Pump

Type

1

2

3

6

Pump

type

manual

w/LCD

Adv

/

Hold

/

Ret

Dump

remote

3/4-way

Pump

type

code

ZxxxxxLx

ZxxxxxHx

Zxx2xxSx

Zxx1xxDx

Zxx3xxSx

Zxx4xxSx

ZxxxxxWx

pendant

none

3-button

1-button

3-button

none

Item

Motor

&

Fan

(if

attached)

Motor

&

Fan

(if

attached)

Solenoid

B

Motor

&

Fan

(if

attached)

Solenoid

A

Motor

&

Fan

(if

attached)

Solenoid

A

Solenoid

B

Motor

On/Off

na

-

no

pendant

na

-

disabled

na

-

disabled

na

-

disabled

na

-

disabled

toggle

on/off

no

change

no

change

Arrow

down

na

-

no

pendant

na

-

disabled

momentar

y

on

(retract)

na

-

disabled

na

-

disabled

no

change

off

momentar

y

on

(retract)

Arrow

up

na

-

no

pendant

momentar

y

on

(advance)

na

-

disabled

momentar

y

on

(advance)

momentar

y

on

(advance)

no

change

momentar

y

on

(advance)

off

Motor

On/Off

toggle

on/off

off

off

off

off

toggle

on/off

off

off

off

off

off

off

off

when

HI_PRESS

is

reached

only

the

valve

shuts

off,

motor

continues

running

off

off

10,500

psi

10,500

psi

10,500

psi

10,500

psi

3

button

pendant

used

but

only

Up

and

Do

wn

Arro

w

buttons

are

active

up-arro

w

no

w

on

the

middle

button-position,

using

pin

#2

of

pendant

Pump

type

6

is

the

default

factor

y

setting.

0

means

LO_PRES

is

turned

off.

Default

manufacturer

setting

is

AUTO

MODE

off

&

LO_PRESS

is

0

What

happens

when

_____

button

is

pushed

in

normal

operation

mode

(“READY”

is

displayed

on

LCD)

Pendant

Button

LCD

Panel

Button

Action

when

HI_

PRESS

va

lu

e

is reached

Max

value

for

HI_PRES

S

Additional

comments

valve

an

y

manual

VE32

VE32-D

VE33

/

VE43

none

on

on

na

na

-

can

not

change

LO_PRESS value

from

off

na

-

can

not

change

LO_PRESS

value

from

off

na

on

off

Action

when

LO_PRES

S

value

is

reac

hed

50

psi

less

than

HI_PRESS

current

value.

0

means

LO_PRESS

is

turned

off.

50

psi

less

than

HI_PRESS

current

value.

0

means

LO_PRESS

is

turned

off.

na

-

can

not

change

LO_

PRESS

value

from

off

na

50

psi

less

than

HI_PRESS current

value.

0

means

LO_PRESS

is

turned

off

na

Max

value

for

LO_PRESS

Operation with Automode ON

Pumps Equipped with Pressure Transducer Option Only

foot

switch

NA

Option

Option

Option

8

Jog

ZxxxxxKx

1o

r2

-

button

Motor

&

Fan

(if

attached)

toggle

on/off

momentar

y

on

momentar

y

on

toggle

on/off

off

10,500

psi

safety

fea

ture:

Arro

w-up

and

arro

w-do

wn

buttons

switch

off

motor

when

pump

is

running

on

toggle-on

an

y

manual

on

50

psi

less

than

HI_PRESS

current

value.

0

means

LO_PRESS is

turned

off.

Option

T

able 4, Z-Class Pump Model Matrix  •  Firmwar

e 7.x  •  Pump T

ypes 1, 2, 3, 6, 8 and 10

(Continued on next page)

Содержание Z 1 0 Series

Страница 1: ...re back pressure Sharp bends and kinks will internally damage the hose leading to premature hose failure Do not drop heavy objects on hose A sharp impact may cause internal damage to hose wire strands Applying pressure to a damaged hose may cause it to rupture IMPORTANT Do not lift hydraulic equipment by the hoses or swivel couplers Use the carrying handle or other means of safe transport CAUTION ...

Страница 2: ...gh 3 4 for instructions applicable to your specific valve and pendant configuration For models equipped with a foot switch refer to section 3 5 3 0 VALVE PENDANT AND FOOT SWITCH OPERATION 3 1 Manual Valve Operation VM32 See Fig 1 1 Advance 2 Retract Shroud On Off Toggle Motor On or Off 3 2 VM33 VM33L VM43 and VM43L See Fig 2 1 Advance 2 Retract 3 Neutral Shroud On Off Toggle Motor On or Off Figure...

Страница 3: ...personnel must be aware that motor can start and or valve can shift at any time when backlight is flashing and AUTO ON is displayed on the LCD WARNING Always set Automode to OFF and disconnect electrical power to pump before disconnecting hoses or performing any adjustments maintenance or repairs III When system pressure drops to the LO PRESS value Pump types 1 and 8 The pump motor will restart Pu...

Страница 4: ... and the button switches is not broken or otherwise damaged Never punch the button switches with a sharp or pointed instrument use fingertips only Clean the overlay regularly with a damp cloth Never use aggressive or abrasive detergents Text Display Numeric Display SET 00000000 0000 0 PSI MPa BAR HOURS CYCLES LOW MOTOR VOLTAGE OVERLOAD Figure 6 LCD Control Panel 6 2 Boot Sequence When the pump is ...

Страница 5: ...etting and step forward by pressing the Menu button Refer to QRC step 2 6 5C Automode Menu SET Screen 3 ON AUTOMODE See Screen 3 This screen allows the operator to activate or de activate automatic operation of the pump motor and electric valve if equipped Toggle Automode ON or OFF by pressing either the Up or Down Arrow button Save setting and step forward by pressing the Menu button Refer to QRC...

Страница 6: ...ailable 6 5G Motor Menu MOTOR 4 8 HOURS CYCLES Screen 7 See Screen 7 This screen allows the operator to read the number of hours or on off cycles the motor has been operated Toggle between hours and cycles by pushing either the Down or Up Arrow button Step forward by pressing the Menu button Refer to QRC step 5 __________________________________________________________ General note for all hour an...

Страница 7: ...d hold both the Down Arrow and Up Arrow button for 7 seconds See Table 3 Z Class Pressure Transducer Calibration for adjustment steps 6 7 LCD Fault Conditions Any fault condition will shut down the pump and prevent it from starting 6 7A Clearing a Fault Condition from the LCD After the fault causing problem has been corrected clear the fault message from the LCD by disconnecting electrical power f...

Страница 8: ... in the valve manifold GA port However if desired the pressure switch can be installed in the valve manifold GB or GP ports GA measures A port pressure GB measures B port pressure if applicable GP measures pump pressure before the control valve 6 8 LCD Warning Conditions LCD Warnings notify the operator of abnormal operating conditions but allow the pump to continue operating Warnings will automat...

Страница 9: ...nd press Menu button 3B SET HI PRESS XXXXX PSI BAR or MPa PSI BAR or MPa If Automode is ON Set maximum pressure upper Automode limit default value is 10 500 psi 724 bar Note Pressure not adjustable when Automode is OFF X Up 50 psi 4 bar per 0 5 sec for fi rst 3 sec Then up 50 psi 4 bar every 0 05 sec Only if pressure transducer is detected hold down button for 4 sec minimum X Down 50 psi 4 bar per...

Страница 10: ...X Number of cycles CYCLES Select cycle counter function solenoid advance 8 X RETRACT Number of hours displayed as 0 0 HOURS Select hour meter function solenoid retract X Number of cycles CYCLES Select cycle counter function solenoid retract 9 X LOCAL OFF Select LOCAL mode Toggle between ON and OFF X ON X OFF 10 X ENGLISH Select language default is English X ESPANOL X FRANCAIS X ITALIANO X DEUTSCH ...

Страница 11: ...ar 5000 psi 345 bar no yes 8000 psi 548 bar 8000 psi 548 bar no yes off O psi O bar O psi O bar FIRMWARE 7 x then READY UNITS ENTRY CAL PT A CAL PT A SAVE A SAVE A CAL PT B CAL PT B SAVE B SAVE B CAL PT C CAL PT C SAVE C SAVE C USE DFLT CAL PT A READY Operator action Connect a master gauge to port A Advance port Connect electrical power to pump At main screen press the Menu button once to display ...

Страница 12: ...0 means LO_PRES is turned off Default manufacturer setting is AUTO MODE off LO_PRESS is 0 What happens when _____ button is pushed in normal operation mode READY is displayed on LCD Pendant Button LCD Panel Button Action when HI_PRESS value is reached Max value for HI_PRESS Additional comments valve any manual VE32 VE32 D VE33 VE43 none on on na na can not change LO_PRESS value from off na can not...

Страница 13: ...o change off no change momentary on Note Motor may be on or off advance off toggle on off see note 1 off off when HI_PRESS is reached only the valve shuts off motor continues running off off 10 500 psi Similar to pump No 6 execpt that LOCAL MODE is the default at start up Pendant buttons are disabled See Note 2 VE33 VE43 none na on off na 50 psi less than HI_PRESS current value 0 means LO_PRESS is...

Страница 14: ...co Milano Tel 39 02 4861 111 Fax 39 02 4860 1288 Japan Applied Power Japan LTD KK Besshochou 85 7 Kita ku Saitama shi 331 0821 Japan Tel 81 48 662 4911 Fax 81 48 662 4955 Middle East Turkey and Caspian Sea ENERPAC Middle East FZE Office 423 JAFZA 15 P O Box 18004 Jebel Ali Dubai United Arab Emirates Tel 971 0 4 8872686 Fax 971 0 4 8872687 Russia and CIS excl Caspian Sea Countries Actuant LLC Admir...

Отзывы: