6.5 L  “Language” Menu

       ENGLISH  

SET

Screen 12

(See Screen 12) This screen allows 
the operator to change the LCD display 
language. When a language is shown on 
the LCD, press the Down or Up Arrow 
buttons to select a different language. Save 
setting and step forward by pressing the 
Menu button. Refer to QRC step #10.

6.5 M  “Diagnose” Menu

Pendant 

on/off

 button

Pendant 

advance

 

button

Pendant 

retract

 

button

(not used)
(not used)

DIAGNOSE

 00001

Screen 13

PSI   MPa

BAR Nm   

Ft-lb

(See Screen 13) This screen allows 
the operator to troubleshoot various 
pendant problems. If the number “1” 
does not appear when a pendant button 
is pushed, problems with the pendant 
button switches and/or pendant cord 
may be present (See Screens 14, 15 and 
16). Use Local mode to operate pump 
until problem can be corrected. Refer to 
QRC step #11.

Press

Screen 14

   DIAGNOSE

01001

PSI   MPa
BAR    Nm
Ft-lb

Diagnose screen 
with pendant

on/off 

button 

pushed.

Press

Screen 15

   DIAGNOSE

10001

PSI   MPa
BAR    Nm
Ft-lb

Diagnose screen 
with pendant 

advance

 button 

pushed.

Press

Screen 16

   DIAGNOSE

00101

PSI   MPa
BAR    Nm
Ft-lb

Diagnose screen 
with pendant 

retract

 button 

pushed.

6.6  LCD Hidden Menus

6.6 A  “Calibration” Menu

CAL PT A

         0

SET

Screen 17

PSI

(See Screen 17) This screen allows the 
operator to adjust the pressure value 
shown on the LCD to match a master 
gauge.

To access this menu, go to the “UNITS” 
menu.

Then, press and hold the shroud
Motor on/off button in for 7 seconds. ENTRY CODE will appear. 
Then, press and hold both the Down Arrow and Up Arrow button 
for 7 seconds. See Table 3, “Z-Class Pressure Transducer 
Calibration” for adjustment steps.

6.7  LCD Fault Conditions

Any fault condition will shut down the pump and prevent it from 
starting.

6.7 A  Clearing a Fault Condition from the LCD

After the fault causing problem has been corrected, clear the fault 
message from the LCD by disconnecting electrical power from 
the pump. Wait until all characters clear the LCD (~ 10 seconds), 
then reconnect power.

 6.7 B  Power Failure

     

Display: “POWER OFF”

POWER

OFF

Screen 18

 

(See Screen 18) The Power Off fault is 
displayed when the main power supply 
drops to 65% or less of nominal voltage. 
The pump will automatically shut-off 
the valve solenoid and the motor, and 
display “Power Off” on the LCD. 

Note: 

Power Off is also displayed for several 
seconds after the unit is disconnected 
from electrical power.

6.7 C  Button Fault

  

   Display: “BUTTON FAULT”

BUTTON

FAULT

Screen 19

(See Screen 19) The Button Fault 
message is displayed when the 
microcontroller detects that any button 
is pressed during the boot sequence 
or if the shroud Motor on/off button is 
pressed for more than 3 seconds.

6.7 D  Motor Overload

     

Display: “MTR OVLD” and 

“Motor Overload” 

MTR OVLD

Screen 20

MOTOR
OVERLOAD

(See Screen 20) The Motor Overload 
fault is displayed when the electric 
current draw exceeds the pre-set limit 
of the pump’s internal circuit breaker. 
The circuit breaker will automatically 
reset in about 2 to 3 minutes after the 
condition has been corrected. However, 
before the pump can be restarted, the 
operator must clear the fault by disconnecting and reconnecting 
electrical power as described in section 5.7

 

A.

Содержание Z 1 0 Series

Страница 1: ...re back pressure Sharp bends and kinks will internally damage the hose leading to premature hose failure Do not drop heavy objects on hose A sharp impact may cause internal damage to hose wire strands Applying pressure to a damaged hose may cause it to rupture IMPORTANT Do not lift hydraulic equipment by the hoses or swivel couplers Use the carrying handle or other means of safe transport CAUTION ...

Страница 2: ...gh 3 4 for instructions applicable to your specific valve and pendant configuration For models equipped with a foot switch refer to section 3 5 3 0 VALVE PENDANT AND FOOT SWITCH OPERATION 3 1 Manual Valve Operation VM32 See Fig 1 1 Advance 2 Retract Shroud On Off Toggle Motor On or Off 3 2 VM33 VM33L VM43 and VM43L See Fig 2 1 Advance 2 Retract 3 Neutral Shroud On Off Toggle Motor On or Off Figure...

Страница 3: ...personnel must be aware that motor can start and or valve can shift at any time when backlight is flashing and AUTO ON is displayed on the LCD WARNING Always set Automode to OFF and disconnect electrical power to pump before disconnecting hoses or performing any adjustments maintenance or repairs III When system pressure drops to the LO PRESS value Pump types 1 and 8 The pump motor will restart Pu...

Страница 4: ... and the button switches is not broken or otherwise damaged Never punch the button switches with a sharp or pointed instrument use fingertips only Clean the overlay regularly with a damp cloth Never use aggressive or abrasive detergents Text Display Numeric Display SET 00000000 0000 0 PSI MPa BAR HOURS CYCLES LOW MOTOR VOLTAGE OVERLOAD Figure 6 LCD Control Panel 6 2 Boot Sequence When the pump is ...

Страница 5: ...etting and step forward by pressing the Menu button Refer to QRC step 2 6 5C Automode Menu SET Screen 3 ON AUTOMODE See Screen 3 This screen allows the operator to activate or de activate automatic operation of the pump motor and electric valve if equipped Toggle Automode ON or OFF by pressing either the Up or Down Arrow button Save setting and step forward by pressing the Menu button Refer to QRC...

Страница 6: ...ailable 6 5G Motor Menu MOTOR 4 8 HOURS CYCLES Screen 7 See Screen 7 This screen allows the operator to read the number of hours or on off cycles the motor has been operated Toggle between hours and cycles by pushing either the Down or Up Arrow button Step forward by pressing the Menu button Refer to QRC step 5 __________________________________________________________ General note for all hour an...

Страница 7: ...d hold both the Down Arrow and Up Arrow button for 7 seconds See Table 3 Z Class Pressure Transducer Calibration for adjustment steps 6 7 LCD Fault Conditions Any fault condition will shut down the pump and prevent it from starting 6 7A Clearing a Fault Condition from the LCD After the fault causing problem has been corrected clear the fault message from the LCD by disconnecting electrical power f...

Страница 8: ... in the valve manifold GA port However if desired the pressure switch can be installed in the valve manifold GB or GP ports GA measures A port pressure GB measures B port pressure if applicable GP measures pump pressure before the control valve 6 8 LCD Warning Conditions LCD Warnings notify the operator of abnormal operating conditions but allow the pump to continue operating Warnings will automat...

Страница 9: ...nd press Menu button 3B SET HI PRESS XXXXX PSI BAR or MPa PSI BAR or MPa If Automode is ON Set maximum pressure upper Automode limit default value is 10 500 psi 724 bar Note Pressure not adjustable when Automode is OFF X Up 50 psi 4 bar per 0 5 sec for fi rst 3 sec Then up 50 psi 4 bar every 0 05 sec Only if pressure transducer is detected hold down button for 4 sec minimum X Down 50 psi 4 bar per...

Страница 10: ...X Number of cycles CYCLES Select cycle counter function solenoid advance 8 X RETRACT Number of hours displayed as 0 0 HOURS Select hour meter function solenoid retract X Number of cycles CYCLES Select cycle counter function solenoid retract 9 X LOCAL OFF Select LOCAL mode Toggle between ON and OFF X ON X OFF 10 X ENGLISH Select language default is English X ESPANOL X FRANCAIS X ITALIANO X DEUTSCH ...

Страница 11: ...ar 5000 psi 345 bar no yes 8000 psi 548 bar 8000 psi 548 bar no yes off O psi O bar O psi O bar FIRMWARE 7 x then READY UNITS ENTRY CAL PT A CAL PT A SAVE A SAVE A CAL PT B CAL PT B SAVE B SAVE B CAL PT C CAL PT C SAVE C SAVE C USE DFLT CAL PT A READY Operator action Connect a master gauge to port A Advance port Connect electrical power to pump At main screen press the Menu button once to display ...

Страница 12: ...0 means LO_PRES is turned off Default manufacturer setting is AUTO MODE off LO_PRESS is 0 What happens when _____ button is pushed in normal operation mode READY is displayed on LCD Pendant Button LCD Panel Button Action when HI_PRESS value is reached Max value for HI_PRESS Additional comments valve any manual VE32 VE32 D VE33 VE43 none on on na na can not change LO_PRESS value from off na can not...

Страница 13: ...o change off no change momentary on Note Motor may be on or off advance off toggle on off see note 1 off off when HI_PRESS is reached only the valve shuts off motor continues running off off 10 500 psi Similar to pump No 6 execpt that LOCAL MODE is the default at start up Pendant buttons are disabled See Note 2 VE33 VE43 none na on off na 50 psi less than HI_PRESS current value 0 means LO_PRESS is...

Страница 14: ...co Milano Tel 39 02 4861 111 Fax 39 02 4860 1288 Japan Applied Power Japan LTD KK Besshochou 85 7 Kita ku Saitama shi 331 0821 Japan Tel 81 48 662 4911 Fax 81 48 662 4955 Middle East Turkey and Caspian Sea ENERPAC Middle East FZE Office 423 JAFZA 15 P O Box 18004 Jebel Ali Dubai United Arab Emirates Tel 971 0 4 8872686 Fax 971 0 4 8872687 Russia and CIS excl Caspian Sea Countries Actuant LLC Admir...

Отзывы: