6.2.3 Imperial System Torque Factor Calculation
To set the torque, adjust the pump pressure according to the following calculation:
Pump pressure (psi) = Torque (Ft.lbs) / Torque Factor
S1500X S3000X S6000X S11000X
S25000X
Torque Factor
Imperial
System:
0.144 0.3225 0.615 1.1175
2.515
6.2.4 Imperial System Pressure/Torque Conversion Table
S1500X S3000X S6000X S11000X S25000X
Pump pressure
Torque
Torque
Torque
Torque
Torque
(psi)
(Ft.lbs) (Ft.lbs) (Ft.lbs) (Ft.lbs) (Ft.lbs)
1,000
144 323 615 1,118 2,515
1,500
216 484 923 1,676 3,773
2,000
288 645 1,230 2,235 5,030
2,500
360 806 1,538 2,794 6,288
3,000
432 968 1,845 3,353 7,545
3,500
504 1,129 2,153 3,911 8,803
4,000
576 1,290 2,460 4,470 10,060
4,500
648 1,451 2,768 5,029 11,318
5,000
720 1,613 3,075 5,588 12,575
5,500
792 1,774 3,383 6,146 13,833
6,000
864 1,935 3,690 6,705 15,090
6,500
936 2,096 3,998 7,264 16,348
7,000
1,008 2,258 4,305 7,823 17,605
7,500
1,080 2,419 4,613 8,381 18,863
8,000
1,152 2,580 4,920 8,940 20,120
8,500
1,224 2,741 5,228 9,499 21,378
9,000
1,296 2,903 5,535 10,058 22,635
9,500
1,368 3,064 5,843 10,616 23,893
10,000
1,440 3,225 6,150 11,175 26,150
NOTICE
Torque values are rounded to the nearest whole unit.
ENGLISH