Key:

    1.  Pendant and Cable
    2.  Carrying Handle and 

Pendant/Cable Storage

    3.  Hyd. Coupler “B” (retract)
    4.  Hyd. Coupler “A” (advance)
    5.  Hyd. Pressure Gauge
    6.  Relief Valve Adjustment 

Knob

    7.  Relief Valve Adjustment 

Locknut

    8.  Hyd. Reservoir Air Breather 

and Filter

    9.  Hyd. Reservoir Oil Drain/Fill 

Plug

  10.  Oil Level indicator
  11.  Front Cover/Panel
  12.  Cooling Fins
13A.  Cooling Vent (exhaust)
13B.  Cooling Vents (intake)
  14.  Power Cord
  15.  Data Plate
  16.  Support Feet (bottom)
  17.  Support Feet (rear)
  18.  Rear Cover/Panel
  19.  Pendant Storage Pocket 

and Fault Code Decal

  20.  Cord Retaining Pocket 

(4 places)

  21.  Multi-Port Manifolds 

(EP3504T_-M only)

Figure 2, Major Features and Components, E-Series Electric Torque Wrench Pumps

Содержание E-Pulse E Series

Страница 1: ...9 Rev B 07 19 To protect your warranty use only ENERPAC hydraulic oil Models EP3504TB and EP3504TB M EP3504TI and EP3504TI M EP3504TE and EP3504TE M E Series Electric Torque Wrench Pump Instruction Sh...

Страница 2: ...necting Hydraulic Hoses 9 5 3 Disconnecting Hydraulic Hoses 9 5 4 Hydraulic Reservoir 10 5 5 Hydraulic Reservoir Air Breather Filter 10 6 0 FEATURES AND CONTROLS 10 6 1 Carrying Handle 10 6 2 Ventilat...

Страница 3: ...e pressurized hydraulic hoses Escaping oil under pressure can penetrate the skin If oil is injected under the skin see a doctor immediately Do not pressurize disconnected couplers The system operating...

Страница 4: ...h the cord The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances Improper connection of the pump grounding condu...

Страница 5: ...ifications on pump data plate Use of incorrect outlet could damage the motor 1 6 IP Ratings Ingress Protection IEC standard 60529 The pump IP rating is IP54 The pendant IP rating is IP67 Outdoor use i...

Страница 6: ...i bar in min l min in min l min in min l min in min l min RPM EP3504T_ 2 Stage 10 000 700 220 3 61 130 2 13 58 0 95 32 0 52 600 2400 EP3504T_ M 2 Stage 10 000 700 220 3 61 130 2 13 58 0 95 32 0 52 600...

Страница 7: ...SSURE 0 100 300 200 400 600 500 700 0 0 5 1 0 1 5 2 5 2 0 3 5 3 0 4 0 Oil flow l min Pressure bar METRIC Models EP3504TI EP3504TI M EP3504TE and EP3504TE M 240V FLOW vs PRESSURE 0 50 100 150 200 250 0...

Страница 8: ...stment Locknut 8 Hyd Reservoir Air Breather and Filter 9 Hyd Reservoir Oil Drain Fill Plug 10 Oil Level indicator 11 Front Cover Panel 12 Cooling Fins 13A Cooling Vent exhaust 13B Cooling Vents intake...

Страница 9: ...bending hoses Do not exceed the hose manufacturer s stated minimum bend radius If a hose becomes kinked or otherwise damaged it must be replaced Damaged hoses may rupture at high pressure Serious pers...

Страница 10: ...nal voltage of 200 250 VAC These units contain a European style Schuko power plug All configurations are single phase 50 60 Hz Before connecting electrical power to the pump be certain that the AC pow...

Страница 11: ...ing Positions NOT ALLOWED 7 3 Air Removal When the torque wrench is connected for the first time air may be trapped in the wrench and hoses To ensure smooth safe operation run the torque wrench throug...

Страница 12: ...he desired pressure 7 Release the green pendant button 8 Recheck the final pressure setting by holding the green pendant button and pressurizing the system 9 If the final pressure setting is not at th...

Страница 13: ...stored pressure is recorded NOTICE The pump will save the stored pressure within the available range of 1 000 to 10 000 psi 70 to 700 bar even after long periods of non use 9 2 Torquing Manual Mode 1...

Страница 14: ...4 Figure 8 Oil Level Indicator FULL ADD OIL See figures 9 and 10 OVERFILLED 11 3 Adding Oil 1 Be sure that hydraulic torque wrench is fully retracted 2 Be certain that pump is off and that all hydrau...

Страница 15: ...applicable laws and regulations 7 Remove the oil drain fill plug Allow all used oil to drain completely from the reservoir into the pan or container It may be necessary to tilt the pump slightly forw...

Страница 16: ...pump side surfaces to remove any accumulated dust or dirt Remove any dust or dirt from the pump front and rear covers and the pump top and bottom surfaces Be sure that all four air vents are unobstru...

Страница 17: ...ration is smooth Refer to Section 7 3 b External hydraulic leak Tighten connections Replace damaged components c Internal leakage in valve Contact Enerpac Authorized Service Center d Internal damage t...

Страница 18: ...pproximately 3 seconds after power has been reconnected This indicates that the pump is in normal operational mode b Pump electrical and or mechanical problems Contact Enerpac Authorized Service Cente...

Страница 19: ...lowed by a 1 second pause Sequence repeats until pump cools to an acceptable temperature Motor electrical or internal ambient temperature too high Allow time for pump temperature to decrease as requir...

Страница 20: ...and or in a sequence Refer to sections 8 0 and 9 0 of this manual for detailed instructions Pump must be connected to AC power Pendant buttons are not functional when AC power is disconnected Activat...

Страница 21: ...Notes 21...

Страница 22: ...Notes 22...

Страница 23: ...Notes 23...

Страница 24: ...http www enerpac com...

Отзывы: