

, (located near the 

end of this document) for a description of the specifi c operational 
characteristics for each pump type.

Table 1 - Pump Types

    Number                                        Pump/Valve Description

 

1 . . . . . . . . . . . . . . . . . . . Manual w/LCD (manual valve)

 

2 . . . . . . . . . . . . . . . . . . . Advance/Hold /Retract (electric valve)

 

3 . . . . . . . . . . . . . . . . . . . Dump (electric valve)

 

6 . . . . . . . . . . . . . . . . . . . Remote 3 or 4-Way (electric valve)

 

8 . . . . . . . . . . . . . . . . . . . Jog (manual valve)

 

10  . . . . . . . . . . . . . . . . . . 3 or 4-Way Manual Momentary

 

 . . . . . . . . . . . . . . . . . . .

Local Mode Default

 

(electric valve)

4.1  Overview of Automode Operation

Refer to paragraphs A through  D of this section for an overview 
of Automode operation and features.

4.1 A. If Automode is ON, and LO PRESS setting is 
greater than zero 

(Pump types 1, 2, 6, 8 and 10)

I. Before the HI PRESS value is reached:

• The pendant buttons and shroud On/Off button will function as 
described in sections 3.1 – 3.4.

•   The text “AUTO” will be shown on the LCD, reminding the 
operator that Automode is active, and that the pump will take 
control when system pressure rises to the HI PRESS value.

II. After the HI PRESS value is reached:

•    

Pump types 1 and 8:

 The pump motor will stop.

•    

Pump type 2:

 The pump motor will stop and the electric valve 

will shift.

•    

Pump types 6 and 10:

 The pump motor will keep running and 

the electric valve will shift.

•   The LCD text will change from “AUTO” to “AUTO ON” and the 
LCD backlight will begin fl ashing on and off. This indicates that 
Automode is now controlling pump operation automatically as 
required to maintain the set pressure range.

WARNING: 

All personnel must be aware that motor can 

start and/or valve can shift at any time when backlight 
is fl ashing and “AUTO ON” is displayed on the LCD.

WARNING: 

Always set Automode to OFF and 

disconnect electrical power to pump before 
disconnecting hoses or performing any 
adjustments,  maintenance or repairs.

III. When system pressure drops to the LO PRESS value:

•   

Pump types 1 and 8:

 The pump motor will restart.

•   

Pump types 6 and 10:

 The electric valve will shift.

•    

Pump type 2:

 The pump motor will restart and the electric 

valve will shift.

4.1 B. If Automode is ON, and LO PRESS setting is set 
to zero (0) or OFF 

(Pump types 1, 2, 3, 6, 8 and 10)

Note:

 On pump type 3 only, the LO PRESS function is not used, 

and is automatically set to zero (0) by the microcontroller.

I. Before the HI PRESS value is reached:

•   The pendant buttons and shroud On/Off button will function 
as described in sections 3.1 – 3.4.

•   The text “AUTO” will be shown on the LCD, reminding the 
operator that Automode is active, and that the pump will take 
control when system pressure rises to the HI PRESS value.

II. After the HI PRESS value is reached:

•    

Pump types 1, 2, 3 and 8:

 The pump motor will stop and the 

electric valve will shift.

•    

Pump types 6 and 10:

 The pump motor will keep running and 

the electric valve will shift.

•    The LCD will continue to display “AUTO” and the LCD backlight 

will remain turned on (will not fl ash on and off).

4.1 C. If Automode is OFF

(Pump types 1, 2, 3, 6, 8 and 10)

•   The LCD will display “READY” in the text area.

•   The LCD will indicate system pressure as a simple pressure 
gauge, no additional actions will be performed regardless of 
previously set HI PRESS and LO PRESS values.

4.1 D.  Additional  Information

•   Pressing and releasing any button on the pendant (if equipped) 
or shroud will stop the automatic cycle. Pressing the pendant 
Down-Arrow (if applicable) will also retract the cylinder. Pressing 
the motor On/Off button will also de-energize the motor if it is 
running.

•   To restart the automatic cycle, press and release the pendant 
Up-Arrow button (if applicable) or the motor On/Off button (See 
section 3.1– 3.4).

•   Refer to sections 6.1 through 6.5 later in this document for 
and detailed LCD operating instructions and descriptions of the 
Automode LCD screens.

3

Содержание Z 1 0 Series

Страница 1: ...re back pressure Sharp bends and kinks will internally damage the hose leading to premature hose failure Do not drop heavy objects on hose A sharp impact may cause internal damage to hose wire strands Applying pressure to a damaged hose may cause it to rupture IMPORTANT Do not lift hydraulic equipment by the hoses or swivel couplers Use the carrying handle or other means of safe transport CAUTION ...

Страница 2: ...gh 3 4 for instructions applicable to your specific valve and pendant configuration For models equipped with a foot switch refer to section 3 5 3 0 VALVE PENDANT AND FOOT SWITCH OPERATION 3 1 Manual Valve Operation VM32 See Fig 1 1 Advance 2 Retract Shroud On Off Toggle Motor On or Off 3 2 VM33 VM33L VM43 and VM43L See Fig 2 1 Advance 2 Retract 3 Neutral Shroud On Off Toggle Motor On or Off Figure...

Страница 3: ...personnel must be aware that motor can start and or valve can shift at any time when backlight is flashing and AUTO ON is displayed on the LCD WARNING Always set Automode to OFF and disconnect electrical power to pump before disconnecting hoses or performing any adjustments maintenance or repairs III When system pressure drops to the LO PRESS value Pump types 1 and 8 The pump motor will restart Pu...

Страница 4: ... and the button switches is not broken or otherwise damaged Never punch the button switches with a sharp or pointed instrument use fingertips only Clean the overlay regularly with a damp cloth Never use aggressive or abrasive detergents Text Display Numeric Display SET 00000000 0000 0 PSI MPa BAR HOURS CYCLES LOW MOTOR VOLTAGE OVERLOAD Figure 6 LCD Control Panel 6 2 Boot Sequence When the pump is ...

Страница 5: ...etting and step forward by pressing the Menu button Refer to QRC step 2 6 5C Automode Menu SET Screen 3 ON AUTOMODE See Screen 3 This screen allows the operator to activate or de activate automatic operation of the pump motor and electric valve if equipped Toggle Automode ON or OFF by pressing either the Up or Down Arrow button Save setting and step forward by pressing the Menu button Refer to QRC...

Страница 6: ...ailable 6 5G Motor Menu MOTOR 4 8 HOURS CYCLES Screen 7 See Screen 7 This screen allows the operator to read the number of hours or on off cycles the motor has been operated Toggle between hours and cycles by pushing either the Down or Up Arrow button Step forward by pressing the Menu button Refer to QRC step 5 __________________________________________________________ General note for all hour an...

Страница 7: ...d hold both the Down Arrow and Up Arrow button for 7 seconds See Table 3 Z Class Pressure Transducer Calibration for adjustment steps 6 7 LCD Fault Conditions Any fault condition will shut down the pump and prevent it from starting 6 7A Clearing a Fault Condition from the LCD After the fault causing problem has been corrected clear the fault message from the LCD by disconnecting electrical power f...

Страница 8: ... in the valve manifold GA port However if desired the pressure switch can be installed in the valve manifold GB or GP ports GA measures A port pressure GB measures B port pressure if applicable GP measures pump pressure before the control valve 6 8 LCD Warning Conditions LCD Warnings notify the operator of abnormal operating conditions but allow the pump to continue operating Warnings will automat...

Страница 9: ...nd press Menu button 3B SET HI PRESS XXXXX PSI BAR or MPa PSI BAR or MPa If Automode is ON Set maximum pressure upper Automode limit default value is 10 500 psi 724 bar Note Pressure not adjustable when Automode is OFF X Up 50 psi 4 bar per 0 5 sec for fi rst 3 sec Then up 50 psi 4 bar every 0 05 sec Only if pressure transducer is detected hold down button for 4 sec minimum X Down 50 psi 4 bar per...

Страница 10: ...X Number of cycles CYCLES Select cycle counter function solenoid advance 8 X RETRACT Number of hours displayed as 0 0 HOURS Select hour meter function solenoid retract X Number of cycles CYCLES Select cycle counter function solenoid retract 9 X LOCAL OFF Select LOCAL mode Toggle between ON and OFF X ON X OFF 10 X ENGLISH Select language default is English X ESPANOL X FRANCAIS X ITALIANO X DEUTSCH ...

Страница 11: ...ar 5000 psi 345 bar no yes 8000 psi 548 bar 8000 psi 548 bar no yes off O psi O bar O psi O bar FIRMWARE 7 x then READY UNITS ENTRY CAL PT A CAL PT A SAVE A SAVE A CAL PT B CAL PT B SAVE B SAVE B CAL PT C CAL PT C SAVE C SAVE C USE DFLT CAL PT A READY Operator action Connect a master gauge to port A Advance port Connect electrical power to pump At main screen press the Menu button once to display ...

Страница 12: ...0 means LO_PRES is turned off Default manufacturer setting is AUTO MODE off LO_PRESS is 0 What happens when _____ button is pushed in normal operation mode READY is displayed on LCD Pendant Button LCD Panel Button Action when HI_PRESS value is reached Max value for HI_PRESS Additional comments valve any manual VE32 VE32 D VE33 VE43 none on on na na can not change LO_PRESS value from off na can not...

Страница 13: ...o change off no change momentary on Note Motor may be on or off advance off toggle on off see note 1 off off when HI_PRESS is reached only the valve shuts off motor continues running off off 10 500 psi Similar to pump No 6 execpt that LOCAL MODE is the default at start up Pendant buttons are disabled See Note 2 VE33 VE43 none na on off na 50 psi less than HI_PRESS current value 0 means LO_PRESS is...

Страница 14: ...co Milano Tel 39 02 4861 111 Fax 39 02 4860 1288 Japan Applied Power Japan LTD KK Besshochou 85 7 Kita ku Saitama shi 331 0821 Japan Tel 81 48 662 4911 Fax 81 48 662 4955 Middle East Turkey and Caspian Sea ENERPAC Middle East FZE Office 423 JAFZA 15 P O Box 18004 Jebel Ali Dubai United Arab Emirates Tel 971 0 4 8872686 Fax 971 0 4 8872687 Russia and CIS excl Caspian Sea Countries Actuant LLC Admir...

Отзывы: